Optic sharp edge or convexity: comparison of effects on posterior capsular opacification
Nagata T., and Watanabe I. Optic sharp edge or convexity: comparison of effects on posterior capsular opacification. Jpn J Ophthalmol 40 (1996) 397-403
Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule
Nishi O., and Nishi K. Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule. J Cataract Refract Surg 25 (1999) 521-526
Changes in posterior capsule opacification after poly(methyl methacrylate), silicone, and acrylic intraocular lens implantation
Hayashi K., Hayashi H., Nakao F., and Hayashi F. Changes in posterior capsule opacification after poly(methyl methacrylate), silicone, and acrylic intraocular lens implantation. J Cataract Refract Surg 27 (2001) 817-824
The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery
discussion, 54-55
Hollick E.J., Spalton D.J., Ursell P.G., et al. The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery. Ophthalmology 106 (1999) 49-54 discussion, 54-55
A systematic overview of the incidence of posterior capsule opacification
Schaumberg D.A., Dana M.R., Christen W.G., and Glynn R.J. A systematic overview of the incidence of posterior capsule opacification. Ophthalmology 105 (1998) 1213-1221
UV-ozone modification of plasma-polymerised acetonitrile films for enhanced cell attachment
Davidson M.R., Mitchell S.A., and Bradley R.H. UV-ozone modification of plasma-polymerised acetonitrile films for enhanced cell attachment. Colloids Surf B Biointerfaces 34 (2004) 213-219
Evaluation of a 3-piece silicone intraocular lens with poly(methyl methacrylate) haptics
Linnola R.J., and Holst A. Evaluation of a 3-piece silicone intraocular lens with poly(methyl methacrylate) haptics. J Cataract Refract Surg 24 (2001) 1509-1514
Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study
Oshika T., Nagata T., and Ishii Y. Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study. Br J Ophthalmol 82 (1998) 549-553
Iida T. [Effect of adhesion properties of UV curing adhesive by UV ozone surface modification]. [Japanese] Setchaku = Technology on Adhesion and Sealing 2002; 46:207-210
11
33645644882
Cell adhesion on the surface preadsorbed with fibronectin and albumin
Arima Y., Horikawa T., and Iwata H. Cell adhesion on the surface preadsorbed with fibronectin and albumin. Polymer Preprints 54 (2005) 2244. http://www.polyacs.org/main/preprintsonline.shtml
Photoactivation of a substrate for cell adhesion under standard fluorescence microscopes
Nakanishi J., Kikuchi Y., Takarada T., et al. Photoactivation of a substrate for cell adhesion under standard fluorescence microscopes. J Am Chem Soc 126 (2004) 16314-16315
Nakamae K, Yamaguchio K. [Mobility of molecular chain on surface of polymer material]. [Japanese] Kobunshi Kako = Polymer Applications 1993; 42:522-525
* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.