-
1
-
-
0002699921
-
Metal selection and surface characteristics
-
Brånemark P.-I., Zrab G.A., and Albrektsson T. (Eds), Quintessence, Chicago
-
Kasemo B., and Lausmaa J. Metal selection and surface characteristics. In: Brånemark P.-I., Zrab G.A., and Albrektsson T. (Eds). Tissue-integrated prostheses (1985), Quintessence, Chicago 99-116
-
(1985)
Tissue-integrated prostheses
, pp. 99-116
-
-
Kasemo, B.1
Lausmaa, J.2
-
2
-
-
0042793632
-
Dimensional change in wax patterns during setting of gypsum investments
-
Mumford G., and Phillips R.W. Dimensional change in wax patterns during setting of gypsum investments. J Dent Res 37 (1958) 351-358
-
(1958)
J Dent Res
, vol.37
, pp. 351-358
-
-
Mumford, G.1
Phillips, R.W.2
-
3
-
-
0041791449
-
The influence of various factors on the effective setting expansion of casting investments
-
Mahler D.B., and Ady A.B. The influence of various factors on the effective setting expansion of casting investments. J Prosthet Dent 13 (1963) 365-373
-
(1963)
J Prosthet Dent
, vol.13
, pp. 365-373
-
-
Mahler, D.B.1
Ady, A.B.2
-
4
-
-
0023394411
-
Limiting wax pattern distortion caused by setting expansion
-
Davis D.R. Limiting wax pattern distortion caused by setting expansion. J Prosthet Dent 58 (1987) 229-234
-
(1987)
J Prosthet Dent
, vol.58
, pp. 229-234
-
-
Davis, D.R.1
-
5
-
-
0028038247
-
Accuracy of titanium cast crowns obtained from calcia base mold
-
Takahashi H., Miyazaki T., and Kawawa T. Accuracy of titanium cast crowns obtained from calcia base mold. Clin Mater 16 (1994) 155-160
-
(1994)
Clin Mater
, vol.16
, pp. 155-160
-
-
Takahashi, H.1
Miyazaki, T.2
Kawawa, T.3
-
6
-
-
2942592813
-
Thermal expansion typed investments for casting titanium
-
Kitahara K., Kubo F., and Takahashi J. Thermal expansion typed investments for casting titanium. Dent Mater J 23 1 (2004) 1-7
-
(2004)
Dent Mater J
, vol.23
, Issue.1
, pp. 1-7
-
-
Kitahara, K.1
Kubo, F.2
Takahashi, J.3
-
7
-
-
0028711948
-
The effect of investment type on the fit of cast titanium crowns
-
Mori T., Jean-Louis M., Yabugami M., and Togaya T. The effect of investment type on the fit of cast titanium crowns. Aust Dent J 39 6 (1994) 348-352
-
(1994)
Aust Dent J
, vol.39
, Issue.6
, pp. 348-352
-
-
Mori, T.1
Jean-Louis, M.2
Yabugami, M.3
Togaya, T.4
-
8
-
-
1542692029
-
Application of yttria investment to dental casting of titanium.
-
p. 269
-
Tamaki Y., Miyazaki T., Hotta Y., Ogawa H., Suzuki E., and Miyaji T. Application of yttria investment to dental casting of titanium. Transactions of international congress on dental materials, USA; November (1989) p. 269
-
(1989)
Transactions of international congress on dental materials, USA; November
-
-
Tamaki, Y.1
Miyazaki, T.2
Hotta, Y.3
Ogawa, H.4
Suzuki, E.5
Miyaji, T.6
-
11
-
-
0029294810
-
Use of CAD/CAM system to fabricate dental prostheses. Part 1. CAD for a clinical crown restoration
-
Sohmura T., and Takahashi J. Use of CAD/CAM system to fabricate dental prostheses. Part 1. CAD for a clinical crown restoration. Int J Prodthodont 8 (1995) 252-258
-
(1995)
Int J Prodthodont
, vol.8
, pp. 252-258
-
-
Sohmura, T.1
Takahashi, J.2
-
12
-
-
4344565114
-
Durability of tungsten carbide burs for the fabrication of titanium crowns using dental CAD/CAM
-
Hotta Y., Miyazaki T., Fujiwara T., Tomita S., Shinya A., Sugai Y., et al. Durability of tungsten carbide burs for the fabrication of titanium crowns using dental CAD/CAM. Dent Mater J 23 (2004) 190-196
-
(2004)
Dent Mater J
, vol.23
, pp. 190-196
-
-
Hotta, Y.1
Miyazaki, T.2
Fujiwara, T.3
Tomita, S.4
Shinya, A.5
Sugai, Y.6
-
13
-
-
33744925706
-
Waxing-up basic techniques
-
[extra issue/waxing up], (in Japanese)
-
Tsutihira K., and Ishiwata M. Waxing-up basic techniques. J Dent Technol (2003) 83 [extra issue/waxing up], (in Japanese)
-
(2003)
J Dent Technol
, pp. 83
-
-
Tsutihira, K.1
Ishiwata, M.2
-
14
-
-
12444268491
-
Properties of an aluminous cement-bonded MgO-based investment (Selevest)
-
p. 186
-
Ohyagi S., Iwaki S., Shimakawa S., Nakai F., and Togaya T. Properties of an aluminous cement-bonded MgO-based investment (Selevest). Proceedings of the third international symposium on titanium in dentistry, Australia; August (1995) p. 186
-
(1995)
Proceedings of the third international symposium on titanium in dentistry, Australia; August
-
-
Ohyagi, S.1
Iwaki, S.2
Shimakawa, S.3
Nakai, F.4
Togaya, T.5
-
16
-
-
33744943825
-
-
ISO 9694. Dental phosphate-bonded investments; 1996.
-
-
-
-
17
-
-
4644297571
-
Pure titanium casting into zirconia-modified magnesia-based investment molds
-
Hung C.C., Hou G.L., Tsai C.C., and Huang C.C. Pure titanium casting into zirconia-modified magnesia-based investment molds. Dent Mater 20 (2004) 846-851
-
(2004)
Dent Mater
, vol.20
, pp. 846-851
-
-
Hung, C.C.1
Hou, G.L.2
Tsai, C.C.3
Huang, C.C.4
-
18
-
-
0033130665
-
Titanium full crown casting: thermal expansion of investments and crown accuracy
-
Low D., and Mori T. Titanium full crown casting: thermal expansion of investments and crown accuracy. Dent Mater 15 (1999) 185-190
-
(1999)
Dent Mater
, vol.15
, pp. 185-190
-
-
Low, D.1
Mori, T.2
|