Volumn 38, Issue 1, 2006, Pages 22-26

Evaluation of biocompatible cardiopulmonary bypass circuit use during pediatric open heart surgery

Author keywords

2 methoxyethylacrylate; Biocompatible circuits; Congenital heart surgery; Immune response; Pediatric cardiopulmonary bypass

Indexed keywords

ACRYLIC ACID DERIVATIVE; POLY(2 METHOXYETHYLACRYLIC ACID); UNCLASSIFIED DRUG; BIOMATERIAL; POLY(2 METHOXYETHYLACRYLATE); POLY(2-METHOXYETHYLACRYLATE); POLYMER;

EID: 33744980219     PISSN: 00221058     EISSN: 29698960     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (20)
  • 2
    • 0027280189 scopus 로고
    • Complement activation during extracorporeal circulation. In vitro comparison of Duraflo II heparin-coated and uncoated oxygenator
    • Svennevig JL, Geiran OR, Karsen H, et al. Complement activation during extracorporeal circulation. In vitro comparison of Duraflo II heparin-coated and uncoated oxygenator. J Thorac Cardiovasc Surg. 1993;106:466-72.
    • (1993) J Thorac Cardiovasc Surg , vol.106 , pp. 466-472
    • Svennevig, J.L.1    Geiran, O.R.2    Karsen, H.3
  • 3
    • 0027159961 scopus 로고
    • Blood-surface interactions during cardiopulmonary bypass
    • Edmunds LH. Blood-surface interactions during cardiopulmonary bypass. J Card Surg. 1993;8:404-10.
    • (1993) J Card Surg , vol.8 , pp. 404-410
    • Edmunds, L.H.1
  • 4
    • 0029842440 scopus 로고    scopus 로고
    • Leukocyte depletion in cardiothoracic surgery
    • Allen SM. Leukocyte depletion in cardiothoracic surgery. Perfusion. 1996;11:270-7.
    • (1996) Perfusion , vol.11 , pp. 270-277
    • Allen, S.M.1
  • 5
    • 0029983976 scopus 로고    scopus 로고
    • Aprotinin reduces interleukin-8 production and lung neutrophil accumulation after cardiopulmonary bypass
    • Hill GE, Pohorecki R, Alonso A, Rennard SI, Robbins RA. Aprotinin reduces interleukin-8 production and lung neutrophil accumulation after cardiopulmonary bypass. Anesth Analg. 1996;83:696-700.
    • (1996) Anesth Analg , vol.83 , pp. 696-700
    • Hill, G.E.1    Pohorecki, R.2    Alonso, A.3    Rennard, S.I.4    Robbins, R.A.5
  • 6
    • 0028972012 scopus 로고
    • Aprotinin and methylprednisolone equally blunt cardiopulmonary bypass-induced inflammation in humans
    • Hill GE, Alonso A, Spurzem RJR, Stammers AH, Robbins RA. Aprotinin and methylprednisolone equally blunt cardiopulmonary bypass-induced inflammation in humans. J Thorac Cardiovasc Surg. 1995;110:1658-62.
    • (1995) J Thorac Cardiovasc Surg , vol.110 , pp. 1658-1662
    • Hill, G.E.1    Alonso, A.2    Spurzem, R.J.R.3    Stammers, A.H.4    Robbins, R.A.5
  • 7
    • 0029610564 scopus 로고
    • Hemostatic mechanism associated with aprotinin during and after extracorporeal circulation for cardiac and great vessel surgery
    • Takaori M, Fukui A, Kimura K, et al. Hemostatic mechanism associated with aprotinin during and after extracorporeal circulation for cardiac and great vessel surgery. Masui. 1995;44:1661-6.
    • (1995) Masui , vol.44 , pp. 1661-1666
    • Takaori, M.1    Fukui, A.2    Kimura, K.3
  • 8
    • 0025227931 scopus 로고
    • Bleeding complications associated with cardiopulmonary bypass
    • Woodman RC, Harker LA. Bleeding complications associated with cardiopulmonary bypass. Blood. 1990;76:1680-7.
    • (1990) Blood , vol.76 , pp. 1680-1687
    • Woodman, R.C.1    Harker, L.A.2
  • 9
    • 0028965954 scopus 로고
    • One month follow-up of haemostatic variables in patients undergoing aortocoronary bypass surgery. Effect of aprotinin
    • Mannucci L, Gerometta PS, Mussoni L, et al. One month follow-up of haemostatic variables in patients undergoing aortocoronary bypass surgery. Effect of aprotinin. Thromb Haemost. 1995;73:356-61.
    • (1995) Thromb Haemost , vol.73 , pp. 356-361
    • Mannucci, L.1    Gerometta, P.S.2    Mussoni, L.3
  • 10
  • 11
    • 0030027445 scopus 로고    scopus 로고
