메뉴 건너뛰기




Volumn 11, Issue 1, 2006, Pages 37-42

Performance of the automated BpTRU™ measurement device in the assessment of white-coat hypertension and white-coat effect

Author keywords

Automated blood pressure; Blood pressure measurement; BpTRU; Clinical trial; Hypertension; Misclassification; White coat effect; White coat hypertension

Indexed keywords

ADULT; ANALYTICAL ERROR; ARTICLE; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; CARDIOVASCULAR EQUIPMENT; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; GENERAL PRACTITIONER; HUMAN; HYPERTENSION; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; NURSE; OSCILLOMETRY; PRIORITY JOURNAL; TUNICA ALBUGINEA; WHITE COAT EFFECT; WHITE COAT HYPERTENSION; AGED; AMBULATORY CARE; BLOOD PRESSURE; DIAGNOSTIC ERROR; EVALUATION; INSTRUMENTATION; MIDDLE AGED; PSYCHOLOGICAL ASPECT; STANDARD;

EID: 33745163278     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.mbp.0000189794.36230.a7     Document Type: Article
Times cited : (49)

References (18)
  • 1
    • 0033543067 scopus 로고    scopus 로고
    • Accurate blood pressure measurement: Why does it matter?
    • Campbell NR, McKay DW. Accurate blood pressure measurement: why does it matter? Can Med Assoc J 1999; 161:277-278.
    • (1999) Can Med Assoc J , vol.161 , pp. 277-278
    • Campbell, N.R.1    McKay, D.W.2
  • 2
    • 0018182591 scopus 로고
    • Increased absenteeism from work after detection and labeling of hypertensive patients
    • Haynes RB, Sackett DL, Taylor DW, Gibson ES, Johnson AL. Increased absenteeism from work after detection and labeling of hypertensive patients. N Engl J Med 1978; 299:741-744.
    • (1978) N Engl J Med , vol.299 , pp. 741-744
    • Haynes, R.B.1    Sackett, D.L.2    Taylor, D.W.3    Gibson, E.S.4    Johnson, A.L.5
  • 4
    • 0023476629 scopus 로고
    • Hypertension: Questions of prevalence, diagnosis, and management
    • Medical Technology and Practice Patterns Institute. Hypertension: questions of prevalence, diagnosis, and management. J Clin Hypertens 1987; 3:757-767.
    • (1987) J Clin Hypertens , vol.3 , pp. 757-767
  • 5
    • 1442326141 scopus 로고    scopus 로고
    • The 2004 Canadian Hypertension Education Program recommendations for the management of hypertension. Part I: Blood pressure measurement, diagnosis and assessment of risk
    • Hemmelgarn BR, Zarnke KB, Campbell NR, Feldman RD, McKay DW, McAlister FA, et al. The 2004 Canadian Hypertension Education Program recommendations for the management of hypertension. Part I: blood pressure measurement, diagnosis and assessment of risk. Can J Cardiol 2004; 20:31-40.
    • (2004) Can J Cardiol , vol.20 , pp. 31-40
    • Hemmelgarn, B.R.1    Zarnke, K.B.2    Campbell, N.R.3    Feldman, R.D.4    McKay, D.W.5    McAlister, F.A.6
  • 6
    • 0347423198 scopus 로고    scopus 로고
    • Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure
    • Chobanian AV, Bakris GL, Black HR, Cushman WC, Green LA, Izzo JL Jr. et al. Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. Hypertension 2003;42:1206-1252.
    • (2003) Hypertension , vol.42 , pp. 1206-1252
    • Chobanian, A.V.1    Bakris, G.L.2    Black, H.R.3    Cushman, W.C.4    Green, L.A.5    Izzo Jr., J.L.6
  • 7
    • 0032759664 scopus 로고    scopus 로고
    • Canadian hypertension society guidelines for ambulatory blood pressure monitoring
    • Myers MG, Haynes RB, Rabkin SW. Canadian hypertension society guidelines for ambulatory blood pressure monitoring. Am J Hypertens 1999; 12:1149-1157.
    • (1999) Am J Hypertens , vol.12 , pp. 1149-1157
    • Myers, M.G.1    Haynes, R.B.2    Rabkin, S.W.3
  • 8
    • 19944429836 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals. Part 1: Blood pressure measurement in humans: A statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research
    • Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood pressure measurement in humans and experimental animals. Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension 2005; 45:142-161.
    • (2005) Hypertension , vol.45 , pp. 142-161
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3    Falkner, B.E.4    Graves, J.5    Hill, M.N.6
  • 10
    • 0029063986 scopus 로고
    • Prevalence of white coat effect in treated hypertensive patients in the community
    • Myers MG, Oh PI, Reeves RA, Joyner CD. Prevalence of white coat effect in treated hypertensive patients in the community. Am J Hypertens 1995; 8:591-597.
    • (1995) Am J Hypertens , vol.8 , pp. 591-597
    • Myers, M.G.1    Oh, P.I.2    Reeves, R.A.3    Joyner, C.D.4
  • 12
    • 0033546609 scopus 로고    scopus 로고
    • Predicting cardiovascular risk using conventional vs ambulatory blood pressure in older patients with systolic hypertension
    • Systolic Hypertension in Europe Trial Investigators
    • Staessen JA, Thijs L, Fagard R, O'Brien ET, Clement D, de Leeuw PW, et al. Predicting cardiovascular risk using conventional vs ambulatory blood pressure in older patients with systolic hypertension. Systolic Hypertension in Europe Trial Investigators. JAMA 1999; 282:539-546.
    • (1999) JAMA , vol.282 , pp. 539-546
    • Staessen, J.A.1    Thijs, L.2    Fagard, R.3    O'Brien, E.T.4    Clement, D.5    De Leeuw, P.W.6
  • 13
    • 0034889766 scopus 로고    scopus 로고
    • Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor
    • Wright JM, Mattu GS, Perry TL Jr, Gelferc ME, Strange KD, Zorn A, et al. Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor. Blood Press Monit 2001; 6:161-165.
    • (2001) Blood Press Monit , vol.6 , pp. 161-165
    • Wright, J.M.1    Mattu, G.S.2    Perry Jr., T.L.3    Gelferc, M.E.4    Strange, K.D.5    Zorn, A.6
  • 14
    • 1842427421 scopus 로고    scopus 로고
    • Overall accuracy of the BpTRU: An automated electronic blood pressure device
    • Mattu GS, Heran BS, Wright JM. Overall accuracy of the BpTRU: an automated electronic blood pressure device. Blood Press Monit 2004; 9:47-52.
    • (2004) Blood Press Monit , vol.9 , pp. 47-52
    • Mattu, G.S.1    Heran, B.S.2    Wright, J.M.3
  • 15
    • 0035527544 scopus 로고    scopus 로고
    • State of the market for devices for blood pressure measurement
    • O'Brien E. State of the market for devices for blood pressure measurement. Blood Press Monit 2001; 6:281-286.
    • (2001) Blood Press Monit , vol.6 , pp. 281-286
    • O'Brien, E.1
  • 16
    • 0037528711 scopus 로고    scopus 로고
    • Use of an automated blood pressure recording device, the BpTRU, to reduce the 'white coat effect' in routine practice
    • Myers MG, Valdivieso MA. Use of an automated blood pressure recording device, the BpTRU, to reduce the 'white coat effect' in routine practice. Am J Hypertens 2003; 16:494-497.
    • (2003) Am J Hypertens , vol.16 , pp. 494-497
    • Myers, M.G.1    Valdivieso, M.A.2
  • 17
    • 0032126006 scopus 로고    scopus 로고
    • White coat effect detected using self-monitoring of blood pressure at home: Comparison with ambulatory blood pressure
    • Stergiou GS, Zourbaki AS, Skeva II, Mountokalakis TD. White coat effect detected using self-monitoring of blood pressure at home: comparison with ambulatory blood pressure. Am J Hypertens 1998; 11:820-827.
    • (1998) Am J Hypertens , vol.11 , pp. 820-827
    • Stergiou, G.S.1    Zourbaki, A.S.2    Skeva, I.I.3    Mountokalakis, T.D.4
  • 18
    • 0347601672 scopus 로고    scopus 로고
    • Clinical decision-making in hypertension using an automated (BpTRU) measurement device
    • Graves JW, Nash C, Burger K, Bailey K, Sheps SG. Clinical decision-making in hypertension using an automated (BpTRU) measurement device. J Hum Hypertens 2003; 17:823-827.
    • (2003) J Hum Hypertens , vol.17 , pp. 823-827
    • Graves, J.W.1    Nash, C.2    Burger, K.3    Bailey, K.4    Sheps, S.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.