메뉴 건너뛰기




Volumn 18, Issue 6, 2006, Pages 441-446

The Effect of Belly Board Location in Rectal Cancer Patients Treated with Preoperative Radiotherapy

Author keywords

Belly board; preoperative radiotherapy; rectal cancer; small bowel

Indexed keywords

ADULT; AGED; ARTICLE; BLADDER; CALCULATION; CANCER LOCALIZATION; CLINICAL ARTICLE; CLINICAL PRACTICE; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; HUMAN; LUMBOSACRAL SPINE; MALE; PREOPERATIVE TREATMENT; PRIORITY JOURNAL; PUBIS SYMPHYSIS; RECTUM CANCER; SACROILIAC JOINT; SMALL INTESTINE; TREATMENT PLANNING; WILCOXON SIGNED RANKS TEST;

EID: 33745391372     PISSN: 09366555     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clon.2006.05.001     Document Type: Article
Times cited : (12)

References (17)
  • 1
    • 0036006937 scopus 로고    scopus 로고
    • The dose-volume relationship of acute small bowel toxicity from concurrent 5-FU-based chemotherapy and radiation therapy for rectal cancer
    • Baglan K.L., Frazier R.C., Yan D., Huang R.R., Martinez A.A., and Robertson J.M. The dose-volume relationship of acute small bowel toxicity from concurrent 5-FU-based chemotherapy and radiation therapy for rectal cancer. Int J Radiat Oncol Biol Phys 52 (2002) 176-183
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 176-183
    • Baglan, K.L.1    Frazier, R.C.2    Yan, D.3    Huang, R.R.4    Martinez, A.A.5    Robertson, J.M.6
  • 2
    • 0027967489 scopus 로고
    • The volume effect in radiation-related late small bowel complications: results of a clinical study of the EORTC Radiotherapy Cooperative Group in patients treated for rectal carcinoma
    • Letschert J.G., Lebesque J.V., Aleman B.M., et al. The volume effect in radiation-related late small bowel complications: results of a clinical study of the EORTC Radiotherapy Cooperative Group in patients treated for rectal carcinoma. Radiother Oncol 32 (1994) 116-123
    • (1994) Radiother Oncol , vol.32 , pp. 116-123
    • Letschert, J.G.1    Lebesque, J.V.2    Aleman, B.M.3
  • 3
    • 0027192824 scopus 로고
    • Volumetric analysis of small bowel displacement from radiation portals with the use of a pelvic tissue expander
    • Herbert S.H., Solin L.J., Hoffman J.P., et al. Volumetric analysis of small bowel displacement from radiation portals with the use of a pelvic tissue expander. Int J Radiat Oncol Biol Phys 25 (1993) 885-893
    • (1993) Int J Radiat Oncol Biol Phys , vol.25 , pp. 885-893
    • Herbert, S.H.1    Solin, L.J.2    Hoffman, J.P.3
  • 4
    • 0032006213 scopus 로고    scopus 로고
    • Effect of customized small bowel displacement system in pelvic irradiation
    • Huh S.J., Lim D.H., Ahn Y.C., et al. Effect of customized small bowel displacement system in pelvic irradiation. Int J Radiat Oncol Biol Phys 40 (1998) 623-627
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 623-627
    • Huh, S.J.1    Lim, D.H.2    Ahn, Y.C.3
  • 5
    • 0023000608 scopus 로고
    • A prospective study of treatment techniques to minimize the volume of pelvic small bowel with reduction of acute and late effects associated with pelvic irradiation
    • Gallagher M.J., Brereton H.D., Rostock R.A., et al. A prospective study of treatment techniques to minimize the volume of pelvic small bowel with reduction of acute and late effects associated with pelvic irradiation. Int J Radiat Oncol Biol Phys 12 (1986) 1565-1573
    • (1986) Int J Radiat Oncol Biol Phys , vol.12 , pp. 1565-1573
    • Gallagher, M.J.1    Brereton, H.D.2    Rostock, R.A.3
  • 7
    • 0030826232 scopus 로고    scopus 로고
    • Efficacy of a belly board device with CT-simulation in reducing small bowel volume within pelvic irradiation fields
    • Das I.J., Lanciano R.M., Movsas B., Kagawa K., and Barnes S.J. Efficacy of a belly board device with CT-simulation in reducing small bowel volume within pelvic irradiation fields. Int J Radiat Oncol Biol Phys 39 (1997) 67-76
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , pp. 67-76
    • Das, I.J.1    Lanciano, R.M.2    Movsas, B.3    Kagawa, K.4    Barnes, S.J.5
  • 8
    • 0035479040 scopus 로고    scopus 로고
    • Dislocation of small bowel volume within box pelvic treatment fields, using new "up down table" device
    • Capirci C., Polico C., and Mandoliti G. Dislocation of small bowel volume within box pelvic treatment fields, using new "up down table" device. Int J Radiat Oncol Biol Phys 51 (2001) 465-473
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 465-473
    • Capirci, C.1    Polico, C.2    Mandoliti, G.3
  • 9
    • 0032793389 scopus 로고    scopus 로고
    • Influence of patient positioning on dose-volume histogram and normal tissue complication probability for small bowel and bladder in patients receiving pelvic irradiation: a prospective study using a 3D planning system and a radiobiological model
