메뉴 건너뛰기




Volumn 6142 III, Issue , 2006, Pages

Penalized weighted least-squares approach for low-dose X-ray computed tomography

Author keywords

KL transform; Low dose CT; Noise resolution tradeoff; Penalized weighted least squares (PWLS); ROC curve

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; IMAGE PROCESSING; IMAGE RECONSTRUCTION; ITERATIVE METHODS; LEAST SQUARES APPROXIMATIONS; NONLINEAR SYSTEMS; STATISTICAL METHODS; X RAYS;

EID: 33745357597     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.653903     Document Type: Conference Paper
Times cited : (4)

References (27)
  • 1
    • 0042845953 scopus 로고    scopus 로고
    • National conference on dose reduction in CT, with an emphasis on pediatric patients
    • Linton O.W., Fred A., and Mettler F.A., "National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients", American Journal of Roentgenology Vol. 181, pp. 321-329, 2003.
    • (2003) American Journal of Roentgenology , vol.181 , pp. 321-329
    • Linton, O.W.1    Fred, A.2    Mettler, F.A.3
  • 2
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lange K. and Carson R., "EM Reconstruction Algorithms for Emission and Transmission Tomography", J. Computer Assisted Tomography, Vol. 8, pp. 306-316, 1984.
    • (1984) J. Computer Assisted Tomography , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 3
    • 0042421775 scopus 로고    scopus 로고
    • Efficient and accurate likelihood for iterative image reconstruction in X-ray computed tomography
    • Elbakri I.A. and Fessler J.A., "Efficient and Accurate Likelihood for Iterative Image Reconstruction in X-ray Computed Tomography", Proc. SPIE Med. Imaging, Vol. 5032, pp. 1839-1850, 2003.
    • (2003) Proc. SPIE Med. Imaging , vol.5032 , pp. 1839-1850
    • Elbakri, I.A.1    Fessler, J.A.2
  • 4
    • 0036033694 scopus 로고    scopus 로고
    • Analytical noise treatment for low-dose CT projection data by penalized weighted least-square smoothing in the K-L domain
    • Lu H., Li X., Hsiao I.T., and Liang Z., "Analytical Noise Treatment for Low-Dose CT Projection Data by Penalized Weighted Least-Square Smoothing in the K-L Domain", Proc. SPIE Med Imaging, Vol. 4682, pp. 146-152, 2002.
    • (2002) Proc. SPIE Med Imaging , vol.4682 , pp. 146-152
    • Lu, H.1    Li, X.2    Hsiao, I.T.3    Liang, Z.4
  • 6
    • 11844305985 scopus 로고    scopus 로고
    • Reduction of noise-induced streak artifacts in X-ray computed tomography through spline-based penalized-likelihood sinogram smoothing
    • La Rivière P.J. and Billmire D.M., "Reduction of Noise-Induced Streak Artifacts in X-ray Computed Tomography Through Spline-Based Penalized-Likelihood Sinogram Smoothing", IEEE. Trans. Med. Imaging, Vol. 24, pp. 105-111, 2005.
    • (2005) IEEE. Trans. Med. Imaging , vol.24 , pp. 105-111
    • La Rivière, P.J.1    Billmire, D.M.2
  • 7
    • 21144458117 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram smoothing for low-dose CT
    • La Riviëre P.J.: Penalized-Likelihood Sinogram Smoothing for Low-Dose CT, Medical Physics, Vol. 32, pp. 1676-1683, 2005.
    • (2005) Medical Physics , vol.32 , pp. 1676-1683
    • La Riviëre, P.J.1
  • 8
    • 0026222041 scopus 로고
    • Non-stationary filtering of transmission tomograms in high photon counting noise
