메뉴 건너뛰기




Volumn 50, Issue 3, 2006, Pages 278-285

Importance in optimization of multi-slice computed tomography scan protocols

Author keywords

Dose length product; Effective dose; Local diagnostic reference level; Multi slice computed tomography; Optimization; Stochastic risk

Indexed keywords

CLINICAL PROTOCOL; COMPUTED TOMOGRAPHY SCANNER; DOSIMETRY; IMAGE QUALITY; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; REVIEW; STATISTICS;

EID: 33744742997     PISSN: 00048461     EISSN: 14401673     Source Type: Journal    
DOI: 10.1111/j.1440-1673.2006.01579.x     Document Type: Review
Times cited : (14)

References (29)
  • 1
    • 33744720635 scopus 로고    scopus 로고
    • Changes in CT radiation doses in Australia from 1994 to 2002
    • Wise KN Thomson JEM. Changes in CT radiation doses in Australia from 1994 to 2002. Radiographer 2004 51 : 81 5.
    • (2004) Radiographer , vol.51 , pp. 81-5
    • Wise, K.N.1    Thomson, J.E.M.2
  • 2
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • Brenner DJ Elliston CD Hall EJ Berdon WE. Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR 2001 176 : 289 96.
    • (2001) AJR , vol.176 , pp. 289-96
    • Brenner, D.J.1    Elliston, C.D.2    Hall, E.J.3    Berdon, W.E.4
  • 3
    • 0043133867 scopus 로고    scopus 로고
    • Solid cancer risks from radiation exposure for the Australian population
    • Wise KN. Solid cancer risks from radiation exposure for the Australian population. Australas Phys Eng Sci Med 2003 26 : 53 62.
    • (2003) Australas Phys Eng Sci Med , vol.26 , pp. 53-62
    • Wise, K.N.1
  • 4
    • 4143081306 scopus 로고    scopus 로고
    • Estimated radiation risks potentially associated with full-body CT screening
    • Brenner DJ Elliston CD. Estimated radiation risks potentially associated with full-body CT screening. Radiology 2004 232 : 735 8.
    • (2004) Radiology , vol.232 , pp. 735-8
    • Brenner, D.J.1    Elliston, C.D.2
  • 5
    • 0141764894 scopus 로고    scopus 로고
    • Studies of mortality of atomic bomb survivors. Report 13: Solid cancer and noncancer disease mortality: 1950-1997
    • Preston DL Shimizu Y Pierce DA Suyama A Mabuchi K. Studies of mortality of atomic bomb survivors. Report 13: solid cancer and noncancer disease mortality: 1950-1997. Radiat Res 2003 160 : 381 407.
    • (2003) Radiat Res , vol.160 , pp. 381-407
    • Preston, D.L.1    Shimizu, Y.2    Pierce, D.A.3    Suyama, A.4    Mabuchi, K.5
  • 6
    • 1342266221 scopus 로고    scopus 로고
    • Strategies for CT radiation dose optimization
    • Kalra M Maher MM Toth TL et al. Strategies for CT radiation dose optimization. Radiology 2004 230 : 619 28.
    • (2004) Radiology , vol.230 , pp. 619-28
    • Kalra, M.1    Maher, M.M.2    Toth, T.L.3
  • 8
    • 33744726410 scopus 로고    scopus 로고
    • Factors influencing patient dose in CT
    • In: Nagel, H.D. ed. COCIR, Frankfurt
    • Nagel HD. Factors influencing patient dose in CT. In : Nagel HD ed Radiation Exposure in Computed Tomography. COCIR, Frankfurt, 2000 25 43.
    • (2000) Radiation Exposure in Computed Tomography. , pp. 25-43
    • Nagel, H.D.1
  • 9
    • 21844479031 scopus 로고    scopus 로고
    • Patient doses in multi-slice CT and the importance of optimisation
    • Heggie JCP. Patient doses in multi-slice CT and the importance of optimisation. Australas Eng Phys Sci Med 2005 28 : 86 96.
    • (2005) Australas Eng Phys Sci Med , vol.28 , pp. 86-96
    • Heggie, J.C.P.1
  • 10
    • 33744719976 scopus 로고    scopus 로고
    • ImPACT Patient Dosimetry Calculator, Version 0.99w, 2005 [accessed 1 Aug 2005]. Available from
    • ImPACT Patient Dosimetry Calculator, Version 0.99w, 2005 [accessed 1 Aug 2005]. Available from http://www.impactscan.org
  • 11
    • 33744750764 scopus 로고    scopus 로고
    • Standards Australia & Standards New Zealand. Medical electrical equipment - Part 2.44: particular requirements for safety-X-ray equipment for computed tomography. AS/NZS 3200.2.44: Standards Australia, Sydney
    • Standards Australia & Standards New Zealand. Medical electrical equipment - Part 2.44: particular requirements for safety-X-ray equipment for computed tomography. AS/NZS 3200.2.44 : Standards Australia, Sydney, 2005.
    • (2005)
  • 12
    • 0025930020 scopus 로고
    • 1990 recommendations of the international commission on radiological protection. ICRP Publication 60
    • International Commission on Radiological Protection.
    • International Commission on Radiological Protection. 1990 recommendations of the international commission on radiological protection. ICRP Publication 60. Ann ICRP 1991 21 : 1 3.
    • (1991) Ann ICRP , vol.21 , pp. 1-3
  • 13
    • 84992861239 scopus 로고    scopus 로고
    • Radiological protection and safety in medicine
    • International Commission on Radiological Protection. ICRP Publication 73.
    • International Commission on Radiological Protection. Radiological protection and safety in medicine. ICRP Publication 73. Ann ICRP 1996 26 : 2.
    • (1996) Ann ICRP , vol.26 , pp. 2
  • 14
    • 4143130955 scopus 로고    scopus 로고
