메뉴 건너뛰기




Volumn 112, Issue 1, 2006, Pages 1-11

Pattern reversal ERG and VEP - Comparison of stimulation by LED, monitor and a Maxwellian-view system

Author keywords

Checkerboard reversal; LED; Maxwellian view system; Monitor; PERG; VEP

Indexed keywords

XENON;

EID: 33745438405     PISSN: 00124486     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10633-005-5865-z     Document Type: Article
Times cited : (11)

References (30)
  • 1
    • 0027604622 scopus 로고
    • Pattern electroretinogram and computerized optic nerve-head analysis in glaucoma suspects
    • 1:STN:280:ByyA38nps1U%3D 8334394
    • M Bach J Funk 1993 Pattern electroretinogram and computerized optic nerve-head analysis in glaucoma suspects Ger J Ophthalmol 2 3 178-81 1:STN:280:ByyA38nps1U%3D 8334394
    • (1993) Ger J Ophthalmol , vol.2 , Issue.3 , pp. 178-181
    • Bach, M.1    Funk, J.2
  • 2
    • 0031393229 scopus 로고    scopus 로고
    • Little correlation of the pattern electroretinogram (PERG) and visual field measures in early glaucoma
    • M Bach F Sulimma J Gerling 1997-1998 Little correlation of the pattern electroretinogram (PERG) and visual field measures in early glaucoma Doc Ophthalmol 94 3 253-63
    • (1997) Doc Ophthalmol , vol.94 , Issue.3 , pp. 253-263
    • Bach, M.1    Sulimma, F.2    Gerling, J.3
  • 3
    • 0027460524 scopus 로고
    • Predictive value of the pattern electroretinogram in high-risk ocular hypertension
    • 1:STN:280:ByyB3s7ns1Q%3D 8473110
    • N Pfeiffer B Tillmon M Bach 1993 Predictive value of the pattern electroretinogram in high-risk ocular hypertension Invest Ophthalmol Vis Sci 34 5 1710-5 1:STN:280:ByyB3s7ns1Q%3D 8473110
    • (1993) Invest Ophthalmol Vis Sci , vol.34 , Issue.5 , pp. 1710-1715
    • Pfeiffer, N.1    Tillmon, B.2    Bach, M.3
  • 4
    • 0034765702 scopus 로고    scopus 로고
    • Electrophysiological approaches for early detection of glaucoma
    • 11592530
    • M Bach 2001 Electrophysiological approaches for early detection of glaucoma Eur J Ophthalmol 11 Suppl 2 S41-9 11592530
    • (2001) Eur J Ophthalmol , vol.11 , Issue.SUPPL. 2
    • Bach, M.1
  • 5
    • 0242352552 scopus 로고    scopus 로고
    • The multifocal pattern electroretinogram in glaucoma
    • 10.1016/j.visres.2003.08.012 14599576
    • S Stiefelmeyer AS Neubauer T Berninger GB Arden G Rudolph 2004 The multifocal pattern electroretinogram in glaucoma Vision Res 44 1 103-12 10.1016/j.visres.2003.08.012 14599576
    • (2004) Vision Res , vol.44 , Issue.1 , pp. 103-112
    • Stiefelmeyer, S.1    Neubauer, A.S.2    Berninger, T.3    Arden, G.B.4    Rudolph, G.5
  • 6
    • 9944253774 scopus 로고    scopus 로고
    • Electrophysiological assessment of optic nerve disease
    • 10.1038/sj.eye.6701573 1:STN:280:DC%2BD2crmtFOhsQ%3D%3D 15534599
    • GE Holder 2004 Electrophysiological assessment of optic nerve disease Eye 18 11 1133-43 10.1038/sj.eye.6701573 1:STN:280:DC%2BD2crmtFOhsQ%3D%3D 15534599
    • (2004) Eye , vol.18 , Issue.11 , pp. 1133-1143
    • Holder, G.E.1
  • 7
    • 1842739514 scopus 로고    scopus 로고
    • Built-in LED contact lens electrode for S-cone electroretinographic recordings
    • 10.1023/B:DOOP.0000018396.16150.1e 15104168
    • M Tsuruoka S Yamamoto K Ogata M Hayashi 2004 Built-in LED contact lens electrode for S-cone electroretinographic recordings Doc Ophthalmol 108 1 61-6 10.1023/B:DOOP.0000018396.16150.1e 15104168
