메뉴 건너뛰기




Volumn 6142 I, Issue , 2006, Pages

Comparison of three sinogram restoration methods

Author keywords

CT sinogram restoration; Noise; Penalized maximum likelihood; Resolution

Indexed keywords

ANALYTIC DECONVOLUTION; CT SINOGRAM RESTORATION; IMAGE NOISE CONTENT; PENALIZED MAXIMUM LIKELIHOOD; SINOGRAM DECONVOLUTION;

EID: 33745399792     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.652079     Document Type: Conference Paper
Times cited : (5)

References (10)
  • 1
    • 21144458117 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram smoothing for low-dose CT
    • P. J. L. Rivière, "Penalized-likelihood sinogram smoothing for low-dose CT," Med. Phys. 32(6), pp. 1676-1683, 2005.
    • (2005) Med. Phys. , vol.32 , Issue.6 , pp. 1676-1683
    • Rivière, P.J.L.1
  • 5
    • 0034257871 scopus 로고    scopus 로고
    • Investigation of a solid-state detector for advanced computed tomography
    • J. Hsieh, O. E. Gurmen, and K. F. King, "Investigation of a solid-state detector for advanced computed tomography," in IEEE Transactions on Medical Imaging, MI-19, pp. 930-940, 2000.
    • (2000) IEEE Transactions on Medical Imaging , vol.MI-19 , pp. 930-940
    • Hsieh, J.1    Gurmen, O.E.2    King, K.F.3
  • 6
    • 84858897550 scopus 로고
    • "Plural source computerized tomography device with improved resolution". US patent no. 4,637,040
    • A. R. Sohval and D. Freundlich, "Plural source computerized tomography device with improved resolution," 1987. US patent no. 4,637,040.
    • (1987)
    • Sohval, A.R.1    Freundlich, D.2
  • 8
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    • M. Kachelrieß, O. Watzke, and W. A. Kalender, "Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT," Med. Phys. 28(4), pp. 475 - 490, 2001.
    • (2001) Med. Phys. , vol.28 , Issue.4 , pp. 475-490
    • Kachelrieß, M.1    Watzke, O.2    Kalender, W.A.3
  • 9
    • 0031794571 scopus 로고    scopus 로고
    • Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise
    • J. Hsieh, "Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise," Med. Phys. 25(9), pp. 2139 - 2147, 1998.
    • (1998) Med. Phys. , vol.25 , Issue.9 , pp. 2139-2147
    • Hsieh, J.1
  • 10
    • 84858905963 scopus 로고    scopus 로고
    • http://www.imp.uni-erlangen.de/forbild.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.