메뉴 건너뛰기




Volumn 64, Issue 1, 2006, Pages 101-103

Endoluminal endosurgery: rivet application in flexible endoscopy

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTIC METHOD; ANIMAL TISSUE; ARTICLE; CONTROLLED STUDY; FEASIBILITY STUDY; GASTROINTESTINAL ENDOSCOPY; GASTROINTESTINAL TRACT; GASTROSCOPE; LACERATION; NONHUMAN; OUTCOME ASSESSMENT; PILOT STUDY; PRIORITY JOURNAL; RIVET; SAMPLE; STOMACH; SURGICAL INSTRUMENT; TISSUE REPAIR; WOUND CLOSURE;

EID: 33745237184     PISSN: 00165107     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.gie.2005.10.031     Document Type: Article
Times cited : (26)

References (9)
  • 1
    • 4744374138 scopus 로고    scopus 로고
    • Solutions to some difficulties in sewing at flexible endoscopy
    • [abstract] AB148
    • Swain P., Fritscher-Ravens A., Mosse S., et al. Solutions to some difficulties in sewing at flexible endoscopy. [abstract]. Gastrointest Endosc 59 (2004) AB148
    • (2004) Gastrointest Endosc , vol.59
    • Swain, P.1    Fritscher-Ravens, A.2    Mosse, S.3
  • 2
    • 4744368169 scopus 로고    scopus 로고
    • Endoscopic clip application for closure of esophageal perforations caused by EMR
    • Shimizu Y., Kato M., Yamamoto J., et al. Endoscopic clip application for closure of esophageal perforations caused by EMR. Gastrointest Endosc 60 (2004) 636-639
    • (2004) Gastrointest Endosc , vol.60 , pp. 636-639
    • Shimizu, Y.1    Kato, M.2    Yamamoto, J.3
  • 3
    • 0141817851 scopus 로고    scopus 로고
    • Transluminal endosurgery: single lumen access anastomotic device for flexible endoscopy
    • Fritscher-Ravens A., Mosse A., Mukherjee D., et al. Transluminal endosurgery: single lumen access anastomotic device for flexible endoscopy. Gastrointest Endosc 58 (2003) 585-591
    • (2003) Gastrointest Endosc , vol.58 , pp. 585-591
    • Fritscher-Ravens, A.1    Mosse, A.2    Mukherjee, D.3
  • 4
    • 0035315779 scopus 로고    scopus 로고
    • Transoral, flexible endoscopic suturing for treatment of GERD: a multicenter trial
    • Filipi C., Lehman G., Rothstein R., et al. Transoral, flexible endoscopic suturing for treatment of GERD: a multicenter trial. Gastrointest Endosc 53 (2001) 416-422
    • (2001) Gastrointest Endosc , vol.53 , pp. 416-422
    • Filipi, C.1    Lehman, G.2    Rothstein, R.3
  • 5
    • 1042278067 scopus 로고    scopus 로고
    • Endoclips for GI endoscopy
    • Raju G., and Gajula L. Endoclips for GI endoscopy. Gastrointest Endosc 59 (2004) 267-279
    • (2004) Gastrointest Endosc , vol.59 , pp. 267-279
    • Raju, G.1    Gajula, L.2
  • 6
    • 33745273751 scopus 로고    scopus 로고
    • Witte F, Crostack HA, Nellesen J, et al. Characterization of a magnesium alloy as a degradable bone implant material by synchrotron-based microtomography. Stuttgart: European Society for Biomaterials; 18th European Conference on Biomaterials 2003; T067.
  • 8
    • 0038354711 scopus 로고    scopus 로고
    • Biocompatibility of corroding tungsten coils: in vitro assessment of degradation kinetics and cytotoxicity on human cells
    • Peuster M., Fink C., and von Schnakenburg C. Biocompatibility of corroding tungsten coils: in vitro assessment of degradation kinetics and cytotoxicity on human cells. Biomaterials 24 (2003) 4057-4061
    • (2003) Biomaterials , vol.24 , pp. 4057-4061
    • Peuster, M.1    Fink, C.2    von Schnakenburg, C.3
  • 9
    • 11144301699 scopus 로고    scopus 로고
    • In vivo corrosion of four magnesium alloys and the associated bone response
    • Witte F., Kaese V., Haferkamp H., et al. In vivo corrosion of four magnesium alloys and the associated bone response. Biomaterials 26 (2005) 3557-3563
    • (2005) Biomaterials , vol.26 , pp. 3557-3563
    • Witte, F.1    Kaese, V.2    Haferkamp, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.