    • (2004) Doc Ophthalmol , vol.108 , Issue.1 , pp. 61-66
    • Tsuruoka, M.1    Yamamoto, S.2    Ogata, K.3    Hayashi, M.4
  • 8
    • 0037405989 scopus 로고    scopus 로고
    • Electroretinography of short-wavelength-sensitive cones with a LED built-in electrode and its normal values
    • 10.1023/A:1022930709585 12737509
    • K Kuniyoshi N Uno M Irifune Y Shimomura 2003 Electroretinography of short-wavelength-sensitive cones with a LED built-in electrode and its normal values Doc Ophthalmol 106 3 311-8 10.1023/A:1022930709585 12737509
    • (2003) Doc Ophthalmol , vol.106 , Issue.3 , pp. 311-318
    • Kuniyoshi, K.1    Uno, N.2    Irifune, M.3    Shimomura, Y.4
  • 9
    • 0038302253 scopus 로고    scopus 로고
    • Cyclic summation versus m-sequence technique in the multifocal ERG
    • 10.1007/s00417-002-0608-2 12756575
    • T Lindenberg FK Horn M Korth 2003 Cyclic summation versus m-sequence technique in the multifocal ERG Graefes Arch Clin Exp Ophthalmol 241 6 505-10 10.1007/s00417-002-0608-2 12756575
    • (2003) Graefes Arch Clin Exp Ophthalmol , vol.241 , Issue.6 , pp. 505-510
    • Lindenberg, T.1    Horn, F.K.2    Korth, M.3
  • 10
    • 33745457920 scopus 로고    scopus 로고
    • An examination of local ON- and OFF-system responses in patients with progressive cone dystrophy using long duration LED stimulation
    • ARVO (Abstract #5151)
    • Holopigian K, Wynn P, Clemens CJ, Seiple W, Carr RE and Hood DC. An examination of local ON- and OFF-system responses in patients with progressive cone dystrophy using long duration LED stimulation. ARVO 2004 (Abstract #5151).
    • (2004)
    • Holopigian, K.1    Wynn, P.2    Clemens, C.J.3    Seiple, W.4    Carr, R.E.5    Hood, D.C.6
  • 11
    • 33745462990 scopus 로고    scopus 로고
    • Flash visual evoked potentials in healthy volunteers and patients using the RETIscan LED-Goggles
    • ARVO Abstract
    • Bueltmann S, Weimer P, and Rohrschneider K. Flash visual evoked potentials in healthy volunteers and patients using the RETIscan LED-Goggles. ARVO Abstract 2004.
    • (2004)
    • Bueltmann, S.1    Weimer, P.2    Rohrschneider, K.3
  • 12
    • 0028603558 scopus 로고
    • Differences between pattern-evoked electroretinograms obtained by a scanning laser ophthalmoscope and by a mechanical mirror system
    • 10.1007/BF01203703 1:STN:280:ByqB283lsVc%3D 7743914
    • F Horn M Korth 1994 Differences between pattern-evoked electroretinograms obtained by a scanning laser ophthalmoscope and by a mechanical mirror system Doc Ophthalmol 88 1 65-75 10.1007/BF01203703 1:STN:280:ByqB283lsVc%3D 7743914
    • (1994) Doc Ophthalmol , vol.88 , Issue.1 , pp. 65-75
    • Horn, F.1    Korth, M.2
  • 13
    • 0036866732 scopus 로고    scopus 로고
    • The influence of ambient room lighting on the pattern electroretinogram (PERG)
    • 10.1023/A:1021254427782 12539853
    • M Bach M Schumacher 2002 The influence of ambient room lighting on the pattern electroretinogram (PERG) Doc Ophthalmol 105 3 281-9 10.1023/ A:1021254427782 12539853
    • (2002) Doc Ophthalmol , vol.105 , Issue.3 , pp. 281-289
    • Bach, M.1    Schumacher, M.2
  • 15
    • 0033652880 scopus 로고    scopus 로고
    • Standard for pattern electroretinography
    • 10.1023/A:1002732114721 1:STN:280:DC%2BD3M%2Fps1Glsw%3D%3D 11128964
