메뉴 건너뛰기




Volumn 6143 I, Issue , 2006, Pages

Optimization of retrospective respiratory-gated high speed micro-CT for free-breathing mice

Author keywords

Lung physiology; Optimization; Retrospective respiratory gating; Small animal imaging; Volume micro computed tomography

Indexed keywords

BIODIVERSITY; COMPUTERIZED TOMOGRAPHY; IMAGE RECONSTRUCTION; MOTION ESTIMATION; OPTICAL RESOLVING POWER; PHYSIOLOGY;

EID: 33745342428     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.653993     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 2
    • 0035288499 scopus 로고    scopus 로고
    • A review of high-resolution x-ray computed tomography and other imaging modalities for small-animal research
    • M. J. Paulus, S. S. Gleason, M. E. Easterly, C. J. Foltz, "A review of high-resolution x-ray computed tomography and other imaging modalities for small-animal research," Lab Animal, 30, pp. 36-45, 2001.
    • (2001) Lab Animal , vol.30 , pp. 36-45
    • Paulus, M.J.1    Gleason, S.S.2    Easterly, M.E.3    Foltz, C.J.4
  • 3
    • 0034111937 scopus 로고    scopus 로고
    • High resolution computed tomography and MRI for monitoring lung tumor growth in mice undergoing radioimmunotherapy: Correlation with histology
    • S. J. Kennel, I. A. Davis, J. Branning, H. Pan, G. W. Kabalka, and M. J. Paulus, "High resolution computed tomography and MRI for monitoring lung tumor growth in mice undergoing radioimmunotherapy: correlation with histology," Med Phys, 27, pp. 1101-7, 2000.
    • (2000) Med Phys , vol.27 , pp. 1101-1107
    • Kennel, S.J.1    Davis, I.A.2    Branning, J.3    Pan, H.4    Kabalka, G.W.5    Paulus, M.J.6
  • 4
    • 4544333724 scopus 로고    scopus 로고
    • Improved method of in vivo respiratory-gated micro-CT imaging
    • E. B. Walters, K. Panda, J. A. Bankson, E. Brown, D. D. Cody, "Improved Method of in Vivo Respiratory-Gated Micro-CT Imaging," Phys Med Biol, 49, pp. 4163-72, 2004.
    • (2004) Phys Med Biol , vol.49 , pp. 4163-4172
    • Walters, E.B.1    Panda, K.2    Bankson, J.A.3    Brown, E.4    Cody, D.D.5
  • 6
    • 11244304503 scopus 로고    scopus 로고
    • Micro-CT with respiratory and cardiac gating
    • C. Badea, L. W. Hedlund, G. A. Johnson, "Micro-CT With Respiratory and Cardiac Gating," Med. Phys. 31, pp. 3324-9, 2004.
    • (2004) Med. Phys. , vol.31 , pp. 3324-3329
    • Badea, C.1    Hedlund, L.W.2    Johnson, G.A.3
  • 7
    • 0032794416 scopus 로고    scopus 로고
    • A method of endotracheal intubation and pulmonary functional assessment for repeated studies in mice
    • R. H. Brown, D. M. Walters, R. S. Greenberg, and W. Mitzner, "A method of endotracheal intubation and pulmonary functional assessment for repeated studies in mice," J Appl Physiol, 87, pp. 2362-5, 1999.
    • (1999) J Appl Physiol , vol.87 , pp. 2362-2365
    • Brown, R.H.1    Walters, D.M.2    Greenberg, R.S.3    Mitzner, W.4
  • 9
    • 4544287733 scopus 로고    scopus 로고
    • Dynamic small animal lung imaging via a postacquisition respiratory gating technique using micro-cone beam computed tomography
    • J. Hu, S. T. Haworth, R. C. Molthen, and C. A. Dawson, "Dynamic small animal lung imaging via a postacquisition respiratory gating technique using micro-cone beam computed tomography," Academic Radiology, 11, pp. 961-70, 2004.
    • (2004) Academic Radiology , vol.11 , pp. 961-970
    • Hu, J.1    Haworth, S.T.2    Molthen, R.C.3    Dawson, C.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.