메뉴 건너뛰기




Volumn 6142 III, Issue , 2006, Pages

Scatter correction for kilovoltage cone-beam computed tomography (CBCT) images using Monte Carlo simulations

Author keywords

Cone Beam CT; Image quality; Monte Carlo simulation; Scatter correction

Indexed keywords

COMPUTER SIMULATION; IMAGE QUALITY; IMAGE RECONSTRUCTION; MEDICAL IMAGING; MONTE CARLO METHODS; X RAY TUBES;

EID: 33745363451     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.653803     Document Type: Conference Paper
Times cited : (13)

References (14)
  • 1
    • 0035110308 scopus 로고    scopus 로고
    • Cone-Beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
    • J. H. Siewerdsen and D. A. Jaffray, "Cone-Beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter," Med. Phys. 28 220-231 (2000)
    • (2000) Med. Phys. , vol.28 , pp. 220-231
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 2
    • 0033849841 scopus 로고    scopus 로고
    • Optimization of x-ray imaging geometry with specific application to flat panel cone-beam computed tomography
    • J. H. Siewerdsen and D. A. Jaffray, "Optimization of x-ray imaging geometry (with specific application to flat panel cone-beam computed tomography," Med. Phys. 27 1903-1914 (2000)
    • (2000) Med. Phys. , vol.27 , pp. 1903-1914
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 3
    • 2442689175 scopus 로고    scopus 로고
    • X-ray scatter correction algorithm for cone beam CT imaging
    • R. Ning, X. Tang, and D. Conover, "X-ray scatter correction algorithm for cone beam CT imaging," Med. Phys. 31 1195-1202 (2004)
    • (2004) Med. Phys. , vol.31 , pp. 1195-1202
    • Ning, R.1    Tang, X.2    Conover, D.3
  • 5
    • 31044451240 scopus 로고    scopus 로고
    • A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone beam CT
    • J. H. Siewerdsen, M. J. Daly, B. Bakhtiar, D. J. Moseley, S. Richard, H. Keller, D. A. Jaffray, "A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone beam CT," Med. Phys. 33 187-197 (2006)
    • (2006) Med. Phys. , vol.33 , pp. 187-197
    • Siewerdsen, J.H.1    Daly, M.J.2    Bakhtiar, B.3    Moseley, D.J.4    Richard, S.5    Keller, H.6    Jaffray, D.A.7
  • 6
    • 31044435647 scopus 로고    scopus 로고
    • A scanning sampled measurement (SSM) technique for scatter measurement and correction in cone beam breast CT
    • Abstract
    • X. Liu, C. Shaw, M. Altunbas, T. Wang, "A scanning sampled measurement (SSM) technique for scatter measurement and correction in cone beam breast CT," Med. Phys. 32 2093 (Abstract) (2005)
    • (2005) Med. Phys. , vol.32 , pp. 2093
    • Liu, X.1    Shaw, C.2    Altunbas, M.3    Wang, T.4
  • 7
    • 0019362320 scopus 로고
    • Monte Carlo calculations of x-ray scatter data for diagnostic radiology
    • W. Kalender, "Monte Carlo calculations of x-ray scatter data for diagnostic radiology," Phys. Med. Biol. 26, 835-849 (1981)
    • (1981) Phys. Med. Biol. , vol.26 , pp. 835-849
    • Kalender, W.1
  • 8
    • 0021906794 scopus 로고
    • Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies
    • H.-P. Chan and K. Doi, "Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies," Med. Phys. 12, 152-165 (1984)
    • (1984) Med. Phys. , vol.12 , pp. 152-165
    • Chan, H.-P.1    Doi, K.2
  • 9
    • 0023736317 scopus 로고
    • Monte Carlo simulation of the scattered radiation distribution in diagnostic radiology
    • J. M. Boone and J. A. Seibert, "Monte Carlo simulation of the scattered radiation distribution in diagnostic radiology," Med. Phys. 15, 713-720 (1988)
    • (1988) Med. Phys. , vol.15 , pp. 713-720
    • Boone, J.M.1    Seibert, J.A.2
  • 10
    • 0041374297 scopus 로고    scopus 로고
    • Simulation of scatter in cone beam CT- Effect on projection image quality
    • A. Malusek, M. Sandborg, and G. A. Carlsson, "Simulation of scatter in cone beam CT- effect on projection image quality," Proc. SPIE 5030, 740-751 (2003)
    • (2003) Proc. SPIE , vol.5030 , pp. 740-751
    • Malusek, A.1    Sandborg, M.2    Carlsson, G.A.3
  • 11
    • 26244447829 scopus 로고    scopus 로고
    • Development and validation of MCNP4C-based Monte Carlo simulator for fan- And conebeam x-ray CT
    • M.Reza Ay and H. Zaidi, "development and validation of MCNP4C-based Monte Carlo simulator for fan- and conebeam x-ray CT," Phys. Med. Biol. 50 4863-4885 (2005)
    • (2005) Phys. Med. Biol. , vol.50 , pp. 4863-4885
    • Ay, M.R.1    Zaidi, H.2
  • 12
    • 33745414296 scopus 로고    scopus 로고
    • Characterization of scatter radiation in kV CBCT images using Monte Carlo simulations
    • submitted to
    • G. Jarry, S. Graham, D. Moseley, D. Jaffray, and F. Verhaegen, "Characterization of scatter radiation in kV CBCT images using Monte Carlo simulations," submitted to Med. Phys. (2006)
    • (2006) Med. Phys.
    • Jarry, G.1    Graham, S.2    Moseley, D.3    Jaffray, D.4    Verhaegen, F.5
  • 14
    • 0038644818 scopus 로고    scopus 로고
    • DOSXYZnrc users manual
    • Ottawa, Canada: NRCC
    • B. Walters, I. Kawrakow and D. W. O. Rogers, "DOSXYZnrc users manual," NRCC Report PIRS-794revB (Ottawa, Canada: NRCC) (2004)
    • (2004) NRCC Report , vol.PIRS-794REVB
    • Walters, B.1    Kawrakow, I.2    Rogers, D.W.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.