메뉴 건너뛰기




Volumn 79, Issue 2, 2006, Pages 203-207

Does 4 MV perform better compared to 6 MV in the presence of air cavities in the head and neck region?

Author keywords

4 versus 6 MV X ray irradiation; Air cavity effects; Electronic equilibrium; Larynx and maxillary sinus; Tissue inhomogeneity

Indexed keywords

POLYSTYRENE;

EID: 33745002959     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2006.04.002     Document Type: Article
Times cited : (6)

References (16)
  • 1
    • 0023144768 scopus 로고
    • A comparison of air-cavity inhomogoneity effects for cobalt-60, 6-, and 10-MV x-ray beams
    • Beach J.L., Mendiondo M.S., and Mendiondo O.A. A comparison of air-cavity inhomogoneity effects for cobalt-60, 6-, and 10-MV x-ray beams. Med Phys 14 (1987) 140-144
    • (1987) Med Phys , vol.14 , pp. 140-144
    • Beach, J.L.1    Mendiondo, M.S.2    Mendiondo, O.A.3
  • 2
    • 0032708803 scopus 로고    scopus 로고
    • Diamond detector measurements near simulated air channels for narrow photon beams
    • De Vlamynck K., De Wagter C., and De Neve W. Diamond detector measurements near simulated air channels for narrow photon beams. Radiother Oncol 53 (1999) 155-159
    • (1999) Radiother Oncol , vol.53 , pp. 155-159
    • De Vlamynck, K.1    De Wagter, C.2    De Neve, W.3
  • 3
    • 0000689197 scopus 로고
    • Ionization build-up in upper respiratory air cavities during teletherapy with cobalt 60 radiation
    • Epp E.R., Lougheed M.N., and McKay J.W. Ionization build-up in upper respiratory air cavities during teletherapy with cobalt 60 radiation. Br J Radiol 31 (1958) 361-367
    • (1958) Br J Radiol , vol.31 , pp. 361-367
    • Epp, E.R.1    Lougheed, M.N.2    McKay, J.W.3
  • 4
    • 0017659613 scopus 로고
    • Underdosing of lesions resulting from lack of electronic equilibrium in upper respiratory air cavities irradiated by 10 MV x-ray beams
    • Epp E.R., Boyer A.L., and Doppke K.P. Underdosing of lesions resulting from lack of electronic equilibrium in upper respiratory air cavities irradiated by 10 MV x-ray beams. Int J Radiat Oncol Biol Phys 2 (1977) 613-619
    • (1977) Int J Radiat Oncol Biol Phys , vol.2 , pp. 613-619
    • Epp, E.R.1    Boyer, A.L.2    Doppke, K.P.3
  • 5
    • 0029870694 scopus 로고    scopus 로고
    • Do overall treatment time, field size, and treatment energy influence local control of T1-T2 squamous cell carcinomas of the glottic larynx?
    • Fein D.A., Lee W.R., Hanlon A.L., et al. Do overall treatment time, field size, and treatment energy influence local control of T1-T2 squamous cell carcinomas of the glottic larynx?. Int J Radiat Oncol Biol Phys 34 (1996) 823-831
    • (1996) Int J Radiat Oncol Biol Phys , vol.34 , pp. 823-831
    • Fein, D.A.1    Lee, W.R.2    Hanlon, A.L.3
  • 6
    • 0026717507 scopus 로고
    • Early-Stage squamous cell carcinoma of the glottic larynx managed with radiation therapy
    • Foote R.L., Kerry D.O., Kunselman S.J., et al. Early-Stage squamous cell carcinoma of the glottic larynx managed with radiation therapy. Mayo Clin Proc 67 (1992) 629-636
    • (1992) Mayo Clin Proc , vol.67 , pp. 629-636
    • Foote, R.L.1    Kerry, D.O.2    Kunselman, S.J.3
  • 7
    • 0025159607 scopus 로고
    • Treatment of early vocal cord carcinoma with 60Co gamma rays, 8/10 MV x-rays, or 4 MV x-rays-are the results different?
    • Izuno I., Sone S., Oguchi M., et al. Treatment of early vocal cord carcinoma with 60Co gamma rays, 8/10 MV x-rays, or 4 MV x-rays-are the results different?. Acta Oncol 29 (1990) 637-639
    • (1990) Acta Oncol , vol.29 , pp. 637-639
    • Izuno, I.1    Sone, S.2    Oguchi, M.3
  • 8
    • 0031929807 scopus 로고    scopus 로고
    • The effect of the nasopharyngeal air cavity on x-ray interface doses
    • Kan W.K., Wu P.M., Leung H.T., et al. The effect of the nasopharyngeal air cavity on x-ray interface doses. Phys Med Biol 43 (1998) 529-537
    • (1998) Phys Med Biol , vol.43 , pp. 529-537
    • Kan, W.K.1    Wu, P.M.2    Leung, H.T.3
  • 10
    • 33744986898 scopus 로고    scopus 로고
    • NCS Report 2. Code of practice for the dosimetry of high-energy photon beams. 1986.
  • 12
    • 3242781030 scopus 로고    scopus 로고
    • An accurate calibration method of the multileaf collimator valid for conformal and intensity modulated radiation
    • Sastre-Padro M., Heide van der U.A., and Welleweerd H. An accurate calibration method of the multileaf collimator valid for conformal and intensity modulated radiation. Phys Med Biol 49 (2004) 2631-2643
    • (2004) Phys Med Biol , vol.49 , pp. 2631-2643
    • Sastre-Padro, M.1    Heide van der, U.A.2    Welleweerd, H.3
  • 13
    • 0028897629 scopus 로고
    • Implications of tissue heterogeneity for radiosurgery in head and neck tumors
    • Solberg T.D., Holly F.E., De Salles A.A.F., et al. Implications of tissue heterogeneity for radiosurgery in head and neck tumors. Int J Radiat Oncol Biol Phys 32 (1995) 235-239
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 235-239
    • Solberg, T.D.1    Holly, F.E.2    De Salles, A.A.F.3
  • 15
    • 33644746295 scopus 로고    scopus 로고
    • Spirydovich S, Papieza L, Moskvin V, Desrosiers P. Evaluation of underdosage in the external photon beam radiotherapy of glottic carcinoma: monte carlo study. Radiother Oncol 2006;78:159-64.
  • 16
    • 0035424090 scopus 로고    scopus 로고
    • Monte Carlo evaluation of tissue inhomogeneity effects in the treatment of the head and neck
    • Wang L., Yorke E., and Chui C.S. Monte Carlo evaluation of tissue inhomogeneity effects in the treatment of the head and neck. Int J Radiat Oncol Biol Phys 50 (2001) 1339-1349
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 1339-1349
    • Wang, L.1    Yorke, E.2    Chui, C.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.