메뉴 건너뛰기




Volumn 27, Issue 5, 2006, Pages

Factors limiting the application of electrical impedance tomography for identification of regional conductivity changes using scalp electrodes during epileptic seizures in humans

Author keywords

EIT; Epilepsy; Human measurements; Telemetry

Indexed keywords

BRAIN; DATA HANDLING; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; ELECTRODES; ELECTROENCEPHALOGRAPHY; ELECTROPHYSIOLOGY; NEUROPHYSIOLOGY; TELEMETERING EQUIPMENT;

EID: 33745120842     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/5/S14     Document Type: Conference Paper
Times cited : (72)

References (26)
  • 1
    • 0032189998 scopus 로고    scopus 로고
    • Identification of EEG events in the MR scanner: The problem of pulse artifact and a method for its subtraction
    • Allen P J, Polizzi G, Krakow K, Fish D R and Lemieux L 1998 Identification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtraction Neuroimage 8 229-39
    • (1998) Neuroimage , vol.8 , Issue.3 , pp. 229-239
    • Allen, P.J.1    Polizzi, G.2    Krakow, K.3    Fish, D.R.4    Lemieux, L.5
  • 2
    • 0142106311 scopus 로고    scopus 로고
    • Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method
    • Bagshaw A P et al 2003 Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method Neuroimage 20 752-64
    • (2003) Neuroimage , vol.20 , Issue.2 , pp. 752-764
    • Bagshaw, A.P.1    Al, E.2
  • 4
    • 0028337785 scopus 로고
    • Imaging of cortical spreading depression by EIT: Implications for localization of epileptic foci
    • Boone K, Lewis A M and Holder D S 1994 Imaging of cortical spreading depression by EIT: implications for localization of epileptic foci Physiol. Meas. 15 A189-98
    • (1994) Physiol. Meas. , vol.15 , Issue.2 A
    • Boone, K.1    Lewis, A.M.2    Holder, D.S.3
  • 6
    • 0013984336 scopus 로고
    • Impedance changes during epileptic seizures
    • Elazar Z, Kado R T and Adey W R 1966 Impedance changes during epileptic seizures Epilepsia 7 291-307
    • (1966) Epilepsia , vol.7 , pp. 291-307
    • Elazar, Z.1    Kado, R.T.2    Adey, W.R.3
  • 7
    • 0027257618 scopus 로고
    • Update on surgical treatment of the epilepsies. Summary of the Second International Palm Desert Conference on the Surgical treatment of the Epilepsies (1992)
    • Engel J Jr 1993 Update on surgical treatment of the epilepsies. Summary of the Second International Palm Desert Conference on the Surgical treatment of the Epilepsies (1992) Neurology 43 1612-17
    • (1993) Neurology , vol.43 , pp. 1612-1617
    • Engel, J.1
  • 8
    • 3042592569 scopus 로고    scopus 로고
    • Tissue resistance changes and the profile of synchronized neuronal activity during ictal events in the low-calcium model of epilepsy
    • Fox J E, Bikson M and Jefferys J G 2004 Tissue resistance changes and the profile of synchronized neuronal activity during ictal events in the low-calcium model of epilepsy J. Neurophysiol. 92 181-8
    • (2004) J. Neurophysiol. , vol.92 , Issue.1 , pp. 181-188
    • Fox, J.E.1    Bikson, M.2    Jefferys, J.G.3
  • 10
    • 0001195441 scopus 로고
    • Numerical tools for analysis and solution of Fredholm integral equations of the first kind
    • Handersen P C 1992 Numerical tools for analysis and solution of Fredholm integral equations of the first kind Inverse Problems 8 849-72
    • (1992) Inverse Problems , vol.8 , Issue.6 , pp. 849-872
    • Handersen, P.C.1
  • 11
    • 0032723169 scopus 로고    scopus 로고
    • Invasive EEG monitoring in children: When, where, and what?
