메뉴 건너뛰기




Volumn 28, Issue 5, 2006, Pages 136-141

Developing PEEK polymer as a bearing material for implants

Author keywords

[No Author keywords available]

Indexed keywords


EID: 33745058118     PISSN: 0194844X     EISSN: None     Source Type: Trade Journal    
DOI: None     Document Type: Conference Paper
Times cited : (5)

References (14)
  • 2
    • 0029882821 scopus 로고    scopus 로고
    • Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces
    • TP Schmalzreid et al., "Long-Duration Metal-on-Metal Total Hip Arthroplasties with Low Wear of the Articulating Surfaces," Journal of Arthroplasty 11, no. 3 (1996): 322-331.
    • (1996) Journal of Arthroplasty , vol.11 , Issue.3 , pp. 322-331
    • Schmalzreid, T.P.1
  • 3
    • 0036380582 scopus 로고    scopus 로고
    • Ion release in patients with metal-on-metal hip bearings in total joint replacement: A comparison with Metal-on-polyethylene bearings
    • L Savarino et al., "Ion Release in Patients with Metal-on-Metal Hip Bearings in Total Joint Replacement: A Comparison with Metal-on-Polyethylene Bearings," Journal of Biomedical Materials Research 63, no. 5 (2002): 467-474.
    • (2002) Journal of Biomedical Materials Research , vol.63 , Issue.5 , pp. 467-474
    • Savarino, L.1
  • 4
    • 0033178826 scopus 로고    scopus 로고
    • Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)
    • OK Muratoglu et al., "Unified Wear Model for Highly Crosslinked Ultra-High Molecular Weight Polyethylenes (UHMWPE)," Biomaterials 20, no. 16 (1999): 1463-1470.
    • (1999) Biomaterials , vol.20 , Issue.16 , pp. 1463-1470
    • Muratoglu, O.K.1
  • 5
    • 0033492096 scopus 로고    scopus 로고
    • Suitability and limitations of carbon fiber reinforced PEEK composites as bearing surfaces for total joint replacement
    • Wang et al., "Suitability and Limitations of Carbon Fiber Reinforced PEEK Composites as Bearing Surfaces for Total Joint Replacement," Wear 225-229 (1999): 724-727.
    • (1999) Wear , vol.225-229 , pp. 724-727
    • Wang1
  • 6
    • 33745081352 scopus 로고    scopus 로고
    • Long-term wear behaviour of a flexible, anatomically loaded hip cup design
    • paper presented Singapore, December 7-10
    • A Unsworth and SC Scholes, "Long-Term Wear Behaviour of a Flexible, Anatomically Loaded Hip Cup Design" (paper presented at the 12th International Conference on Biomedical Engineering, Singapore, December 7-10, 2005).
    • (2005) 12th International Conference on Biomedical Engineering
    • Unsworth, A.1    Scholes, S.C.2
  • 7
    • 34247614543 scopus 로고    scopus 로고
    • Clinical trial of a new CF-PEEK acetabular insert in hip arthroplasty
    • Baveno, Italy: European Hip Society
    • N Pace et al., "Clinical Trial of a New CF-PEEK Acetabular Insert in Hip Arthroplasty," in Abstracts from the European Hip Society 2002 Domestic Meeting (Baveno, Italy: European Hip Society), 212.
    • Abstracts from the European Hip Society 2002 Domestic Meeting , pp. 212
    • Pace, N.1
  • 8
    • 84945626113 scopus 로고
    • Effect of quenching and annealing on fiber pull out from crystalline polymer matrices
    • H Kobayashi et al., "Effect of Quenching and Annealing on Fiber Pull Out from Crystalline Polymer Matrices," Advanced Composite Materials 1, no. 2 (1991): 155-168.
    • (1991) Advanced Composite Materials , vol.1 , Issue.2 , pp. 155-168
    • Kobayashi, H.1
  • 12
    • 0031205776 scopus 로고    scopus 로고
    • Why the fibre/polymer interface can appear to be stronger than the polymer matrix
    • MR Piggott, "Why the Fibre/Polymer Interface Can Appear to Be Stronger than the Polymer Matrix," Composites Science and Technology 57, no. 8 (1997): 853-857.
    • (1997) Composites Science and Technology , vol.57 , Issue.8 , pp. 853-857
    • Piggott, M.R.1
  • 13
    • 0027486304 scopus 로고
    • Evaluation of wear in an all-polymer total knee replacement. Part 1: Laboratory testing of polyethylene on polyacetal bearing surfaces
    • McKellop et al., "Evaluation of Wear in an All-Polymer Total Knee Replacement. Part 1: Laboratory Testing of Polyethylene on Polyacetal Bearing Surfaces," Clinical Materials 14, no. 2 (1993): 117-126.
    • (1993) Clinical Materials , vol.14 , Issue.2 , pp. 117-126
    • McKellop1
  • 14
    • 33745077804 scopus 로고    scopus 로고
    • Reduced articular cartilage wear using an elastomer compared to a CoCr femoral head in canine hemiarthroplasty
    • paper presented Society for Biomaterials, Memphis, April 27-30
    • TM Turner, "Reduced Articular Cartilage Wear Using an Elastomer Compared to a CoCr Femoral Head in Canine Hemiarthroplasty" (paper presented at the 30th Annual Meeting, Society for Biomaterials, Memphis, April 27-30, 2005).
    • (2005) 30th Annual Meeting
    • Turner, T.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.