-
1
-
-
84887198076
-
-
U.S. Department of Health and Human Service
-
U.S. Department of Health and Human Service: http://www.4woman.gov/whw
-
-
-
-
2
-
-
0035339809
-
Beyond randomized controlled trials: Organized mammographic screening substantially reduces breast carcinoma mortality
-
Tabar, L., Vitak, B., Chen, H., Yen, M., Duffy, S. W., Smith, R. A., Beyond randomized controlled trials: organized mammographic screening substantially reduces breast carcinoma mortality. Cancer, Vol. 91, No. 9, pp. 1724-31, 2001
-
(2001)
Cancer
, vol.91
, Issue.9
, pp. 1724-1731
-
-
Tabar, L.1
Vitak, B.2
Chen, H.3
Yen, M.4
Duffy, S.W.5
Smith, R.A.6
-
3
-
-
0029005094
-
Efficacy of breast cancer screening by age. New results from the Swedish Two-County Trial
-
Tabar, L., Fagerberg, G., Chen, H., Duffy, S. W., Smart, C. R., Gad, A., Smith, R. A., Efficacy of breast cancer screening by age. New results from the Swedish Two-County Trial, Cancer, Vol. 75, No. 10, pp. 2507-17, 1995
-
(1995)
Cancer
, vol.75
, Issue.10
, pp. 2507-2517
-
-
Tabar, L.1
Fagerberg, G.2
Chen, H.3
Duffy, S.W.4
Smart, C.R.5
Gad, A.6
Smith, R.A.7
-
4
-
-
0033193998
-
Computer-aided diagnosis complements full-field digital mammography
-
Nishikawa, R. M., Computer-aided diagnosis complements full-field digital mammography. Diagnostic Imaging (San Franc), Vol. 21, No. 9, pp. 47-51, 1999
-
(1999)
Diagnostic Imaging (San Franc)
, vol.21
, Issue.9
, pp. 47-51
-
-
Nishikawa, R.M.1
-
5
-
-
0005482571
-
Potential contribution of computer-aided detection to the sensitivity of screening mammography
-
Warren Burhenne, L. J., Wood, S. A., DOrsi, C. J., Feig, S. A., Kopans, D. B., OShaughnessy, K. F., Sickles, E. A., Tabar, L, Vyborny, C. J., Castellino, R. A., Potential contribution of computer-aided detection to the sensitivity of screening mammography. Radiology, Vol. 215, No. 2, pp. 554-62, 2000
-
(2000)
Radiology
, vol.215
, Issue.2
, pp. 554-562
-
-
Warren Burhenne, L.J.1
Wood, S.A.2
Dorsi, C.J.3
Feig, S.A.4
Kopans, D.B.5
Oshaughnessy, K.F.6
Sickles, E.A.7
Tabar, L.8
Vyborny, C.J.9
Castellino, R.A.10
-
6
-
-
0035114759
-
Comparison of full-field digital mammography with screen-film mammography for cancer detection: Results of 4 945 paired examinations
-
Lewin, J. M., Hendrick, R. E., DOrsi, C. J., Isaacs, P. K., Moss, L. J., Karellas, A., Sisney, G. A., Kuni, C. C., Cutter, G. R., Comparison of full-field digital mammography with screen-film mammography for cancer detection: results of 4,945 paired examinations. Radiology, Vol. 218, No. 3, pp. 873-80, 2001
-
(2001)
Radiology
, vol.218
, Issue.3
, pp. 873-880
-
-
Lewin, J.M.1
Hendrick, R.E.2
Dorsi, C.J.3
Isaacs, P.K.4
Moss, L.J.5
Karellas, A.6
Sisney, G.A.7
Kuni, C.C.8
Cutter, G.R.9
-
7
-
-
0003993931
-
-
ed. Washington, D.C.: National Academy Press
-
Nass, S. J., Henderson, C., Lashof, J. C., Mammography and Beyond: Developing Technologies for the Early Detection of Breast Cancer, ed. Washington, D.C.: National Academy Press. 2001
-
(2001)
Mammography and Beyond: Developing Technologies for the Early Detection of Breast Cancer
-
-
Nass, S.J.1
Henderson, C.2
Lashof, J.C.3
-
8
-
-
0035105092
-
Comparison of written reports of mammography, sonography and magnetic resonance mammography for preoperative evaluation of breast lesions, with special emphasis on magnetic resonance mammography
-
Malur, S., Wurdinger, S., Moritz, A., Schneider, A. Comparison of written reports of mammography, sonography and magnetic resonance mammography for preoperative evaluation of breast lesions, with special emphasis on magnetic resonance mammography, Breast Cancer Res., Vol. 3, No. 1, pp. 55-60, 2001
-
(2001)
Breast Cancer Res
, vol.3
, Issue.1
, pp. 55-60
-
-
Malur, S.1
Wurdinger, S.2
Moritz, A.3
Schneider, A.4
-
9
-
-
18644385202
-
Fusion of digital mammography with breast ultrasound - A phantom study
-
San Diego, CA: SPIE
-