    • Sauer K. and Liu B., "Non-Stationary Filtering of Transmission Tomograms in High Photon Counting Noise", IEEE Trans. Med. Imaging, Vol. 10, pp. 445-452, 1991.
    • (1991) IEEE Trans. Med. Imaging , vol.10 , pp. 445-452
    • Sauer, K.1    Liu, B.2
  • 9
    • 0031794571 scopus 로고    scopus 로고
    • Adaptive streak artifact reduction in computed tomography resulting from excessive X-ray photon noise
    • Hsieh J., "Adaptive Streak Artifact Reduction in Computed Tomography Resulting from Excessive X-ray Photon Noise", Medical Physics, Vol. 25, pp. 2139-2147, 1998.
    • (1998) Medical Physics, Vol. , vol.25 , pp. 2139-2147
    • Hsieh, J.1
  • 10
    • 0034839479 scopus 로고    scopus 로고
    • Reduction of noise and image artifacts in computed tomography by nonlinear filtration of the projection images
    • Demirkaya K., "Reduction of Noise and Image Artifacts in Computed Tomography by Nonlinear Filtration of the Projection Images", Proc. SPIE Med. Imaging, Vol. 4322, pp. 917-923, 2001.
    • (2001) Proc. SPIE Med. Imaging , vol.4322 , pp. 917-923
    • Demirkaya, K.1
  • 11
    • 2942517963 scopus 로고    scopus 로고
    • Image denoising based on multiscale singularity detection for cone beam CT breast imaging
    • Zhong J., Ning R., and Conover D., "Image Denoising Based on Multiscale Singularity Detection for Cone Beam CT Breast Imaging", IEEE Trans. Med. Imaging, Vol. 23, pp. 696-703, 2004.
    • (2004) IEEE Trans. Med. Imaging , vol.23 , pp. 696-703
    • Zhong, J.1    Ning, R.2    Conover, D.3
  • 12
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    • Kachelrieß M., Watzke O., and Kalender W.A., "Generalized Multi-Dimensional Adaptive Filtering for Conventional and Spiral Single-Slice, Multi-Slice, and Cone-Beam CT", Medical Physics, Vol. 28, pp. 475-490, 2001.
    • (2001) Medical Physics , vol.28 , pp. 475-490
    • Kachelrieß, M.1    Watzke, O.2    Kalender, W.A.3
  • 13
    • 0036032163 scopus 로고    scopus 로고
    • Noise/dose reduction and image improvements in screening virtual colonoscopy with tube currents of 20 mAs with nonlinear gaussian filter chains
    • Rust G.F., Aurich V., and Reiser M., "Noise/Dose Reduction and Image Improvements in Screening Virtual Colonoscopy with Tube Currents of 20 mAs with Nonlinear Gaussian Filter Chains", Proc. SPIE Med. Imaging, Vol. 4683, pp. 186-197, 2002.
    • (2002) Proc. SPIE Med. Imaging , vol.4683 , pp. 186-197
    • Rust, G.F.1    Aurich, V.2    Reiser, M.3
  • 15
    • 0035554667 scopus 로고    scopus 로고
    • Noise properties of low-dose CT projections and noise treatment by scale transformations
    • in CD-ROM
    • Lu H., Hsiao I., Li X., and Liang, Z., "Noise Properties of Low-Dose CT Projections and Noise Treatment by Scale Transformations", Conf Record IEEE NSS-MIC, in CD-ROM, 2001.
    • (2001) Conf Record IEEE NSS-MIC
    • Lu, H.1    Hsiao, I.2    Li, X.3    Liang, Z.4
  • 16
    • 23844506912 scopus 로고    scopus 로고
    • Sinogram noise reduction for low-dose CT by statistics-based nonlinear filters
    • Wang J., Lu H., Li T., and Liang, Z., "Sinogram Noise Reduction for Low-Dose CT by Statistics-Based Nonlinear Filters", Proc. SPIE Med. Imaging, Vol. 5747, pp. 2058-2066, 2005.
    • (2005) Proc. SPIE Med. Imaging , vol.5747 , pp. 2058-2066
    • Wang, J.1    Lu, H.2    Li, T.3    Liang, Z.4
  • 17