    • M Bach M Hawlin GE Holder MF Marmor T Meigen Y Miyake 2000 Standard for pattern electroretinography Doc Ophthalmol 101 11-8 10.1023/ A:1002732114721 1:STN:280:DC%2BD3M%2Fps1Glsw%3D%3D 11128964
    • (2000) Doc Ophthalmol , vol.101 , pp. 11-18
    • Bach, M.1    Hawlin, M.2    Holder, G.E.3    Marmor, M.F.4    Meigen, T.5    Miyake, Y.6
  • 16
    • 1842739486 scopus 로고    scopus 로고
    • Performance of the DTL electrode compared to the Jet contact lens electrode in clinical testing
    • 10.1023/B:DOOP.0000018395.78512.4e 15104170
    • H Yin MT Pardue 2004 Performance of the DTL electrode compared to the Jet contact lens electrode in clinical testing Doc Ophthalmol 108 77-86 10.1023/B:DOOP.0000018395.78512.4e 15104170
    • (2004) Doc Ophthalmol , vol.108 , pp. 77-86
    • Yin, H.1    Pardue, M.T.2
  • 18
    • 0020373187 scopus 로고
    • Spatial and temporal frequency tuning of pattern-reversal retinal potentials
    • 1:STN:280:BiyD2MnhsVc%3D 7141818
    • GL Trick DH Wintermeyer 1982 Spatial and temporal frequency tuning of pattern-reversal retinal potentials Invest Ophthalmol Vis Sci 23 6 774-9 1:STN:280:BiyD2MnhsVc%3D 7141818
    • (1982) Invest Ophthalmol Vis Sci , vol.23 , Issue.6 , pp. 774-779
    • Trick, G.L.1    Wintermeyer, D.H.2
  • 19
    • 0022411430 scopus 로고
    • Spatial tuning of the pattern ERG across temporal frequency
    • 10.1007/BF00143211 1:STN:280:BimD2Mris1A%3D 4064886
    • T Berninger RP Schuurmans 1985 Spatial tuning of the pattern ERG across temporal frequency Doc Ophthalmol 61 1 17-25 10.1007/BF00143211 1:STN:280:BimD2Mris1A%3D 4064886
    • (1985) Doc Ophthalmol , vol.61 , Issue.1 , pp. 17-25
    • Berninger, T.1    Schuurmans, R.P.2
  • 20
    • 0020403386 scopus 로고
    • Pattern evoked retinal response (PERR) in human: Effects of spatial frequency, temporal frequency, luminance and defocus
    • JV Odom TM Maida WW Dawson 1982-1983 Pattern evoked retinal response (PERR) in human: Effects of spatial frequency, temporal frequency, luminance and defocus Curr Eye Res 2 2 99-108
    • (1982) Curr Eye Res , vol.2 , Issue.2 , pp. 99-108
    • Odom, J.V.1    Maida, T.M.2    Dawson, W.W.3
  • 21
    • 0027521106 scopus 로고    scopus 로고
    • Interactions of spectral, spatial, and temporal mechanisms in the human pattern visual evoked potential
    • M Korth NX Nguyen R Rix O Sembritzki 1999 Interactions of spectral, spatial, and temporal mechanisms in the human pattern visual evoked potential Vision Res 33 17 2397-411
    • (1999) Vision Res , vol.33 , Issue.17 , pp. 2397-2411
    • Korth, M.1    Nguyen, N.X.2    Rix, R.3    Sembritzki, O.4
  • 22
    • 0024408876 scopus 로고
    • Pattern reversal electroretinogram - Effect of check size, luminance, field size and defocusing
    • [Article in Japanese] 1:STN:280:By%2BD383psFU%3D 2801364
    • M Yoshii K Yanashima S Okisaka 1989 Pattern reversal electroretinogram - effect of check size, luminance, field size and defocusing [Article in Japanese] Nippon Ganka Gakkai Zasshi 93 5 610-6 1:STN:280:By%2BD383psFU%3D 2801364
    • (1989) Nippon Ganka Gakkai Zasshi , vol.93 , Issue.5 , pp. 610-616
    • Yoshii, M.1    Yanashima, K.2    Okisaka, S.3
  • 24
    • 0018671432 scopus 로고
    • True checkerboard pattern reversal with light-emitting diodes
    • 1:STN:280:Bi%2BD2cnktVE%3D 91489
