메뉴 건너뛰기




Volumn 6143 I, Issue , 2006, Pages

Reproducibility of brain hemodynamic simulations: An inter-solver comparison

Author keywords

Hemodynamics; Patient specific; Simulation

Indexed keywords

CURVATURE FLOW; HEMODYNAMIC SIMULATIONS; IMAGING-BASED SIMULATIONS; PATIENT-SPECIFIC;

EID: 33745386310     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.653970     Document Type: Conference Paper
Times cited : (5)

References (27)
  • 1
    • 0642311549 scopus 로고    scopus 로고
    • Blood flow in arteries
    • D. N. Ku, "Blood Flow in Arteries", Annu. Rev. Fluid Mech., 1997. 29:399-434
    • (1997) Annu. Rev. Fluid Mech. , vol.29 , pp. 399-434
    • Ku, D.N.1
  • 3
    • 0343194020 scopus 로고
    • Platelet aggregate formation in a region of separated blood flow
    • E. M. Parmentier, W. A. Morton, and H. E. Petschek "Platelet aggregate formation in a region of separated blood flow" Physics of Fluids 1977; 20: pp. 2012-2021
    • (1977) Physics of Fluids , vol.20 , pp. 2012-2021
    • Parmentier, E.M.1    Morton, W.A.2    Petschek, H.E.3
  • 4
    • 0021966255 scopus 로고
    • Pulsatile flow and atherosclerosis in the human carotid bifurcation - Positive correlation between plaque location and low and oscillating shear-stress
    • D. N. Ku, D. P. Giddens, C. K. Zarins, et al., "Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation - Positive Correlation Between Plaque Location and Low and Oscillating Shear-Stress", Arteriosclerosis 5 (3): 293-302 1985
    • (1985) Arteriosclerosis , vol.5 , Issue.3 , pp. 293-302
    • Ku, D.N.1    Giddens, D.P.2    Zarins, C.K.3
  • 6
    • 2442677833 scopus 로고    scopus 로고
    • Intraaneurysmal flow visualization by using phase-contrast magnetic resonance imaging: Feasibility study based on a geometrically realistic in vitro aneurysm model
    • S. Tateshima, J. Grinstead, S. Sinha, et al., "Intraaneurysmal flow visualization by using phase-contrast magnetic resonance imaging: feasibility study based on a geometrically realistic in vitro aneurysm model" JournalL of Neurosurgery 100 (6): 1041-10482004
    • (2004) JournalL of Neurosurgery , vol.100 , Issue.6 , pp. 1041-1048
    • Tateshima, S.1    Grinstead, J.2    Sinha, S.3
  • 7
    • 0041419596 scopus 로고    scopus 로고
    • Three-dimensional blood flow analysis in a wide-necked internal carotid artery-ophthalmic artery aneurysm
    • S. Tateshima, F. Vinuela, J. P. Villablanca, et al., "Three- dimensional blood flow analysis in a wide-necked internal carotid artery-ophthalmic artery aneurysm" JournalL of Neurosurgery 99 (3): 526-533 2003
    • (2003) JournalL of Neurosurgery , vol.99 , Issue.3 , pp. 526-533
    • Tateshima, S.1    Vinuela, F.2    Villablanca, J.P.3
  • 8
    • 0031848130 scopus 로고    scopus 로고
    • Hemodynamics of human carotid artery bifurcations: Computational studies with models reconstructed from magnetic resonance imaging of normal subjects
    • JUL
    • J. S. Milner, J. A. Moore, B. K. Rutt, D. A. Steinman, "Hemodynamics of human carotid artery bifurcations: Computational studies with models reconstructed from magnetic resonance imaging of normal subjects", Journal of Vascular Surgery 28 (1): 143-156 JUL 1998
    • (1998) Journal of Vascular Surgery , vol.28 , Issue.1 , pp. 143-156
    • Milner, J.S.1    Moore, J.A.2    Rutt, B.K.3    Steinman, D.A.4
  • 9
    • 0142072546 scopus 로고    scopus 로고
    • Computational approach to quantifying hernodynamic: Forces in giant cerebral aneurysms
    • L. D. Jou, C. M. Quick, VV. L. Young, et al., "Computational approach to quantifying hernodynamic: forces in giant cerebral aneurysms" American Journal of Neuroradiology 24 (9):1804-1810 2003
    • (2003) American Journal of Neuroradiology , vol.24 , Issue.9 , pp. 1804-1810
    • Jou, L.D.1    Quick, C.M.2    Young, V.V.L.3
  • 10
    • 17444424630 scopus 로고    scopus 로고
    • Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity
    • J. R. Cebral, M. A. Castro, S. Appanaboyina, et al., "Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity" IEEE Transactions on Medical Imaging 24 (4): 457-467 2005
    • (2005) IEEE Transactions on Medical Imaging , vol.24 , Issue.4 , pp. 457-467
    • Cebral, J.R.1    Castro, M.A.2    Appanaboyina, S.3
  • 11
    • 0037224366 scopus 로고    scopus 로고
    • Reproducibility of image-based computational fluid dynamics models of the human carotid bifurcation
    • J. B. Thomas, J. S. Milner, B. K. Rutt, and D. A. Steinman, "Reproducibility of Image-Based Computational Fluid Dynamics Models of the Human Carotid Bifurcation". Annals of Biomedical Engineering, Vol. 31, 2003, pp. 132-141
    • (2003) Annals of Biomedical Engineering , vol.31 , pp. 132-141