    • 0027542459 scopus 로고
    • A local update strategy for iterative reconstruction form projections
    • Sauer K. and Bouman C., "A Local Update Strategy for Iterative Reconstruction form Projections", IEEE Trans. Signal Processing, Vol. 41, pp. 534-548, 1993.
    • (1993) IEEE Trans. Signal Processing , vol.41 , pp. 534-548
    • Sauer, K.1    Bouman, C.2
  • 19
    • 0023422273 scopus 로고
    • Noise and edge artifacts in maximum-likelihood reconstruction for emission tomography
    • Snyder D., Miller M., Thomas L., and Politte D., "Noise and Edge Artifacts in Maximum-Likelihood Reconstruction for Emission Tomography", IEEE Trans. Med. Imaging, Vol. 6, pp. 228-238, 1987.
    • (1987) IEEE Trans. Med. Imaging , vol.6 , pp. 228-238
    • Snyder, D.1    Miller, M.2    Thomas, L.3    Politte, D.4
  • 20
    • 0028446166 scopus 로고
    • Penalized weighted least-squares image reconstruction for positron emission tomography
    • Fessler J.A., "Penalized Weighted Least-Squares Image Reconstruction for Positron Emission Tomography", IEEE Trans. Med. Imaging, Vol. 13, pp. 290-300, 1994.
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 290-300
    • Fessler, J.A.1
  • 21
    • 0034310513 scopus 로고    scopus 로고
    • Penalized weighted least-squares image reconstruction for dual energy X-ray computed tomography
    • Sukovic P. and Clinthorne N.H., "Penalized Weighted Least-Squares Image Reconstruction for Dual energy X-ray Computed Tomography", IEEE Trans. Med. Imaging., Vol. 19, pp. 1075-1081, 2000.
    • (2000) IEEE Trans. Med. Imaging. , vol.19 , pp. 1075-1081
    • Sukovic, P.1    Clinthorne, N.H.2
  • 22
  • 24
    • 0022470978 scopus 로고
    • ROC methodology in radiological imaging
    • Metz C.E., "ROC Methodology in Radiological Imaging", Invest. Radiology, Vol. 21, pp. 720-733, 1986.
    • (1986) Invest. Radiology , vol.21 , pp. 720-733
    • Metz, C.E.1
  • 25
    • 0023502720 scopus 로고
    • Addition of a channel mechanism to the ideal-observer model
    • Myers K.J. and Barrett H.H., "Addition of a Channel Mechanism to the Ideal-Observer Model", J. Opt. Soc. America, Vol. 4, pp. 447-57, 1987.
    • (1987) J. Opt. Soc. America , vol.4 , pp. 447-457
    • Myers, K.J.1    Barrett, H.H.2
  • 26
    • 24444461065 scopus 로고    scopus 로고
    • Comparison of human and channelized hotelling observers in myocardial defect detection in SPECT
    • Wollenweber S.D., Tsui B.M.W., Frey E.C., Lalush D.S., and LaCroix K.J., "Comparison of Human and Channelized Hotelling Observers in Myocardial Defect Detection in SPECT", J. Nucl, Med., Vol. 39, p. 771A, 1998.
    • (1998) J. Nucl, Med. , vol.39
    • Wollenweber, S.D.1    Tsui, B.M.W.2    Frey, E.C.3    Lalush, D.S.4    Lacroix, K.J.5
  • 27
    • 0032141943 scopus 로고    scopus 로고
    • Evaluation of myocardial defect detection between parallel-hole and fan beam SPECT using hotelling trace
    • Wollenweber S.D., Lalush D.S., Tsui B.M.W., and Gullberg G.T. "Evaluation of Myocardial Defect Detection between Parallel-Hole and Fan Beam SPECT Using Hotelling Trace", IEEE Trans. Nucl. Science, Vol. 45, pp. 2205-2210, 1997.
    • (1997) IEEE Trans. Nucl. Science , vol.45 , pp. 2205-2210
    • Wollenweber, S.D.1    Lalush, D.S.2    Tsui, B.M.W.3    Gullberg, G.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.