메뉴 건너뛰기




Volumn 39, Issue 3, 2006, Pages 253-258

Simulation of anteroseptal myocardial infarction by electrocardiographic filters

Author keywords

Acute myocardial infarction; Artifacts; Electrocardiography; Filters

Indexed keywords

ADULT; ARTICLE; ARTIFACT; BREATHING; CONTROLLED STUDY; ELECTROCARDIOGRAPHY; FEMALE; FILTER; HEART INFARCTION; HUMAN; HUMAN EXPERIMENT; MALE; NORMAL HUMAN; PRIORITY JOURNAL; SIMULATION; ST SEGMENT; ST SEGMENT DEPRESSION; ST SEGMENT ELEVATION; STATISTICAL ANALYSIS;

EID: 33744901150     PISSN: 00220736     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jelectrocard.2005.11.001     Document Type: Article
Times cited : (16)

References (11)
  • 1
    • 0023182059 scopus 로고
    • Clinically significant differences between the "old" analog and the "new" digital electrocardiograms
    • Garson Jr. A. Clinically significant differences between the "old" analog and the "new" digital electrocardiograms. Am Heart J 114 1 Pt 1 (1987) 194
    • (1987) Am Heart J , vol.114 , Issue.1 PART 1 , pp. 194
    • Garson Jr., A.1
  • 2
    • 84859614476 scopus 로고
    • Some instrument-induced errors in the electrocardiogram
    • Meyer J.L. Some instrument-induced errors in the electrocardiogram. JAMA 201 6 (1967) 91
    • (1967) JAMA , vol.201 , Issue.6 , pp. 91
    • Meyer, J.L.1
  • 3
    • 0013920022 scopus 로고
    • The low-frequency response of electrocardiographs, a frequent source of recording errors
    • Berson A.S., and Pipberger H.V. The low-frequency response of electrocardiographs, a frequent source of recording errors. Am Heart J 71 6 (1966) 779
    • (1966) Am Heart J , vol.71 , Issue.6 , pp. 779
    • Berson, A.S.1    Pipberger, H.V.2
  • 5
    • 0025095175 scopus 로고
    • Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, American Heart Association
    • Bailey J.J., Berson A.S., Garson Jr. A., Horan L.G., Macfarlane P.W., Mortara D.W., et al. Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, American Heart Association. Circulation 81 2 (1990) 730
    • (1990) Circulation , vol.81 , Issue.2 , pp. 730
    • Bailey, J.J.1    Berson, A.S.2    Garson Jr., A.3    Horan, L.G.4    Macfarlane, P.W.5    Mortara, D.W.6
  • 6
    • 0021837982 scopus 로고
    • Artefactual ST segment abnormalities due to electrocardiograph design
    • Tayler D.I., and Vincent R. Artefactual ST segment abnormalities due to electrocardiograph design. Br Heart J 54 2 (1985) 121
    • (1985) Br Heart J , vol.54 , Issue.2 , pp. 121
    • Tayler, D.I.1    Vincent, R.2
  • 7
    • 0036928433 scopus 로고    scopus 로고
    • Brugada oder nicht-Brugada: Fehldiagnose durch gerätbedingtes EKG-Artefakt
    • Martius P., and Krämer H. Brugada oder nicht-Brugada: Fehldiagnose durch gerätbedingtes EKG-Artefakt. Z Kardiol 91 (2002) 1061
    • (2002) Z Kardiol , vol.91 , pp. 1061
    • Martius, P.1    Krämer, H.2
  • 8
    • 0020042066 scopus 로고
    • Frequency response characteristics of ambulatory ECG monitoring systems and their implications for ST segment analysis
    • Bragg-Remschel D.A., Anderson C.M., and Winkle R.A. Frequency response characteristics of ambulatory ECG monitoring systems and their implications for ST segment analysis. Am Heart J 103 20 (1982) 20
    • (1982) Am Heart J , vol.103 , Issue.20 , pp. 20
    • Bragg-Remschel, D.A.1    Anderson, C.M.2    Winkle, R.A.3
  • 9
    • 0001904877 scopus 로고
    • Recommendations for standardization of leads and specifications for instruments in electrocardiography and vectocardiography. Report of the Committee on Electrocardiography, American Heart Association
    • Pipberger H.V., Arzbaecher R.C., Berson A.S., Briller S.A., Brody D.A., Flowers N.C., et al. Recommendations for standardization of leads and specifications for instruments in electrocardiography and vectocardiography. Report of the Committee on Electrocardiography, American Heart Association. Circulation 52 (1975) 11
    • (1975) Circulation , vol.52 , pp. 11
    • Pipberger, H.V.1    Arzbaecher, R.C.2    Berson, A.S.3    Briller, S.A.4    Brody, D.A.5    Flowers, N.C.6
  • 11
    • 0029348710 scopus 로고
    • ST-segment distortion in manual report mode of electrocardiographs
    • ST-segment distortion in manual report mode of electrocardiographs. Health Devices 24 8-9 (1995) 362
    • (1995) Health Devices , vol.24 , Issue.8-9 , pp. 362


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.