Kapur, A., Krucker, J., Astley, O., Buckley, D., Eberhard, J., Alyassin, A., Claus, B., Thomenius, K., Myers, H., Rumsey, M., Johnson, R., Karr, S., Fusion of Digital Mammography with Breast Ultrasound - a Phantom Study, In Medical Imaging 2002: Physics of Medical Imaging. San Diego, CA: SPIE. 2002
-
(2002)
Medical Imaging 2002: Physics of Medical Imaging
-
-
Kapur, A.1
Krucker, J.2
Astley, O.3
Buckley, D.4
Eberhard, J.5
Alyassin, A.6
Claus, B.7
Thomenius, K.8
Myers, H.9
Rumsey, M.10
Johnson, R.11
Karr, S.12
-
10
-
-
84887156925
-
-
46th AAPM Annual Meeting, July 25th - 29th
-
Elbakri, I., Entrekin, R., Coad, C., Danielson, T., Janer, R., Integrated Full-Field Digital Mammography and 3-D Breast Ultrasound System, 46th AAPM Annual Meeting, July 25th - 29th, 2004
-
(2004)
Integrated Full-Field Digital Mammography and 3-D Breast Ultrasound System
-
-
Elbakri, I.1
Entrekin, R.2
Coad, C.3
Danielson, T.4
Janer, R.5
-
11
-
-
13244258001
-
Integrated x-ray and ultrasound breast imaging using fischer. Imagings senoscan full field digital mammography scanner
-
Elbakri, I., EntrekinR., Coad, C., Danielson, T., Suri, J. S., Janer, R., Integrated X-ray and Ultrasound Breast Imaging Using Fischer Imagings SenoScan Full Field Digital Mammography Scanner, Radiological Society of North America, 2004
-
(2004)
Radiological Society of North America
-
-
Elbakri, I.1
Entrekin, R.2
Coad, C.3
Danielson, T.4
Suri, J.S.5
Janer, R.6
-
12
-
-
84887136672
-
-
Winnipeg, Manitoba, Canada
-
Suri, J. S., Guo, Y., Coad, C., Elbakri, I., Entrekin, R., Kwan, A., Boone, J., Janer, R., Image Quality Assessment of Fused Full Field Digital Mammography and Ultrasound Imaging System (FFDMUS), Workshop on Alternatives to Mammography, September 18th - 20th, 2004, Winnipeg, Manitoba, Canada
-
(2004)
Image Quality Assessment of Fused Full Field Digital Mammography and Ultrasound Imaging System (FFDMUS) Workshop on Alternatives to Mammography September 18th - 20th
-
-
Suri, J.S.1
Guo, Y.2
Coad, C.3
Elbakri, I.4
Entrekin, R.5
Kwan, A.6
Boone, J.7
Janer, R.8
-
13
-
-
84887133445
-
-
http://www.cirsinc.com/productlist.html
-
-
-
-
14
-
-
85024963861
-
Comparison of ultrasound quality assurance phantom measurements from matched and mixed scanner-transducer combinations
-
Tradup, D.J., N.J. Hangiandreou, and J.P. Taubel, Comparison of ultrasound quality assurance phantom measurements from matched and mixed scanner-transducer combinations. J Appl Clin Med Phys, 2003. 4(3): p. 239-47
-
(2003)
J Appl Clin Med Phys
, vol.4
, Issue.3
, pp. 239-247
-
-
Tradup, D.J.1
Hangiandreou, N.J.2
Taubel, J.P.3
-
15
-
-
0034984493
-
A review of two alternative ultrasound quality assurance programmes
-
Dudley, N.J., et al., A review of two alternative ultrasound quality assurance programmes. Eur J Ultrasound, 2001. 12(3): p. 233-45
-
(2001)
Eur J Ultrasound
, vol.12
, Issue.3
, pp. 233-245
-
-
Dudley, N.J.1
-
16
-
-
0031860480
-
Comparison of selected ultrasound performance tests with varying overall receiver gain and dynamic range
-
Kanal, K.M., J.M. Kofler, and D.S. Groth, Comparison of selected ultrasound performance tests with varying overall receiver gain and dynamic range, using conventional and magnified field of view. Med Phys, 1998. 25(5): p. 642-7
-
(1998)
Using Conventional and Magnified Field of View. Med Phys
, vol.25
, Issue.5
, pp. 642-647
-
-
Kanal, K.M.1
Kofler, J.M.2
Groth, D.S.3
-
17
-
-
0029678316
-
QA in the vascular ultrasound lab
-
Burke, E., QA in the vascular ultrasound lab. Radiol Technol, 1996. 67(3): p. 253-6
-
(1996)
Radiol Technol
, vol.67
, Issue.3
, pp. 253-256
-
-
Burke, E.1
-
18
-
-
0028525359
-
Functional properties of diagnostic ultrasound instruments. A concept of trial building blocks for implementing quality assurance
-
Trier H.G. [Functional properties of diagnostic ultrasound instruments. A concept of trial building blocks for implementing quality assurance]. Ultraschall Med 1994 15(5)223-32.
