메뉴 건너뛰기




Volumn 59, Issue 6, 2006, Pages 666-667

Therapeutic drug monitoring of vancomycin in patients receiving haemodialysis: Time for a change [4]

Author keywords

[No Author keywords available]

Indexed keywords

POLYCLONAL ANTIBODY; VANCOMYCIN;

EID: 33745069632     PISSN: 00219746     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Letter
Times cited : (1)

References (5)
  • 1
    • 0030039451 scopus 로고    scopus 로고
    • Falsely elevated serum vancomycin concentrations in hemodialysis patients
    • Follin SL, Mueller BA, Scott MK, et al. Falsely elevated serum vancomycin concentrations in hemodialysis patients. Am J Kidney Dis 1996;27:67-74.
    • (1996) Am J Kidney Dis , vol.27 , pp. 67-74
    • Follin, S.L.1    Mueller, B.A.2    Scott, M.K.3
  • 2
    • 0033031933 scopus 로고    scopus 로고
    • Implications of vancomycin degradation products on therapeutic drug monitoring in patients with end-stage renal disease
    • Somerville AL, Wright DH, Rotschofer JC. Implications of vancomycin degradation products on therapeutic drug monitoring in patients with end-stage renal disease. Pharmacotherapy 1999;19:702-7.
    • (1999) Pharmacotherapy , vol.19 , pp. 702-707
    • Somerville, A.L.1    Wright, D.H.2    Rotschofer, J.C.3
  • 3
    • 0038262684 scopus 로고    scopus 로고
    • Evaluation of commercial assays for vancomycin and aminoglycosides in serum: A comparison of accuracy and precision based on external quality assessment
    • Wilson JF, Davis AC, Tobin CM. Evaluation of commercial assays for vancomycin and aminoglycosides in serum: a comparison of accuracy and precision based on external quality assessment. J Antimicrob Chemother 2003;52:78-82.
    • (2003) J Antimicrob Chemother , vol.52 , pp. 78-82
    • Wilson, J.F.1    Davis, A.C.2    Tobin, C.M.3
  • 4
    • 0031980142 scopus 로고    scopus 로고
    • New modified fluorescence polarization immunoassay does not falsely elevate vancomycin concentrations in patients with end-stage renal disease
    • Smith PF, Petros WP, Soucie MP, et al. New modified fluorescence polarization immunoassay does not falsely elevate vancomycin concentrations in patients with end-stage renal disease. Ther Drug Monit 1998;20:231-5.
    • (1998) Ther Drug Monit , vol.20 , pp. 231-235
    • Smith, P.F.1    Petros, W.P.2    Soucie, M.P.3
  • 5
    • 0036848114 scopus 로고    scopus 로고
    • Vancomycin therapeutic drug monitoring: Is there a consensus view? The results of a UK National External Quality Assessment Scheme (UK NEQAS) for Antibiotic Assays Questionnaire
    • Tobin CM, Darville JM, Thomson AH, et al. Vancomycin therapeutic drug monitoring: is there a consensus view? The results of a UK National External Quality Assessment Scheme (UK NEQAS) for Antibiotic Assays Questionnaire. J Antimicrob Chemother 2002;50:713-8.
    • (2002) J Antimicrob Chemother , vol.50 , pp. 713-718
    • Tobin, C.M.1    Darville, J.M.2    Thomson, A.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.