메뉴 건너뛰기




Volumn 6093, Issue , 2006, Pages

Reliable long-term continuous blood glucose monitoring for patients in critical care using micro-dialysis and infrared spectrometry

Author keywords

Blood glucose analysis; Continuous monitoring; Infrared spectroscopy; Micro dialysis

Indexed keywords

BLOOD GLUCOSE ANALYSIS; CONTINUOUS MONITORING; MICRO-DIALYSIS;

EID: 33745303301     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.650833     Document Type: Conference Paper
Times cited : (6)

References (16)
  • 1
    • 0002135689 scopus 로고    scopus 로고
    • Clinical applications of near- and mid-infrared spectroscopy
    • H.-U. Gremlich and B. Van, Eds., Marcel Dekker, New York, Chap. 8
    • H.M. Heise, "Clinical applications of near- and mid-infrared spectroscopy," in: Infrared and Roman Spectroscopy of Biological Materials, H.-U. Gremlich and B. Van, Eds., Marcel Dekker, New York, Chap. 8, pp. 259-322 (2001).
    • (2001) Infrared and Roman Spectroscopy of Biological Materials , pp. 259-322
    • Heise, H.M.1
  • 2
    • 17444376049 scopus 로고    scopus 로고
    • Nanoliter serum sample analysis by mid-infrared spectroscopy for minimally invasive blood glucose monitoring
    • E. Diessel, P. Kamphaus, K. Grothe, R. Kurte, U. Damm, H.M. Heise, "Nanoliter serum sample analysis by mid-infrared spectroscopy for minimally invasive blood glucose monitoring," Appl. Spectrosc. 59 (4), 442-451 (2005).
    • (2005) Appl. Spectrosc. , vol.59 , Issue.4 , pp. 442-451
    • Diessel, E.1    Kamphaus, P.2    Grothe, K.3    Kurte, R.4    Damm, U.5    Heise, H.M.6
  • 4
    • 0024731167 scopus 로고
    • Multivariate determination of glucose in whole blood by attenuated total reflection infrared spectroscopy
    • H.M. Heise, R. Marbach, G. Janatsch and J.D. Kruse-Jarres, "Multivariate determination of glucose in whole blood by attenuated total reflection infrared spectroscopy," Anal. Chem. 61, 2009-2015 (1989).
    • (1989) Anal. Chem. , vol.61 , pp. 2009-2015
    • Heise, H.M.1    Marbach, R.2    Janatsch, G.3    Kruse-Jarres, J.D.4
  • 5
    • 0024731130 scopus 로고
    • Multivariate calibration for assays in clinical chemistry using attenuated total reflection infrared spectra of human blood plasma
    • G. Janatsch, J.D. Kruse-Jarres, R. Marbach and H.M. Heise, "Multivariate calibration for assays in clinical chemistry using attenuated total reflection infrared spectra of human blood plasma," Anal. Chem. 61, 2016-2023 (1989).
    • (1989) Anal. Chem. , vol.61 , pp. 2016-2023
    • Janatsch, G.1    Kruse-Jarres, J.D.2    Marbach, R.3    Heise, H.M.4
  • 7
    • 0037289774 scopus 로고    scopus 로고
    • Determination of glucose in whole blood samples by mid-infrared spectroscopy
    • Y.J. Kim, S. Hahn, G. Yoon, "Determination of glucose in whole blood samples by mid-infrared spectroscopy," Appl. Optics 42 (4), 745-749 (2003).
    • (2003) Appl. Optics , vol.42 , Issue.4 , pp. 745-749
    • Kim, Y.J.1    Hahn, S.2    Yoon, G.3
  • 8
    • 0038445922 scopus 로고    scopus 로고
    • The use of Fourier-transform infrared spectroscopy for the quantitative determination of glucose concentration in whole blood
