메뉴 건너뛰기




Volumn 10, Issue 3, 2006, Pages 202-205

Ultrasound Biomicroscopy in Strabismus Reoperations

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BIOMICROSCOPY; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; EVALUATION; EXTRAOCULAR MUSCLE; FEMALE; GENERAL ANESTHESIA; HUMAN; MALE; PREOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; REOPERATION; SCHOOL CHILD; STRABISMUS; TOPICAL ANESTHESIA;

EID: 33745263233     PISSN: 10918531     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jaapos.2006.01.209     Document Type: Article
Times cited : (34)

References (10)
  • 1
    • 0018571696 scopus 로고
    • Reoperation in strabismus
    • Helveston E. Reoperation in strabismus. Ophthalmology 86 (1979) 1379-1388
    • (1979) Ophthalmology , vol.86 , pp. 1379-1388
    • Helveston, E.1
  • 2
    • 0032783653 scopus 로고    scopus 로고
    • Quantitative CT of the orbit in Graves' disease
    • Ozgen A., Alp M.N., Ariyurek M., et al. Quantitative CT of the orbit in Graves' disease. Br J Radiol 72 (1999) 757-762
    • (1999) Br J Radiol , vol.72 , pp. 757-762
    • Ozgen, A.1    Alp, M.N.2    Ariyurek, M.3
  • 3
    • 0028085423 scopus 로고
    • Comparison of standardized echography with magnetic resonance imaging to measure extraocular muscle size
    • Demer J.L., and Kerman B.M. Comparison of standardized echography with magnetic resonance imaging to measure extraocular muscle size. Am J Ophthalmol 118 (1994) 351-361
    • (1994) Am J Ophthalmol , vol.118 , pp. 351-361
    • Demer, J.L.1    Kerman, B.M.2
  • 4
    • 0031468199 scopus 로고    scopus 로고
    • High-resolution magnetic resonance imaging of the normal extraocular musculature
    • Ettl A., Kramer J., Daxer A., and Koornneef L. High-resolution magnetic resonance imaging of the normal extraocular musculature. Eye 11 (1997) 793-797
    • (1997) Eye , vol.11 , pp. 793-797
    • Ettl, A.1    Kramer, J.2    Daxer, A.3    Koornneef, L.4
  • 6
    • 0020421285 scopus 로고
    • The use of ultrasonography in determining the amount of extraocular muscle surgery in strabismus
    • Gillies W.E., and McIndoe A. The use of ultrasonography in determining the amount of extraocular muscle surgery in strabismus. Aust J Ophthalmol 10 (1982) 191-194
    • (1982) Aust J Ophthalmol , vol.10 , pp. 191-194
    • Gillies, W.E.1    McIndoe, A.2
  • 7
    • 0037309983 scopus 로고    scopus 로고
    • Ultrasound of the horizontal rectus muscle insertion sites. implications in preoperative assessment of strabismus
    • Tamburrelli C., Salgarello T., Vaiano A.S., et al. Ultrasound of the horizontal rectus muscle insertion sites. implications in preoperative assessment of strabismus. Invest Ophthalmol Vis Sci 44 (2003) 618-622
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 618-622
    • Tamburrelli, C.1    Salgarello, T.2    Vaiano, A.S.3
  • 8
    • 0036597980 scopus 로고    scopus 로고
    • Evaluation of the ultrasound biomicroscope in strabismus surgery
    • Watts P., Smith D., Mackeen L., et al. Evaluation of the ultrasound biomicroscope in strabismus surgery. J of AAPOS 6 (2002) 187-190
    • (2002) J of AAPOS , vol.6 , pp. 187-190
    • Watts, P.1    Smith, D.2    Mackeen, L.3
  • 10
    • 0034463767 scopus 로고    scopus 로고
    • Normative measurements of orbital structures using MRI
    • Ozgen A., and Aydingoz U. Normative measurements of orbital structures using MRI. J Comput Assist Tomogr 24 (2000) 493-496
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 493-496
    • Ozgen, A.1    Aydingoz, U.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.