-
1
-
-
0035166734
-
Radioguidance for nonpalpable primary lesions and sentinel lymph node(s)
-
Gray R.J., Giuliano R., Dauway E.L., et al. Radioguidance for nonpalpable primary lesions and sentinel lymph node(s). Am J Surg 182 (2001) 404-406
-
(2001)
Am J Surg
, vol.182
, pp. 404-406
-
-
Gray, R.J.1
Giuliano, R.2
Dauway, E.L.3
-
2
-
-
0034785427
-
Randomized prospective evaluation of a novel technique for biopsy or lumpectomy of nonpalpable breast lesions. radioactive seed versus wire localization
-
Gray R.J., Salud C., Nguyen K., et al. Randomized prospective evaluation of a novel technique for biopsy or lumpectomy of nonpalpable breast lesions. radioactive seed versus wire localization. Ann Surg Oncol 8 (2001) 711-715
-
(2001)
Ann Surg Oncol
, vol.8
, pp. 711-715
-
-
Gray, R.J.1
Salud, C.2
Nguyen, K.3
-
3
-
-
0020955166
-
Transection of the localization hooked wire during breast biopsy
-
Homer M.J. Transection of the localization hooked wire during breast biopsy. AJR Am J Roentgenol 141 (1983) 929-930
-
(1983)
AJR Am J Roentgenol
, vol.141
, pp. 929-930
-
-
Homer, M.J.1
-
4
-
-
0006323686
-
Innovative diagnostics for breast cancer. new frontiers for the new millennium using radioactive seed localization
-
Dauway E.L., Sanders R., Friedland J., et al. Innovative diagnostics for breast cancer. new frontiers for the new millennium using radioactive seed localization. Surg Forum 50 (1999) 348-349
-
(1999)
Surg Forum
, vol.50
, pp. 348-349
-
-
Dauway, E.L.1
Sanders, R.2
Friedland, J.3
-
5
-
-
4944227176
-
Radioactive seed localization of nonpalpable breast lesions is better than wire localization
-
Gray R.J., Pockaj B.A., Karstaedt P.J., et al. Radioactive seed localization of nonpalpable breast lesions is better than wire localization. Am J Surg 188 (2004) 377-380
-
(2004)
Am J Surg
, vol.188
, pp. 377-380
-
-
Gray, R.J.1
Pockaj, B.A.2
Karstaedt, P.J.3
-
6
-
-
33745010321
-
-
[abstract]. Presented at the Radiological Society of North America 90th Scientific Assembly and Annual Meeting, Chicago, Ill: November 28-December 3
-
Karstaedt P., Gray R., Patel M., et al. Radioactive seed localization of non-palpable breast lesions. a preferred alternative to wire localization (2004) [abstract]. Presented at the Radiological Society of North America 90th Scientific Assembly and Annual Meeting, Chicago, Ill: November 28-December 3
-
(2004)
Radioactive seed localization of non-palpable breast lesions. a preferred alternative to wire localization
-
-
Karstaedt, P.1
Gray, R.2
Patel, M.3
-
7
-
-
33745009850
-
-
Release of individuals containing unsealed byproduct material or implants containing byproduct material (10 CFR 35.75). Washington, DC: US Nuclear Regulatory Commission [revised 2005 May 27; cited 2006 Mar 22]. Available from: http://www.nrc.gov/reading-rm/doc-collections/cfr/part035/part035-0075.html.
-
-
-
-
9
-
-
1142304255
-
Update of AAPM Task Group No. 43 report. a revised AAPM protocol for brachytherapy dose calculations
-
Erratum in: Med Phys 2004; 31:3532-3533
-
Rivard M.J., Coursey B.M., DeWerd L.A., et al. Update of AAPM Task Group No. 43 report. a revised AAPM protocol for brachytherapy dose calculations. Med Phys 31 (2004) 633-674 Erratum in: Med Phys 2004; 31:3532-3533
-
(2004)
Med Phys
, vol.31
, pp. 633-674
-
-
Rivard, M.J.1
Coursey, B.M.2
DeWerd, L.A.3
-
10
-
-
0035051575
-
Comparison of I-125 sources used for permanent interstitial implants
-
Heintz B.H., Wallace R.E., and Hevezi J.M. Comparison of I-125 sources used for permanent interstitial implants. Med Phys 28 (2001) 671-682
-
(2001)
Med Phys
, vol.28
, pp. 671-682
-
-
Heintz, B.H.1
Wallace, R.E.2
Hevezi, J.M.3
|