    • Y.C. Shen, A.G. Davies, E.H. Linfield, T.S. Elsey, P.F. Taday, D.D. Arnone, "The use of Fourier-transform infrared spectroscopy for the quantitative determination of glucose concentration in whole blood," Phys. Med. Biol. 48, 2023-2032 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , pp. 2023-2032
    • Shen, Y.C.1    Davies, A.G.2    Linfield, E.H.3    Elsey, T.S.4    Taday, P.F.5    Arnone, D.D.6
  • 9
    • 1842847233 scopus 로고    scopus 로고
    • Using two discrete frequencies within the middle infrared to quantitatively determine glucose in serum
    • W.B. Martin, S. Mirov, R. Venugopalan, "Using two discrete frequencies within the middle infrared to quantitatively determine glucose in serum,"J. Biomed. Optics 7 (4), 613-617 (2002).
    • (2002) J. Biomed. Optics , vol.7 , Issue.4 , pp. 613-617
    • Martin, W.B.1    Mirov, S.2    Venugopalan, R.3
  • 11
    • 25144448749 scopus 로고    scopus 로고
    • Ex-vivo determination of blood glucose by microdialysis in combination with infrared attenuated total reflection spectroscopy
    • H.M. Heise, A. Bittner, T. Koschinsky, F.A. Gries, "Ex-vivo determination of blood glucose by microdialysis in combination with infrared attenuated total reflection spectroscopy," Fresenius' J. Anal. Chem. 359, 83-87 (1997).
    • (1997) Fresenius' J. Anal. Chem. , vol.359 , pp. 83-87
    • Heise, H.M.1    Bittner, A.2    Koschinsky, T.3    Gries, F.A.4
  • 12
    • 1242309457 scopus 로고    scopus 로고
    • Determination of urea, glucose, and phosphate in dialysate with Fourier transform infrared spectroscopy
    • P.S. Jensen, J. Bak, S. Ladefoged, S. Andersson-Engels, "Determination of urea, glucose, and phosphate in dialysate with Fourier transform infrared spectroscopy," Spectrochim. Acta. A 60 (4), 899-905 (2004).
    • (2004) Spectrochim. Acta. A , vol.60 , Issue.4 , pp. 899-905
    • Jensen, P.S.1    Bak, J.2    Ladefoged, S.3    Andersson-Engels, S.4
  • 13
    • 22744456845 scopus 로고    scopus 로고
    • Middle infrared, quantum cascade laser optoelectronic absorption system for monitoring glucose in serum
    • W.B. Martin, S. Mirow, R. Venugopalan, "Middle infrared, quantum cascade laser optoelectronic absorption system for monitoring glucose in serum," Appl. Spectrosc. 59 (7), 881-884 (2005).
    • (2005) Appl. Spectrosc. , vol.59 , Issue.7 , pp. 881-884
    • Martin, W.B.1    Mirow, S.2    Venugopalan, R.3
  • 14
    • 25144453433 scopus 로고    scopus 로고
    • Rapid and reliable spectral variable selection for statistical calibrations based on PLS-regression vector choices
    • H.M. Heise, A. Bittner, "Rapid and reliable spectral variable selection for statistical calibrations based on PLS-regression vector choices," Fresenius' J. Anal. Chem. 359, 93-99 (1997).
    • (1997) Fresenius' J. Anal. Chem. , vol.359 , pp. 93-99
    • Heise, H.M.1    Bittner, A.2
  • 15
    • 3342981187 scopus 로고    scopus 로고
    • Evaluating the accuracy of continuous glucose-monitoring sensors - Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data
    • B.P. Kovatchev, L.A. Gonder-Frederick, D.J. Cox, W.L. Clarke, "Evaluating the accuracy of continuous glucose-monitoring sensors - Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data," Diabetes Care 27, 1922-1928 (2004).
    • (2004) Diabetes Care , vol.27 , pp. 1922-1928
    • Kovatchev, B.P.1    Gonder-Frederick, L.A.2    Cox, D.J.3    Clarke, W.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.