    • Initiation of white cell activation during cardiopulmonary bypass: Cytokines and receptors
    • Cameron D. Initiation of white cell activation during cardiopulmonary bypass: Cytokines and receptors. J Cardiovasc Pharmacol. 1996;27(suppl 1):S1-5.
    • (1996) J Cardiovasc Pharmacol , vol.27 , Issue.SUPPL. 1
    • Cameron, D.1
  • 12
    • 0035007741 scopus 로고    scopus 로고
    • Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model
    • Suhara H, Sawa Y, Nishimura M, et al. Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model. Ann Thorac Surg. 2001;71:1602-8.
    • (2001) Ann Thorac Surg , vol.71 , pp. 1602-1608
    • Suhara, H.1    Sawa, Y.2    Nishimura, M.3
  • 13
    • 2442704368 scopus 로고    scopus 로고
    • The impact of heparin-coated cardiopulmonary bypass circuits on pulmonary function and the release of inflammatory mediators
    • de Vroege R, van Oeveren W, van Klarenbosch J, et al. The impact of heparin-coated cardiopulmonary bypass circuits on pulmonary function and the release of inflammatory mediators. Anesth Analg. 2004;98:1586-94.
    • (2004) Anesth Analg , vol.98 , pp. 1586-1594
    • de Vroege, R.1    van Oeveren, W.2    van Klarenbosch, J.3
  • 14
  • 15
    • 0942298780 scopus 로고    scopus 로고
    • The effects of heparin coated circuits on pulmonary injury. A clinical study
    • Kazaz H, Oto O, Sariosmanoglu N, Hazan E. The effects of heparin coated circuits on pulmonary injury. A clinical study. J Cardiovasc Surg (Torino). 2003;44:611-5.
    • (2003) J Cardiovasc Surg (Torino) , vol.44 , pp. 611-615
    • Kazaz, H.1    Oto, O.2    Sariosmanoglu, N.3    Hazan, E.4
  • 16
    • 1942436754 scopus 로고    scopus 로고
    • A new poly-2-methoxyethylacrylate- coated cardiopulmonary bypass circuit possesses superior platelet preservation and inflammatory suppression efficacy
    • Ikuta T, Fujii H, Shibata T, et al. A new poly-2-methoxyethylacrylate- coated cardiopulmonary bypass circuit possesses superior platelet preservation and inflammatory suppression efficacy. Ann Thorac Surg. 2004;77:1678-83.
    • (2004) Ann Thorac Surg , vol.77 , pp. 1678-1683
    • Ikuta, T.1    Fujii, H.2    Shibata, T.3
  • 17
    • 0036712911 scopus 로고    scopus 로고
    • Clinical performance and biocompatibility of poly (2-methoxyethylacrylate)- coated extracorporeal circuits
    • Gunaydin S, Farsak B, Kocakulak M, Sari T, Yorgancioglu C, Zorlutuna Y. Clinical performance and biocompatibility of poly (2-methoxyethylacrylate)- coated extracorporeal circuits. Ann Thorac Surg. 2002;74:819-24.
    • (2002) Ann Thorac Surg , vol.74 , pp. 819-824
    • Gunaydin, S.1    Farsak, B.2    Kocakulak, M.3    Sari, T.4    Yorgancioglu, C.5    Zorlutuna, Y.6
  • 18
    • 0038204335 scopus 로고    scopus 로고
    • Biocompatibility of poly2methoxyethylacrylate coating for cardiopulmonary bypass
    • Noguchi M, Eishi K, Tada S, et al. Biocompatibility of poly2methoxyethylacrylate coating for cardiopulmonary bypass. Ann Thorac Cardiovasc Surg. 2003;9:22-8.
    • (2003) Ann Thorac Cardiovasc Surg , vol.9 , pp. 22-28
    • Noguchi, M.1    Eishi, K.2    Tada, S.3
  • 19
    • 0037335069 scopus 로고    scopus 로고
    • Influence of PMEA-coated bypass circuits on perioperative inflammatory response
    • Ninomiya M, Miyaji K, Takamoto S. Influence of PMEA-coated bypass circuits on perioperative inflammatory response. Ann Thorac Surg. 2003;75:913-7.
    • (2003) Ann Thorac Surg , vol.75 , pp. 913-917
    • Ninomiya, M.1    Miyaji, K.2    Takamoto, S.3
  • 20
    • 2442466089 scopus 로고    scopus 로고
    • Hemocompatibility of PMEA coated oxygenators used for extracorporeal circulation procedures
    • Zimmermann AK, Aebert H, Reiz A, et al. Hemocompatibility of PMEA coated oxygenators used for extracorporeal circulation procedures. ASAIO J. 2004;50:193-9.
    • (2004) ASAIO J , vol.50 , pp. 193-199
    • Zimmermann, A.K.1    Aebert, H.2    Reiz, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.