-
(1994)
Ultraschall Med
, vol.15
, Issue.5
, pp. 223-232
-
-
Trier, H.G.1
-
19
-
-
0027451108
-
Quality assurance of ultrasound imaging instruments by monitoring the monitor
-
Walker, J.B., G.C. Thorne, and M. Halliwell, Quality assurance of ultrasound imaging instruments by monitoring the monitor. Phys Med Biol, 1993. 38(11): p. 1601-9
-
(1993)
Phys Med Biol
, vol.38
, Issue.11
, pp. 1601-1609
-
-
Walker, J.B.1
Thorne, G.C.2
Halliwell, M.3
-
20
-
-
0027208783
-
Routine quality assurance of high frequency ultrasound breast scanners in a screening context
-
Evans, J.A., et al., Routine quality assurance of high frequency ultrasound breast scanners in a screening context. Br J Radiol, 1993. 66(787): p. 614-8
-
(1993)
Br J Radiol
, vol.66
, Issue.787
, pp. 614-618
-
-
Evans, J.A.1
-
21
-
-
0026708576
-
A study of the relationship between routine ultrasound quality assurance parameters and subjective operator image assessment
-
Metcalfe, S.C. and J.A. Evans, A study of the relationship between routine ultrasound quality assurance parameters and subjective operator image assessment. Br J Radiol, 1992. 65(775): p. 570-5
-
(1992)
Br J Radiol
, vol.65
, Issue.775
, pp. 570-575
-
-
Metcalfe, S.C.1
Evans, J.A.2
-
22
-
-
84887211000
-
-
Patent US 5
-
Madsen, E., Zagzebski, J., Frank, G., Rownd, J., Automated system and method for testing resolution of ultrasound scanners. Patent US 5,574,212, 1996
-
(1996)
Automated System and Method for Testing Resolution of Ultrasound Scanners
, vol.574
, pp. 212
-
-
Madsen, E.1
Zagzebski, J.2
Frank, G.3
Rownd, J.4
-
23
-
-
0018306059
-
A threshold selection method from gray level histograms
-
March
-
Otsu, N., A threshold selection method from gray level histograms. IEEE Trans. Systems, Man and Cybernetics, Vol. 9, pp. 62-66, March 1979
-
(1979)
IEEE Trans. Systems Man and Cybernetics
, vol.9
, pp. 62-66
-
-
Otsu, N.1
-
25
-
-
0026837927
-
A simple method for determining the modulation transfer function in digital radiography
-
H Fujita et al. A simple method for determining the modulation transfer function in digital radiography. IEEE Trans. Med. Imaging, 11(1):34-39, 1992
-
(1992)
IEEE Trans. Med. Imaging
, vol.11
, Issue.1
, pp. 34-39
-
-
Fujita, H.1
-
26
-
-
34250090755
-
Active contour models
-
Kass, M., Witkin, A., Terzopoulos, D. Snakes: Active contour models, Int. J. Comput. Vis., Vol. 1, pp. 321-331, 1987
-
(1987)
Int. J. Comput. Vis
, vol.1
, pp. 321-331
-
-
Kass, M.1
Witkin, A.2
Snakes, T.D.3
-
27
-
-
0035214682
-
Accurate segmentation of the breast region from digitized mammograms
-
Ojala, T., Näppi, J., Nevalainen, O., Accurate segmentation of the breast region from digitized mammograms, Computerized Medical Imaging and Graphics, Vol. 25, pp. 47-59, 2001
-
(2001)
Computerized Medical Imaging and Graphics
, vol.25
, pp. 47-59
-
-
Ojala, T.1
Näppi, J.2
Nevalainen, O.3
-
28
-
-
4544379631
-
-
Wirth, M. A., Stapinski, A., Segmentation of the Breast Region in Mammograms Using Snakes, 1st Canadian Conference on Computer and Robot Vision (CRV04), pp. 385-392, 2004
-
(2004)
Segmentation of the Breast Region in Mammograms Using Snakes, 1st Canadian Conference on Computer and Robot Vision (CRV04)