    • CM Epstein 1979 True checkerboard pattern reversal with light-emitting diodes Electroencephalogr Clin Neurophysiol 47 5 611-3 1:STN:280:Bi%2BD2cnktVE%3D 91489
    • (1979) Electroencephalogr Clin Neurophysiol , vol.47 , Issue.5 , pp. 611-613
    • Epstein, C.M.1
  • 25
    • 0018147142 scopus 로고
    • Visual evoked responses in multiple sclerosis: Comparison of two methods for pattern reversal
    • 1:STN:280:CSeB3MbptVE%3D 671061
    • BY Nilsson 1978 Visual evoked responses in multiple sclerosis: comparison of two methods for pattern reversal J Neurol Neurosurg Psychiatry 41 6 499-504 1:STN:280:CSeB3MbptVE%3D 671061
    • (1978) J Neurol Neurosurg Psychiatry , vol.41 , Issue.6 , pp. 499-504
    • Nilsson, B.Y.1
  • 26
    • 0021958395 scopus 로고
    • Flash and pattern presentation and pattern-reversal evoked potentials in multiple sclerosis
    • 10.1007/BF00160609 1:STN:280:BiqB3czjs1I%3D 3996188
    • J Czopf 1985 Flash and pattern presentation and pattern-reversal evoked potentials in multiple sclerosis Doc Ophthalmol 59 2 129-41 10.1007/ BF00160609 1:STN:280:BiqB3czjs1I%3D 3996188
    • (1985) Doc Ophthalmol , vol.59 , Issue.2 , pp. 129-141
    • Czopf, J.1
  • 27
    • 0021246724 scopus 로고
    • Reproducibility of the visual evoked potential using a light-emitting diode stimulator
    • 1:STN:280:BiuB2c7os1c%3D 6736996
    • NF Skuse D Burke B McKeon 1984 Reproducibility of the visual evoked potential using a light-emitting diode stimulator J Neurol Neurosurg Psychiatry 47 6 623-9 1:STN:280:BiuB2c7os1c%3D 6736996
    • (1984) J Neurol Neurosurg Psychiatry , vol.47 , Issue.6 , pp. 623-629
    • Skuse, N.F.1    Burke, D.2    McKeon, B.3
  • 28
    • 0141757142 scopus 로고    scopus 로고
    • Baseline characteristics of the transient pattern electroretinogram in non-human primates: Inter-ocular and inter-session variability
    • 10.1016/S0014-4835(03)00195-7 1:CAS:528:DC%2BD3sXnvVyksbo%3D 14550397
    • BV Bui B Fortune G Cull L Wang GA Cioffi 2003 Baseline characteristics of the transient pattern electroretinogram in non-human primates: inter-ocular and inter-session variability Exp Eye Res 77 5 555-66 10.1016/S0014-4835(03)00195-7 1:CAS:528:DC%2BD3sXnvVyksbo%3D 14550397
    • (2003) Exp Eye Res , vol.77 , Issue.5 , pp. 555-566
    • Bui, B.V.1    Fortune, B.2    Cull, G.3    Wang, L.4    Cioffi, G.A.5
  • 29
    • 0022404024 scopus 로고
    • Retinal potentials in patients with primary open-angle glaucoma: Physiological evidence for temporal frequency tuning deficits
    • 1:STN:280:BimD2Mfks1A%3D 4066211
    • GL Trick 1985 Retinal potentials in patients with primary open-angle glaucoma: Physiological evidence for temporal frequency tuning deficits Invest Ophthalmol Vis Sci 26 1750-8 1:STN:280:BimD2Mfks1A%3D 4066211
    • (1985) Invest Ophthalmol Vis Sci , vol.26 , pp. 1750-1758
    • Trick, G.L.1
  • 30
    • 0026061907 scopus 로고
    • Effect of decreased retinal illumination on simultaneously recorded pattern electroretinograms and visual-evoked potentials
    • 1:STN:280:By6C3s7ivFc%3D 1993582
    • J Froehlich DI Kaufman 1991 Effect of decreased retinal illumination on simultaneously recorded pattern electroretinograms and visual-evoked potentials Invest Ophthalmol Vis Sci 32 310-8 1:STN:280:By6C3s7ivFc%3D 1993582
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 310-318
    • Froehlich, J.1    Kaufman, D.I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.