Real time; Right ventricular volume; Right ventricular wall mass; Three dimensional echocardiography
Indexed keywords
LATEX;
SILICON;
ACCURACY;
ANIMAL TISSUE;
ARTICLE;
CONTROLLED STUDY;
FEASIBILITY STUDY;
HEART RIGHT VENTRICLE VOLUME;
HEART VENTRICLE WALL;
IN VITRO STUDY;
MASS;
MEASUREMENT;
NONHUMAN;
PRIORITY JOURNAL;
REAL TIME ECHOCARDIOGRAPHY;
REAL TIME ECHOGRAPHY;
THREE DIMENSIONAL ECHOCARDIOGRAPHY;
VALIDATION PROCESS;
ANALYSIS OF VARIANCE;
ANIMALS;
COMPUTER SYSTEMS;
ECHOCARDIOGRAPHY, THREE-DIMENSIONAL;
EQUIPMENT DESIGN;
FEASIBILITY STUDIES;
HYPERTROPHY, RIGHT VENTRICULAR;
IMAGE PROCESSING, COMPUTER-ASSISTED;
OBSERVER VARIATION;
REPRODUCIBILITY OF RESULTS;
SENSITIVITY AND SPECIFICITY;
SWINE;
VENTRICULAR FUNCTION, RIGHT;
Length method in evaluating right ventricular volume in children with congenital heart disease: A comparison with two dimensional echocardiographic method
Sun K, Chen SB, Bian RX, et al : Length method in evaluating right ventricular volume in children with congenital heart disease: A comparison with two dimensional echocardiographic method. Zhonghua Yi Xue Za Zhi 1993 73 : 535 537, 574 575.
Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass
Vogel M, Gutberlet M, Dittrich S, et al : Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass. Heart 1997 78 : 127 130.
Three-dimensional echocardiographic measurement of right ventricular volume in children with congenital heart disease validated by magnetic resonance imaging
Papavassiliou DP, Parks WJ, Hopkins KL, et al : Three-dimensional echocardiographic measurement of right ventricular volume in children with congenital heart disease validated by magnetic resonance imaging. J Am Soc Echocardiogr 1998 11 : 770 777.
Real-time three-dimensional echocardiography: Feasibility of dynamic right ventricular volume measurement with saline contrast
Ota T, Fleishman CE, Strub M, et al : Real-time three-dimensional echocardiography: Feasibility of dynamic right ventricular volume measurement with saline contrast. Am Heart J 1999 137 : 958 966.
Accuracy of real-time three-dimensional echocardiography for quantifying right ventricular volume: Static and pulsatile flow studies in an anatomic in vitro model
Schindera ST, Mehwald PS, Sahn DJ, et al : Accuracy of real-time three-dimensional echocardiography for quantifying right ventricular volume: Static and pulsatile flow studies in an anatomic in vitro model. J Ultrasound Med 2002 21 : 1069 1075.
High-resolution transthoracic real-time three-dimensional echocardiography: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging
Kuhl HP, Schreckenberg M, Rulands D, et al : High-resolution transthoracic real-time three-dimensional echocardiography: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging. J Am Coll Cardiol 2004 43 : 2083 2090.