, pp. 385-392
-
-
Wirth, M.A.1
Stapinski, A.2
-
29
-
-
0032028944
-
Gradient vector flow
-
Xu, C., Prince, J., Snakes, Shapes, and Gradient Vector Flow, IEEE Transactions on Image Processing, Vol. 7, No. 3, pp. 359-369, 1998
-
(1998)
IEEE Transactions on Image Processing
, vol.7
, Issue.3
, pp. 359-369
-
-
Xu, C.1
Prince, J.2
Shapes, S.3
-
30
-
-
0003935459
-
-
2nd edition, Addision-Wesley
-
Foley, J. D., Van Dam, A. Feiner, S. K., Hughes, J. F., Computer Graphics in C: Principles and Practice, 2nd edition, Addision-Wesley, 1996
-
(1996)
Computer Graphics in C: Principles and Practice
-
-
Foley, J.D.1
Van Dam Feiner, A.S.K.2
Hughes, J.F.3
-
31
-
-
0025465145
-
Scale-space and edge detection using anisotropic diffusion
-
Perona, P., Malik, J., Scale-space and edge detection using anisotropic diffusion, IEEE Trans. In Pattern Analysis and Machine Intelligence, Vol. 12, No. 7, pp. 629-639, 1990
-
(1990)
IEEE Trans in Pattern Analysis and Machine Intelligence
, vol.12
, Issue.7
, pp. 629-639
-
-
Perona, P.1
Malik, J.2
-
32
-
-
13244266637
-
-
Plenum Publishers, ISBN#: 0-306-46678-3
-
Suri, J. S., Laxminarayan, S., PDE & Level Sets: Algorithmic Approaches to Static & Motion Imagery, Kluwer Academic /Plenum Publishers, ISBN#: 0-306-46678-3, 2002
-
(2002)
PDE Level Sets: Algorithmic Approaches to Static & Motion Imagery Kluwer Academic /
-
-
Suri, J.S.1
Laxminarayan, S.2
-
33
-
-
0036489320
-
Shape recovery algorithms using level sets in 2-d/3-d medical imagery: A state-of-the art review
-
Suri, J. S., Liu, K., Laxminarayan, S., Zeng, X., Reden, L., Shape Recovery Algorithms Using Level Sets in 2-D/3-D Medical Imagery: A State-of-the Art Review, IEEE Trans. Info. Tech. in Biomedicine, Vol. 6, No. 1, pp. 8-28, 2002
-
(2002)
IEEE Trans. Info. Tech. in Biomedicine
, vol.6
, Issue.1
, pp. 8-28
-
-
Suri, J.S.1
Liu, K.2
Laxminarayan, S.3
Zeng, X.4
Reden, L.5
-
34
-
-
13244268132
-
Modeling Segmentation via Geometric Deformable Regularizers, PDE and Level Sets in Still and Motion Imagery: A Revisit
-
Suri, J. S., Wu, D., Reden, L., Gao, J., Singh, S., Laxminarayan, S., Modeling Segmentation via Geometric Deformable Regularizers, PDE and Level Sets in Still and Motion Imagery: A Revisit, International Journal of Image and Graphics, Vol. 1, No. 4, pp. 681-734, 2001
-
(2001)
International Journal of Image and Graphics
, vol.1
, Issue.4
, pp. 681-734
-
-
Suri, J.S.1
Wu, D.2
Reden, L.3
Gao, J.4
Singh, S.5
Laxminarayan, S.6
-
35
-
-
84887183330
-
-
Accepted by SPIE
-
Suri, J. S., Guo, Y., Danielson, T., Janer, R., Effect of PDE-based Noise Removal on GVF-based Deformation Model on Lesion Detection in Breast Phantom X-ray Images from Fischers Fused FFDM and Ultrasound (FFDMUS) Imaging System, Accepted by SPIE 2005
-
(2005)
Effect of PDE-based Noise Removal on GVF-based Deformation Model on Lesion Detection in Breast Phantom X-ray Images from Fischer S Fused FFDM and Ultrasound (FFDMUS) Imaging System
-
-
Suri, J.S.1
Guo, Y.2
Danielson, T.3
Janer, R.4
-
36
-
-
0031106962
-
Multimodality image registration by maximization of mutual information
-
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., Suetens, P., Multimodality image registration by maximization of mutual information, IEEE Transactions on Medical Imaging, Vol. 16, No. 2, pp. 187-198, 1997