    • Jayakar P 1999 Invasive EEG monitoring in children: when, where, and what? J. Clin. Neurophysiol. 16 408-18
    • (1999) J. Clin. Neurophysiol. , vol.16 , pp. 408-418
    • Jayakar, P.1
  • 15
    • 0036994840 scopus 로고    scopus 로고
    • Toolkit for three-dimensional electrical impedance tomography: A contribution to the electrical impedance tomography and diffuse optical reconstruction software project
    • Polydorides N and Lionheart W R B 2002 Toolkit for three-dimensional electrical impedance tomography: a contribution to the electrical impedance tomography and diffuse optical reconstruction software project Meas. Sci. Technol. 13 1871-83
    • (2002) Meas. Sci. Technol. , vol.13 , Issue.12 , pp. 1871-1883
    • Polydorides, N.1    Lionheart, W.R.B.2
  • 18
    • 0000816772 scopus 로고    scopus 로고
    • EIT images of electrically induced epileptic activity in anaesthetised rabbits
    • Rao A, Gibson A and Holder D S 1997 EIT images of electrically induced epileptic activity in anaesthetised rabbits Med. Biol. Eng. Comput. 35 3274
    • (1997) Med. Biol. Eng. Comput. , vol.35 , pp. 3274
    • Rao, A.1    Gibson, A.2    Holder, D.S.3
  • 19
    • 0034857509 scopus 로고    scopus 로고
    • Presurgical evaluation of epilepsy
    • Rosenow F and Luders H 2001 Presurgical evaluation of epilepsy Brain 124 1683-700
    • (2001) Brain , vol.124 , Issue.9 , pp. 1683-1700
    • Rosenow, F.1    Luders, H.2
  • 20
    • 17044387750 scopus 로고    scopus 로고
    • Geodesic photogrammetry for localizing sensor positions in dense-array EEG
    • Russell G S, Jeffrey E K, Poolman P, Luu P and Tucker D M 2005 Geodesic photogrammetry for localizing sensor positions in dense-array EEG Clin. Neurophysiol. 116 1130-40
    • (2005) Clin. Neurophysiol. , vol.116 , Issue.5 , pp. 1130-1140
    • Russell, G.S.1    Jeffrey, E.K.2    Poolman, P.3    Luu, P.4    Tucker, D.M.5
  • 22
    • 0035118995 scopus 로고    scopus 로고
    • Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank
    • Tidswell A T, Gibson A, Bayford R H and Holder D S 2001 Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank Physiol. Meas. 22 177-85
    • (2001) Physiol. Meas. , vol.22 , Issue.1 , pp. 177-185
    • Tidswell, A.T.1    Gibson, A.2    Bayford, R.H.3    Holder, D.S.4
  • 23
    • 23044500825 scopus 로고    scopus 로고
    • Generating accurate finite element meshes for the forward model of the human head in EIT
    • Tizzard A, Horesh L, Yerworth R J, Holder D S and Bayford R H 2005 Generating accurate finite element meshes for the forward model of the human head in EIT Physiol. Meas. 26 S251-61
    • (2005) Physiol. Meas. , vol.26 , Issue.2
    • Tizzard, A.1    Horesh, L.2    Yerworth, R.J.3    Holder, D.S.4    Bayford, R.H.5
  • 24
    • 0001678323 scopus 로고
    • Changes in the electrical conductivity of cerebral cortex during seizure activity
    • Van Harreveld A and Shade J P 1962 Changes in the electrical conductivity of cerebral cortex during seizure activity Exp. Neurol. 5 383-400
    • (1962) Exp. Neurol. , vol.5 , Issue.5 , pp. 383-400
    • Van Harreveld, A.1    Shade, J.P.2
  • 26
    • 0036171902 scopus 로고    scopus 로고
    • Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function
    • Yerworth R J, Bayford R H, Cusick G, Conway M and Holder D S 2002 Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function Physiol. Meas. 23 149-58
    • (2002) Physiol. Meas. , vol.23 , Issue.1 , pp. 149-158
    • Yerworth, R.J.1    Bayford, R.H.2    Cusick, G.3    Conway, M.4    Holder, D.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.