    • Thomas, J.B.1    Milner, J.S.2    Rutt, B.K.3    Steinman, D.A.4
  • 12
    • 0037224387 scopus 로고    scopus 로고
    • Reproducibility study of magnetic resonance image-based computational fluid dynamics prediction of carotid bifurcation flow
    • F. P. Glor, Q. Long, A. D. Hughes, A. D. August, et al., "Reproducibility Study of Magnetic Resonance Image-Based Computational Fluid Dynamics Prediction of Carotid Bifurcation Flow", Annals of Biomedical Engineering, Vol. 31, 2003, pp. 142-15
    • (2003) Annals of Biomedical Engineering , vol.31 , pp. 142-215
    • Glor, F.P.1    Long, Q.2    Hughes, A.D.3    August, A.D.4
  • 13
    • 17444377231 scopus 로고    scopus 로고
    • Comparison of CFD and MRI flow and velocity in an in Vitro large artery bypass graft model
    • March
    • J. P. Ku, C. J. Elkins, and C. A. Taylor, "Comparison of CFD and MRI Flow and Velocity in an In Vitro Large Artery Bypass Graft Model" Annals of Biomedical Engineering, Vol. 33, No. 3, March 2005, pp. 257-269
    • (2005) Annals of Biomedical Engineering , vol.33 , Issue.3 , pp. 257-269
    • Ku, J.P.1    Elkins, C.J.2    Taylor, C.A.3
  • 15
    • 23844501404 scopus 로고    scopus 로고
    • Correlating aneurysm growth to hemodynamic parameters: The case of a patient-specific anterior communicating artery aneurysm
    • ISSN 1605-7422 780-791
    • P. Venugopal, H. Chen, G. Duckwiler, R. Kemkers, et al., "Correlating aneurysm growth to hemodynamic parameters: the case of a patient-specific anterior communicating artery aneurysm" Progress in Biomedical Optics and Imaging Vol. 6, No 23, ISSN 1605-7422 780-791, 2005
    • (2005) Progress in Biomedical Optics and Imaging , vol.6 , Issue.23
    • Venugopal, P.1    Chen, H.2    Duckwiler, G.3    Kemkers, R.4
  • 16
    • 84858898708 scopus 로고    scopus 로고
    • http://www.fluent.com/, 2005
    • (2005)
  • 17
    • 84858890095 scopus 로고    scopus 로고
    • http://www.openfoam.com/, 2005
    • (2005)
  • 18
    • 0000474617 scopus 로고    scopus 로고
    • A tensorial approach to CFD using object orientated techniques
    • H. G. Weller, G. Tabor, H. Jasak, and C. Fureby, "A Tensorial Approach to CFD using Object Orientated Techniques", Computers in Physics, 1998 v 12 n 6, pp 620-631
    • (1998) Computers in Physics , vol.12 , Issue.6 , pp. 620-631
    • Weller, H.G.1    Tabor, G.2    Jasak, H.3    Fureby, C.4
  • 19
    • 85086492766 scopus 로고    scopus 로고
    • Improving the speed and accuracy of projection-type incompressible flow solvers
    • Reno, Nevada,January
    • R. Lohner, C. Yang, J.R. Cebral, O. Soto, F. Camelli, and J. Waltz. "Improving the speed and accuracy of projection-type incompressible flow solvers", AIAA Aerospace Science Meeting. 2003,Vol.AIAA-03-3391, Reno, Nevada,January.
    • (2003) AIAA Aerospace Science Meeting , vol.AIAA-03-3391
    • Lohner, R.1    Yang, C.2    Cebral, J.R.3    Soto, O.4    Camelli, F.5    Waltz, J.6
  • 22
    • 0032209239 scopus 로고    scopus 로고
    • A fast matrix-free implicit method for compressible flows on unstructured grids
    • H. Luo, J.D. Baum, and R. Lohner, "A fast matrix-free implicit method for compressible flows on unstructured grids", Journal of Computational Physics, 1998, 146: 664-690.
    • (1998) Journal of Computational Physics , vol.146 , pp. 664-690
    • Luo, H.1    Baum, J.D.2    Lohner, R.3
  • 23
    • 84894361957 scopus 로고    scopus 로고
    • Implementation of unstructured grid GM-RES+LUSGS method on shared-memory, cache-based parallel computers
    • Reno, Nevada
    • D. Sharov, H. Luo, J.D. Baum, and R. Lohner, "Implementation of unstructured grid GM-RES+LUSGS method on shared-memory, cache-based parallel computers", AIAA Aerospace Science Meeting, 2000,Vol.AIAA-00-0927, Reno, Nevada.
    • (2000) AIAA Aerospace Science Meeting , vol.AIAA-00-0927
    • Sharov, D.1    Luo, H.2    Baum, J.D.3    Lohner, R.4
  • 24
    • 0017768368 scopus 로고
    • Laminar flow in a square duct of strong curvature
    • J. A. C. Humphrey, A. M. K. Taylor and J. H. Whitelaw, "Laminar flow in a square duct of strong curvature", J. Fluid Mech. vol. 83, part 3, pp. 509-527 1977.
    • (1977) J. Fluid Mech. , vol.83 , Issue.3 PART , pp. 509-527
    • Humphrey, J.A.C.1    Taylor, A.M.K.2    Whitelaw, J.H.3
  • 25
    • 84858898704 scopus 로고    scopus 로고
    • http://www.amiravis.com/, 2005
    • (2005)
  • 26
    • 0023091554 scopus 로고    scopus 로고
    • A bifurcation study of laminar flow in a curved tube of rectangular cross-section
    • K. Winters, "A Bifurcation Study of Laminar Flow in a Curved Tube of Rectangular Cross-Section" J. Fluid Mech. vol. 180, pp 343-369
    • J. Fluid Mech. , vol.180 , pp. 343-369
    • Winters, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.