메뉴 건너뛰기




Volumn 85, Issue 7, 2006, Pages 553-558

Three types of skin-surface thermometers: A comparison of reliability, validity, and responsiveness

Author keywords

Infrared; Reliability; Responsiveness; Skin; Temperature; Validity

Indexed keywords

ADULT; ARTICLE; BODY TEMPERATURE MEASUREMENT; CALCULATION; COMPLEX REGIONAL PAIN SYNDROME; CORRELATION ANALYSIS; EVALUATION; FEMALE; FOOT; FOREARM; HAND; HUMAN; HUMAN EXPERIMENT; INFRARED THERMOMETER; LEG; MALE; NORMAL HUMAN; SHOULDER; SKIN SURFACE; SYMPATHETIC BLOCKING; TEST RETEST RELIABILITY; THERMISTOR; THERMOMETER; THIGH; TYMPANIC TEMPERATURE; VALIDITY;

EID: 33745416116     PISSN: 08949115     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.phm.0000223232.32653.7f     Document Type: Article
Times cited : (73)

References (19)
  • 1
    • 0034055805 scopus 로고    scopus 로고
    • Neurologic findings in complex regional pain syndromes: Analysis of 145 cases
    • Birklein F: Neurologic findings in complex regional pain syndromes: Analysis of 145 cases. Acta Neurol Scand 2000;101:262-9
    • (2000) Acta Neurol Scand , vol.101 , pp. 262-269
    • Birklein, F.1
  • 2
    • 7444253297 scopus 로고    scopus 로고
    • Home monitoring of foot skin temperature to prevent ulceration
    • Lavery LA: Home monitoring of foot skin temperature to prevent ulceration. Diabetes Care 2004;27:2642-7
    • (2004) Diabetes Care , vol.27 , pp. 2642-2647
    • Lavery, L.A.1
  • 3
    • 1342316892 scopus 로고    scopus 로고
    • Skin temperature and chronic venous insufficiency
    • Kelechi TJ: Skin temperature and chronic venous insufficiency. J Vasc Nurs 2003;21:98-105
    • (2003) J Vasc Nurs , vol.21 , pp. 98-105
    • Kelechi, T.J.1
  • 4
    • 0036461058 scopus 로고    scopus 로고
    • Cold-stress tests involving finger skin temperature measurement for evaluation of vascular disorders in hand-arm vibration syndrome: Review of the literature
    • Harada N: Cold-stress tests involving finger skin temperature measurement for evaluation of vascular disorders in hand-arm vibration syndrome: Review of the literature. Int Arch Occup Environ Health 2002;75:14-9
    • (2002) Int Arch Occup Environ Health , vol.75 , pp. 14-19
    • Harada, N.1
  • 5
    • 0028354173 scopus 로고
    • Susceptibility to decubitus ulcer formation
    • Meijer JH: Susceptibility to decubitus ulcer formation. Arch Phys Med Rehabil 1994;75:318-23
    • (1994) Arch Phys Med Rehabil , vol.75 , pp. 318-323
    • Meijer, J.H.1
  • 6
    • 0015108568 scopus 로고
    • Normal sensory conduction in the nerves of the legs in man
    • Behse F, Buchthal F: Normal sensory conduction in the nerves of the legs in man. J Neurol Neurosurg Psychiatry 1971;34:404-14
    • (1971) J Neurol Neurosurg Psychiatry , vol.34 , pp. 404-414
    • Behse, F.1    Buchthal, F.2
  • 7
    • 0015730220 scopus 로고
    • The effects of cold on nerve conduction of slow and fast nerve fibers
    • DeJesus PV, Hausmanowa-Petrusewicz I, Barchi RL: The effects of cold on nerve conduction of slow and fast nerve fibers. Neurology 1973;23:1182-9
    • (1973) Neurology , vol.23 , pp. 1182-1189
    • DeJesus, P.V.1    Hausmanowa-Petrusewicz, I.2    Barchi, R.L.3
  • 8
    • 0018879086 scopus 로고
    • Nerve conduction velocity: Relationship of skin, subcutaneous and intramuscular temperatures
    • Halar E, DeLisa JL, Brozovich FV: Nerve conduction velocity: relationship of skin, subcutaneous and intramuscular temperatures. Arch Phys Med Rehabil 1980;61:199-203
    • (1980) Arch Phys Med Rehabil , vol.61 , pp. 199-203
    • Halar, E.1    DeLisa, J.L.2    Brozovich, F.V.3
  • 9
    • 0034968531 scopus 로고    scopus 로고
    • The effects of temperature in neuromuscular electrophysiology
    • Rutkove SB: The effects of temperature in neuromuscular electrophysiology. Muscle Nerve 2001;24:867-82
