Volumn 17, Issue 2, 2006, Pages 106-111

Avoidance of intermittent T-wave oversensing with device programming;Vermeidung von intermittierendem T-wellen-oversensing durch programmierung

Author keywords

ICD; Oversensing; Programming; T wave

Indexed keywords

ADULT; ARTICLE; CARDIOMYOPATHY; CARDIOVERSION; CASE REPORT; DEFIBRILLATOR; DEVICE; ELECTROCARDIOGRAM; ELECTRODE; HEART ARRHYTHMIA; HEART ELECTROPHYSIOLOGY; HEART FAILURE; HEART TRANSPLANTATION; HEART VENTRICLE ARRHYTHMIA; HUMAN; IMPLANTATION; MALE; T WAVE;

EID: 33745318838     PISSN: 09387412     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00399-006-0481-5     Document Type: Article
Times cited : (2)

References (8)
  • 2
    • 0035113587 scopus 로고    scopus 로고
    • Avoiding inappropriate ventricular tachycardia detection due to T-wave oversensing in an implantable cardioverter defibrillator: A novel application of the electrogram width criterion
    • Duru F, Bauersfeld U, Candinas R (2001) Avoiding inappropriate ventricular tachycardia detection due to T-wave oversensing in an implantable cardioverter defibrillator: a novel application of the electrogram width criterion. Europace 3:80-84
    • (2001) Europace , vol.3 , pp. 80-84
    • Duru, F.1    Bauersfeld, U.2    Candinas, R.3
  • 5
    • 0029862971 scopus 로고    scopus 로고
    • Problems in managing patients with long QT-syndrome and implantable cardioverter defibrillators: A report of two cases
    • Perry GY, Kosar EM (1996) Problems in managing patients with long QT-syndrome and implantable cardioverter defibrillators: a report of two cases. Pacing Clin Electrophysiol 19:863-867
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 863-867
    • Perry, G.Y.1    Kosar, E.M.2
  • 6
    • 0347992796 scopus 로고    scopus 로고
    • Congenital short QT-syndrome and implantable cardioverter defibrillator treatment: Inherent risk for inappropriate shock delivery
    • Schimpf R, Wolpert C, Bianchi F, Giustetto C, Gaita F, Bauersfeld U, Borggrefe M (2003) Congenital short QT-syndrome and implantable cardioverter defibrillator treatment: inherent risk for inappropriate shock delivery. J Cardiovasc Electrophysiol 14:1273-1277
    • (2003) J Cardiovasc Electrophysiol , vol.14 , pp. 1273-1277
    • Schimpf, R.1    Wolpert, C.2    Bianchi, F.3    Giustetto, C.4    Gaita, F.5    Bauersfeld, U.6    Borggrefe, M.7
  • 7
    • 0034935372 scopus 로고    scopus 로고
    • Inappropriate discharges from an intravenous implantable cardioverter defibrillator due to T-wave oversensing
    • Washizuka T, Chinushi M, Kasai H, Watanabe H, Tagawa M, Hosaka Y, Abe A, Aizawa Y (2001) Inappropriate discharges from an intravenous implantable cardioverter defibrillator due to T-wave oversensing. Jpn Circ J 65:685-687
    • (2001) Jpn Circ J , vol.65 , pp. 685-687
    • Washizuka, T.1    Chinushi, M.2    Kasai, H.3    Watanabe, H.4    Tagawa, M.5    Hosaka, Y.6    Abe, A.7    Aizawa, Y.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.