    • Koelbl O., Richter S., and Flentje M. Influence of patient positioning on dose-volume histogram and normal tissue complication probability for small bowel and bladder in patients receiving pelvic irradiation: a prospective study using a 3D planning system and a radiobiological model. Int J Radiat Oncol Biol Phys 45 (1999) 1193-1198
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 1193-1198
    • Koelbl, O.1    Richter, S.2    Flentje, M.3
  • 10
    • 0025088593 scopus 로고
    • Minimization of small bowel volume within treatment fields utilizing customized "belly boards"
    • Shanahan T.G., Mehta M.P., Bertelrud K.L., et al. Minimization of small bowel volume within treatment fields utilizing customized "belly boards". Int J Radiat Oncol Biol Phys 19 (1990) 469-476
    • (1990) Int J Radiat Oncol Biol Phys , vol.19 , pp. 469-476
    • Shanahan, T.G.1    Mehta, M.P.2    Bertelrud, K.L.3
  • 11
    • 20344400357 scopus 로고    scopus 로고
    • Comparison of the belly board device method and the distended bladder method for reducing irradiated small bowel volumes in preoperative radiotherapy of rectal cancer patients
    • Kim T.H., Chie E.K., Kim D.Y., et al. Comparison of the belly board device method and the distended bladder method for reducing irradiated small bowel volumes in preoperative radiotherapy of rectal cancer patients. Int J Radiat Oncol Biol Phys 62 (2005) 769-775
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 769-775
    • Kim, T.H.1    Chie, E.K.2    Kim, D.Y.3
  • 12
    • 0029118975 scopus 로고
    • Measurement of irradiated small bowel volume in pelvic irradiation and the effect of a bellyboard
    • Fu Y.T., Lam J.C., and Tze J.M. Measurement of irradiated small bowel volume in pelvic irradiation and the effect of a bellyboard. Clin Oncol (R Coll Radiol) 7 (1995) 188-192
    • (1995) Clin Oncol (R Coll Radiol) , vol.7 , pp. 188-192
    • Fu, Y.T.1    Lam, J.C.2    Tze, J.M.3
  • 13
    • 0035313822 scopus 로고    scopus 로고
    • Reduction of irradiated small bowel volume and accurate patient positioning by use of a bellyboard device in pelvic radiotherapy of gynecological cancer patients
    • Olofsen-van Acht M., van den Berg H., Quint S., et al. Reduction of irradiated small bowel volume and accurate patient positioning by use of a bellyboard device in pelvic radiotherapy of gynecological cancer patients. Radiother Oncol 59 (2001) 87-93
    • (2001) Radiother Oncol , vol.59 , pp. 87-93
    • Olofsen-van Acht, M.1    van den Berg, H.2    Quint, S.3
  • 14
    • 0034765040 scopus 로고    scopus 로고
    • Using a belly board device to reduce the small bowel volume within pelvic radiation fields in women with postoperatively treated cervical carcinoma
    • Ghosh K., Padilla L.A., Murray K.P., Downs L.S., Carson L.F., and Dusenbery K.E. Using a belly board device to reduce the small bowel volume within pelvic radiation fields in women with postoperatively treated cervical carcinoma. Gynecol Oncol 83 (2001) 271-275
    • (2001) Gynecol Oncol , vol.83 , pp. 271-275
    • Ghosh, K.1    Padilla, L.A.2    Murray, K.P.3    Downs, L.S.4    Carson, L.F.5    Dusenbery, K.E.6
  • 15
    • 0036603603 scopus 로고    scopus 로고
    • The variability of the clinical target volume for rectal cancer due to internal organ motion during adjuvant treatment
    • Nuyttens J.J., Robertson J.M., Yan D., et al. The variability of the clinical target volume for rectal cancer due to internal organ motion during adjuvant treatment. Int J Radiat Oncol Biol Phys 53 (2002) 497-503
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 497-503
    • Nuyttens, J.J.1    Robertson, J.M.2    Yan, D.3
  • 16
    • 0028361166 scopus 로고
    • The variation of small bowel volume within the pelvis before and during adjuvant radiation for rectal cancer
    • Brierley J.D., Cummings B.J., Wong C.S., McLean M., Cashell A., and Manter S. The variation of small bowel volume within the pelvis before and during adjuvant radiation for rectal cancer. Radiother Oncol 31 (1994) 110-116
    • (1994) Radiother Oncol , vol.31 , pp. 110-116
    • Brierley, J.D.1    Cummings, B.J.2    Wong, C.S.3    McLean, M.4    Cashell, A.5    Manter, S.6
  • 17
    • 0038642531 scopus 로고    scopus 로고
    • The relationship between belly board position and patient anatomy and its influence on dose-volume histogram of small bowel for postoperative radiotherapy of rectal cancer
    • Koelbl O., Vordermark D., and Flentje M. The relationship between belly board position and patient anatomy and its influence on dose-volume histogram of small bowel for postoperative radiotherapy of rectal cancer. Radiother Oncol 67 (2003) 345-349
    • (2003) Radiother Oncol , vol.67 , pp. 345-349
    • Koelbl, O.1    Vordermark, D.2    Flentje, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.