Volumn 6144 III, Issue , 2006, Pages

The influence of CT dose and reconstruction parameters on automated detection of small pulmonary nodules

Author keywords

Computed Tomography (CT); Computer Aided Detection (CAD); Dose; Imaging Physics; LIDC; Reconstruction Kernel; Small Lung Nodules

Indexed keywords

COMPUTER AIDED DETECTION (CAD); DOSE; IMAGING PHYSICS; LIDC; RECONSTRUCTION KERNEL; SMALL LUNG NODULES;

EID: 33745130050     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.658663     Document Type: Conference Paper
Times cited : (5)

References (16)
  • 3
    • 0028298099 scopus 로고
    • A comparison of conventional and spiral CT: An experimental study on the detection of spherical lesions
    • W.A. Kalender, A. Polacin, and C. Suss. "A comparison of conventional and spiral CT: an experimental study on the detection of spherical lesions." J Comput Assist Tomogr 18, 167-176, 1994.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 167-176
    • Kalender, W.A.1    Polacin, A.2    Suss, C.3
  • 4
    • 0027245609 scopus 로고
    • Pulmonary nodules: Detection with thick-section spiral CT versus conventional CT
    • M. Remy-Jardin, J. Remy, F. Giraud, and C.H. Marquette. "Pulmonary nodules: detection with thick-section spiral CT versus conventional CT." Radiology 187, 513-520, 1993.
    • (1993) Radiology , vol.187 , pp. 513-520
    • Remy-Jardin, M.1    Remy, J.2    Giraud, F.3    Marquette, C.H.4
  • 6
    • 5644282714 scopus 로고    scopus 로고
    • Application of the LDM algorithm to identify small lung nodules on low-dose MSCT scans
    • B. Zhao, M.S. Ginsberg, R.A. Lefkowitz, L. Jiang, C. Cooper, and L.H. Schwartz. "Application of the LDM algorithm to identify small lung nodules on low-dose MSCT scans. Proc SPIE 5370, 818-823, 2004.
    • (2004) Proc SPIE , vol.5370 , pp. 818-823
    • Zhao, B.1    Ginsberg, M.S.2    Lefkowitz, R.A.3    Jiang, L.4    Cooper, C.5    Schwartz, L.H.6
  • 7
    • 0037260266 scopus 로고    scopus 로고
    • Lung micronodules: Automated method for detection at thin-section CT-initial experience
    • M.S. Brown, J.G. Goldin, R.D. Suh, M.F. McNitt-Gray, J.W. Sayre, and D.R. Aberle. "Lung micronodules: automated method for detection at thin-section CT-initial experience", Radiology 226, 256-262, 2003.
    • (2003) Radiology , vol.226 , pp. 256-262
    • Brown, M.S.1    Goldin, J.G.2    Suh, R.D.3    McNitt-Gray, M.F.4    Sayre, J.W.5    Aberle, D.R.6
  • 8
    • 0037342984 scopus 로고    scopus 로고
    • Automated detection of lung nodules in CT scans: Effect of image reconstruction algorithm
    • S.G. Armato III, M.B. Altman, and P.J. La Rivière. "Automated detection of lung nodules in CT scans: effect of image reconstruction algorithm," Med. Phys., 30(3), 461-472, 2003.
    • (2003) Med. Phys. , vol.30 , Issue.3 , pp. 461-472
    • Armato III, S.G.1    Altman, M.B.2    La Rivière, P.J.3
  • 9
    • 12544250044 scopus 로고    scopus 로고
    • Computer-assisted detection of pulmonary nodules: Evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings
    • K. Marten, A. Grillhösl, T. Seyfarth, S. Obenauer, E.J. Rummeny, and C. Engelke. "Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings", Eur Radiol 15, 203-212, 2005.
    • (2005) Eur Radiol , vol.15 , pp. 203-212
    • Marten, K.1    Grillhösl, A.2    Seyfarth, T.3    Obenauer, S.4    Rummeny, E.J.5    Engelke, C.6
  • 10
    • 20744443150 scopus 로고    scopus 로고
    • Automated detection of pulmonary nodules on CT images: Effect of section thickness and reconstruction interval-initial results
    • J.S. Kim, J.H. Kim, G. Cho, and K.T. Bae. "Automated detection of pulmonary nodules on CT images: effect of section thickness and reconstruction interval-initial results", Radiology, 236, 295-299 2005.
    • (2005) Radiology , vol.236 , pp. 295-299
    • Kim, J.S.1    Kim, J.H.2    Cho, G.3    Bae, K.T.4
  • 12
    • 23844513129 scopus 로고    scopus 로고
    • Tradeoffs in noise, resolution, and dose with reconstruction filter selection in lung nodule detection in CT
    • K.L. Boedeker and M.F. McNitt-Gray. "Tradeoffs in noise, resolution, and dose with reconstruction filter selection in lung nodule detection in CT" Proc. SPIE 5745, 695-703, 2005
    • (2005) Proc. SPIE , vol.5745 , pp. 695-703
    • Boedeker, K.L.1    McNitt-Gray, M.F.2
  • 14
    • 84858902492 scopus 로고    scopus 로고
    • ftp://ncicbfalcon.nci.nih.gov/lidc/


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.