메뉴 건너뛰기




Volumn 21, Issue 4 SUPPL., 2006, Pages 121-125

Constrained Liners in Revision Total Hip Arthroplasty: An Overuse Syndrome. In the Affirmative

Author keywords

constrained liners; dislocation; failure; large femoral heads; revision

Indexed keywords

POLYETHYLENE;

EID: 33745079537     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2006.02.100     Document Type: Article
Times cited : (49)

References (17)
  • 1
    • 0027048727 scopus 로고
    • Operative correction of an unstable total hip arthroplasty
    • Daly P.J., and Morrey B.F. Operative correction of an unstable total hip arthroplasty. J Bone Joint Surg Am 74 (1992) 1334
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 1334
    • Daly, P.J.1    Morrey, B.F.2
  • 2
    • 0026098872 scopus 로고
    • Preliminary report on the S-ROM constraining acetabular insert: a retrospective clinical experience
    • Lombardi Jr. A.V., Mallory T.H., Kraus T.J., et al. Preliminary report on the S-ROM constraining acetabular insert: a retrospective clinical experience. Orthopedics 14 (1991) 297
    • (1991) Orthopedics , vol.14 , pp. 297
    • Lombardi Jr., A.V.1    Mallory, T.H.2    Kraus, T.J.3
  • 4
    • 0028276428 scopus 로고
    • Constrained acetabular cup disassembly
    • Fisher D.A., and Kiley K. Constrained acetabular cup disassembly. J Arthroplasty 9 (1994) 325
    • (1994) J Arthroplasty , vol.9 , pp. 325
    • Fisher, D.A.1    Kiley, K.2
  • 5
    • 0031925716 scopus 로고    scopus 로고
    • Failure of a constrained acetabular prosthesis of a total hip arthroplasty: a report of four cases
    • Kaper B.P., and Bernini P.M. Failure of a constrained acetabular prosthesis of a total hip arthroplasty: a report of four cases. J Bone Joint Surg Am 80 (1998) 561
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 561
    • Kaper, B.P.1    Bernini, P.M.2
  • 6
    • 26444572306 scopus 로고    scopus 로고
    • High failure rate of a constrained acetabular liner in revision total hip arthroplasty
    • Della Valle C.J., Chang D., Sporer S., et al. High failure rate of a constrained acetabular liner in revision total hip arthroplasty. J Arthroplasty 20 7 Suppl 3 (2005) 103
    • (2005) J Arthroplasty , vol.20 , Issue.7 SUPPL. 3 , pp. 103
    • Della Valle, C.J.1    Chang, D.2    Sporer, S.3
  • 7
    • 0031764303 scopus 로고    scopus 로고
    • Salvage of total hip instability with a constrained acetabular component
    • Goetz D.D., Capello W.N., Callaghan J.J., et al. Salvage of total hip instability with a constrained acetabular component. Clin Orthop 355 (1998) 171
    • (1998) Clin Orthop , vol.355 , pp. 171
    • Goetz, D.D.1    Capello, W.N.2    Callaghan, J.J.3
  • 8
    • 0031926423 scopus 로고    scopus 로고
    • Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component: a retrospective analysis of fifty-six cases
    • Goetz D.D., Capello W.N., Callaghan J.J., et al. Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component: a retrospective analysis of fifty-six cases. J Bone Joint Surg Am 80 (1998) 502
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 502
    • Goetz, D.D.1    Capello, W.N.2    Callaghan, J.J.3
  • 9
    • 8144224773 scopus 로고    scopus 로고
    • Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component
    • Goetz D.D., Bremner B.R.B., Callaghan J.J., et al. Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component. J Bone Joint Surg Am 86 (2004) 2419
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 2419
    • Goetz, D.D.1    Bremner, B.R.B.2    Callaghan, J.J.3
  • 10
    • 9644304525 scopus 로고    scopus 로고
    • Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty
    • Callaghan J.J., O'Rourke M.R., Goetz D.D., et al. Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty. Clin Orthop 429 (2004) 117
    • (2004) Clin Orthop , vol.429 , pp. 117
    • Callaghan, J.J.1    O'Rourke, M.R.2    Goetz, D.D.3
  • 11
    • 0031788080 scopus 로고    scopus 로고
    • Relationship of femoral head and acetabular size to the prevalence of dislocation
    • Kelley S.S., Lachiewicz P.F., Hickman J.M., et al. Relationship of femoral head and acetabular size to the prevalence of dislocation. Clin Orthop 355 (1998) 163
    • (1998) Clin Orthop , vol.355 , pp. 163
    • Kelley, S.S.1    Lachiewicz, P.F.2    Hickman, J.M.3
  • 12
    • 1842578591 scopus 로고    scopus 로고
    • Short-term in vivo wear of cross-linked polyethylene
    • Heisel C., Silva M., dela Rosa M.A., et al. Short-term in vivo wear of cross-linked polyethylene. J Bone Joint Surg Am 86 (2004) 748
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 748
    • Heisel, C.1    Silva, M.2    dela Rosa, M.A.3
  • 13
    • 0022442544 scopus 로고
    • Revision of failed hip surface replacement arthroplasties with a bipolar prosthesis
    • McClelland S.J., Godfrey J.D., Benton P.C., et al. Revision of failed hip surface replacement arthroplasties with a bipolar prosthesis. Clin Orthop 208 (1986) 243
    • (1986) Clin Orthop , vol.208 , pp. 243
    • McClelland, S.J.1    Godfrey, J.D.2    Benton, P.C.3
  • 14
    • 0026605273 scopus 로고
    • Bipolar hip arthroplasty for recurrent dislocation after total hip arthroplasty: a report of three cases
    • Ries M.D., and Wiedel J.D. Bipolar hip arthroplasty for recurrent dislocation after total hip arthroplasty: a report of three cases. Clin Orthop 278 (1992) 121
    • (1992) Clin Orthop , vol.278 , pp. 121
    • Ries, M.D.1    Wiedel, J.D.2
  • 15
    • 0028206497 scopus 로고
    • Tripolar hip replacement for recurrent prosthetic dislocation
    • Grigoris P., Grecula M.J., and Amstutz H.C. Tripolar hip replacement for recurrent prosthetic dislocation. Clin Orthop 304 (1994) 148
    • (1994) Clin Orthop , vol.304 , pp. 148
    • Grigoris, P.1    Grecula, M.J.2    Amstutz, H.C.3
  • 16
    • 0036484326 scopus 로고    scopus 로고
    • Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement
    • Beaule P.E., Schmalzried T.P., Udomkiat P., et al. Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement. J Bone Joint Surg Am 84 (2002) 256
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 256
    • Beaule, P.E.1    Schmalzried, T.P.2    Udomkiat, P.3
  • 17
    • 9644279454 scopus 로고    scopus 로고
    • Prevention and treatment of dislocation after total hip replacement using large diameter balls
    • Amstutz H.C., Le Duff M.J., and Beaule P.E. Prevention and treatment of dislocation after total hip replacement using large diameter balls. Clin Orthop 429 (2004) 108
    • (2004) Clin Orthop , vol.429 , pp. 108
    • Amstutz, H.C.1    Le Duff, M.J.2    Beaule, P.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.