    • (2001) Muscle Nerve , vol.24 , pp. 867-882
    • Rutkove, S.B.1
  • 10
    • 0029143317 scopus 로고
    • Reliability and validity of tympanic temperature measurements in persons with high spinal cord injuries
    • Chu A, Burnham RS: Reliability and validity of tympanic temperature measurements in persons with high spinal cord injuries. Paraplegia 1995;33:476-9
    • (1995) Paraplegia , vol.33 , pp. 476-479
    • Chu, A.1    Burnham, R.S.2
  • 11
    • 0031752641 scopus 로고    scopus 로고
    • Oesophageal, rectal, axillary, tympanic and pulmonary temperatures during cardiac surgery
    • Robinson J, Charlton J, Seal R, et al: Oesophageal, rectal, axillary, tympanic and pulmonary temperatures during cardiac surgery. Can J Anaesth 1998;45:317-23
    • (1998) Can J Anaesth , vol.45 , pp. 317-323
    • Robinson, J.1    Charlton, J.2    Seal, R.3
  • 12
    • 0023919481 scopus 로고
    • Infrared tympanic thermometer: Evaluation of a new clinical thermometer
    • Shinozaki T, Deane R, Perkins F: Infrared tympanic thermometer: Evaluation of a new clinical thermometer. Crit Care Med 1988;16:148-50
    • (1988) Crit Care Med , vol.16 , pp. 148-150
    • Shinozaki, T.1    Deane, R.2    Perkins, F.3
  • 13
    • 0037771454 scopus 로고    scopus 로고
    • Bladder temperature versus tympanic membrane and forehead skin temperature
    • Joost M: Bladder temperature versus tympanic membrane and forehead skin temperature. Ugeskr Laeger 2003;165:2296-8
    • (2003) Ugeskr Laeger , vol.165 , pp. 2296-2298
    • Joost, M.1
  • 14
    • 0034007678 scopus 로고    scopus 로고
    • Comparison of infrared thermometer with thermocouple for monitoring skin temperature
    • Matsukawa T, Ozaki M, Nishiyama T, et al: Comparison of infrared thermometer with thermocouple for monitoring skin temperature. Crit Care Med 2000;28:532-6
    • (2000) Crit Care Med , vol.28 , pp. 532-536
    • Matsukawa, T.1    Ozaki, M.2    Nishiyama, T.3
  • 15
    • 0023154612 scopus 로고
    • Measuring change over time: Assessing the usefulness of evaluative instruments
    • Guyatt G, Walter S, Norman G: Measuring change over time: Assessing the usefulness of evaluative instruments. J Chron Dis 1987;40:171-8
    • (1987) J Chron Dis , vol.40 , pp. 171-178
    • Guyatt, G.1    Walter, S.2    Norman, G.3
  • 16
    • 0030435698 scopus 로고    scopus 로고
    • The challenge of measuring change: Responsiveness of outcome measurements
    • May L: The challenge of measuring change: Responsiveness of outcome measurements. Can J Rehabil 1997;10:15-24
    • (1997) Can J Rehabil , vol.10 , pp. 15-24
    • May, L.1
  • 17
    • 0026867036 scopus 로고
    • Assessment of an infra-red non-contact sensor for routine skin temperature monitoring: A preliminary study
    • Hershler C, Conine TA, Nunn A, et al: Assessment of an infra-red non-contact sensor for routine skin temperature monitoring: A preliminary study. J Med Eng Technol 1992;16:117-22
    • (1992) J Med Eng Technol , vol.16 , pp. 117-122
    • Hershler, C.1    Conine, T.A.2    Nunn, A.3
  • 18
    • 0023693902 scopus 로고
    • Quantification of thermal asymmetry: Part 1. Normal values and reproducibility
    • Uematsu S, Edwin D, Jankel W, et al: Quantification of thermal asymmetry: Part 1. Normal values and reproducibility. J Neurosurg 1988;69:552-5
    • (1988) J Neurosurg , vol.69 , pp. 552-555
    • Uematsu, S.1    Edwin, D.2    Jankel, W.3
  • 19
    • 0030482308 scopus 로고    scopus 로고
    • A comparison of four infrared tympanic thermometers with tympanic membrane temperatures measured by thermocouples
    • Matsukawa T: A comparison of four infrared tympanic thermometers with tympanic membrane temperatures measured by thermocouples. Can J Anaesth 1996;43:1224-8
    • (1996) Can J Anaesth , vol.43 , pp. 1224-1228
    • Matsukawa, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.