-
(1997)
IEEE Transactions on Medical Imaging
, vol.16
, Issue.2
, pp. 187-198
-
-
Maes, F.1
Collignon, A.2
Vandermeulen, D.3
Marchal, G.4
Suetens, P.5
-
37
-
-
0030088712
-
Multimodal volume registration by maximization of mutual information
-
Wells, W., Viola, P., Atsumi, H., Nakajima, S., Kikinis, R., Multimodal volume registration by maximization of mutual information, Medical Image Analysis, Vol. 1, No. 1, pp. 35-51, 1996
-
(1996)
Medical Image Analysis
, vol.1
, Issue.1
, pp. 35-51
-
-
Wells, W.1
Viola, P.2
Atsumi, H.3
Nakajima, S.4
Kikinis, R.5
-
38
-
-
0032762144
-
An overlap invariant entropy measure of 3d medical image alignment
-
Studholme, C., Hill, D., Hawkes, D., An overlap invariant entropy measure of 3d medical image alignment, Pattern Recognition, Vol. 32, No. 1, pp. 71-86, 1999
-
(1999)
Pattern Recognition
, vol.32
, Issue.1
, pp. 71-86
-
-
Studholme, C.1
Hill, D.2
Hawkes, D.3
-
39
-
-
0026967479
-
A survey of image registration techniques
-
Dec
-
Brown, L. G., A survey of image registration techniques, ACM Comput. Surv., Vol. 24, pp. 325-376, Dec. 1992
-
(1992)
ACM Comput. Surv
, vol.24
, pp. 325-376
-
-
Brown, L.G.1
-
40
-
-
0003474751
-
-
Cambridge University Press
-
Press, W. H., Flannery, B. P., Teukolsky, S. A., Vetterling, W. T., Numerical Recipes in C, Cambridge University Press, 1988
-
(1988)
Numerical Recipes in C
-
-
Press, W.H.1
Flannery, B.P.2
Teukolsky, S.A.3
Vetterling, W.T.4
-
41
-
-
0031028413
-
Automated 3D registration of MR and PET brain images by multiresolution optimization of voxel similarity measures
-
Studholme, C., Hill, D., Hawkes, D., Automated 3D registration of MR and PET brain images by multiresolution optimization of voxel similarity measures, Medical Physics, Vol. 24, No. 1, pp. 25-36, 1997
-
(1997)
Medical Physics
, vol.24
, Issue.1
, pp. 25-36
-
-
Studholme, C.1
Hill, D.2
Hawkes, D.3
-
42
-
-
0033251944
-
Comparative evaluation of multi-resolution optimization strategies for multimodality image registration by maximization of mutual information
-
Maes, F., Vandermeulen, D., Suetens, P., Comparative evaluation of multi-resolution optimization strategies for multimodality image registration by maximization of mutual information, Medical Image Analysis., Vol. 3, No. 4, pp. 373-386, 1999
-
(1999)
Medical Image Analysis
, vol.3
, Issue.4
, pp. 373-386
-
-
Maes, F.1
Vandermeulen, D.2
Suetens, P.3
-
43
-
-
60849129159
-
A multiscale approach to mutual information matching, Medical Imaging
-
Pluim, J., Maintz, J., Viergever, M., A multiscale approach to mutual information matching, Medical Imaging 1998: Image Processing, SPIE Vol. 3338, pp. 1334-1344, 1998
-
(1998)
Image Processing, SPIE
, vol.3338
, Issue.1998
, pp. 1334-1344
-
-
Pluim, J.1
Maintz, J.2
Viergever, M.3
-
44
-
-
0032785812
-
A survey of hierarchical non-linear medical image registration
-
Lester, H., Arridge, S. R., A survey of hierarchical non-linear medical image registration, Pattern Recogn., Vol. 32, No. 1, pp. 129-149, 1999
-
(1999)
Pattern Recogn
, vol.32
, Issue.1
, pp. 129-149
-
-
Lester, H.1
Arridge, S.R.2
|