    • Managing patient dose in digital radiology
    • International Commission on Radiological Protection. ICRP Publication 93.
    • International Commission on Radiological Protection. Managing patient dose in digital radiology. ICRP Publication 93. Ann ICRP 2004 34 : 1.
    • (2004) Ann ICRP , vol.34 , pp. 1
  • 16
    • 0032744531 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation: I Simulation studies
    • Gies M Kalender WA Wolf H Suess C Madsen MT. Dose reduction in CT by anatomically adapted tube current modulation: I Simulation studies. Med Phys 1999 26 : 2235 47.
    • (1999) Med Phys , vol.26 , pp. 2235-47
    • Gies, M.1    Kalender, W.A.2    Wolf, H.3    Suess, C.4    Madsen, M.T.5
  • 17
    • 0032742081 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation: II Phantom measurements
    • Kalender WA Wolf H Suess C. Dose reduction in CT by anatomically adapted tube current modulation: II Phantom measurements. Med Phys 1999 26 : 2248 53.
    • (1999) Med Phys , vol.26 , pp. 2248-53
    • Kalender, W.A.1    Wolf, H.2    Suess, C.3
  • 18
    • 32744470972 scopus 로고    scopus 로고
    • MHRA; 2005 Feb Report No.: 05016. Medicine & Healthcare Products Regulatory Agency, London.
    • Keats N. CT scanner automatic exposure control systems. MHRA; 2005 Feb Report No.: 05016. Medicine & Healthcare Products Regulatory Agency, London.
    • CT Scanner Automatic Exposure Control Systems
    • Keats, N.1
  • 19
    • 13244297711 scopus 로고    scopus 로고
    • Techniques and applications of automatic tube current modulation for CT
    • Kalra M Maher MM Toth TL et al. Techniques and applications of automatic tube current modulation for CT. Radiology 2004 233 : 649 57.
    • (2004) Radiology , vol.233 , pp. 649-57
    • Kalra, M.1    Maher, M.M.2    Toth, T.L.3
  • 20
    • 3242783182 scopus 로고    scopus 로고
    • Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis
    • Kalra M Maher MM Toth TL et al. Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology 2004 232 : 347 53.
    • (2004) Radiology , vol.232 , pp. 347-53
    • Kalra, M.1    Maher, M.M.2    Toth, T.L.3
  • 21
    • 4644221703 scopus 로고    scopus 로고
    • Sixteen-detector row CT of abdomen and pelvis: Study for optimization of Z-axis modulation technique performed in 153 patients
    • Kalra MK Maher MM Kamath RS et al. Sixteen-detector row CT of abdomen and pelvis: study for optimization of Z-axis modulation technique performed in 153 patients. Radiology 2004 233 : 241 9.
    • (2004) Radiology , vol.233 , pp. 241-9
    • Kalra, M.K.1    Maher, M.M.2    Kamath, R.S.3
  • 22
    • 0041343248 scopus 로고    scopus 로고
    • Dose reduction in multi-detector CT using attenuation-based online tube modulation
    • Tack D De Maertelaer V Gevenois PA. Dose reduction in multi-detector CT using attenuation-based online tube modulation. AJR 2003 181 : 331 4.
    • (2003) AJR , vol.181 , pp. 331-4
    • Tack, D.1    De Maertelaer, V.2    Gevenois, P.A.3
  • 23
    • 0346848753 scopus 로고    scopus 로고
    • Multi-detector row spiral CT angiography of the thoracic outlet: Dose reduction with anatomically adapted online tube current modulation and preset dose savings
    • Mastora I Remy-Jardine M Delannoy V et al. Multi-detector row spiral CT angiography of the thoracic outlet: dose reduction with anatomically adapted online tube current modulation and preset dose savings. Radiology 2004 230 : 116 24.
    • (2004) Radiology , vol.230 , pp. 116-24
    • Mastora, I.1    Remy-Jardine, M.2    Delannoy, V.3
  • 24
    • 25144448621 scopus 로고    scopus 로고
    • Chest CT performed with z-axis modulation: Scanning protocol and radiation dose
    • Kalra MK Maher MM Halpern EF et al. Chest CT performed with z-axis modulation: scanning protocol and radiation dose. Radiology 2005 237 : 303 8.
    • (2005) Radiology , vol.237 , pp. 303-8
    • Kalra, M.K.1    Maher, M.M.2    Halpern, E.F.3
  • 25
    • 17644389579 scopus 로고    scopus 로고
    • Detection of urinary tract stones at low radiation dose CT with z-axis automatic tube current modulation: Phantom and clinical studies
    • Kalra MK Maher MM D'Souza RV et al. Detection of urinary tract stones at low radiation dose CT with z-axis automatic tube current modulation: phantom and clinical studies. Radiology 2005 235 : 523 9.
    • (2005) Radiology , vol.235 , pp. 523-9
    • Kalra, M.K.1    Maher, M.M.2    D'Souza, R.V.3
  • 26
    • 25144433343 scopus 로고    scopus 로고
    • Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: Clinical evaluation
    • Mulkens TH Bellinck P Baeyaert M et al. Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 2005 237 : 213 23.
    • (2005) Radiology , vol.237 , pp. 213-23
    • Mulkens, T.H.1    Bellinck, P.2    Baeyaert, M.3
  • 27
    • 13244284587 scopus 로고    scopus 로고
    • Dose reduction in multislice computed tomography
    • Hundt W Rust F Stabler A et al. Dose reduction in multislice computed tomography. J Comput Assist Tomogr 2005 29 : 140 47.
    • (2005) J Comput Assist Tomogr , vol.29 , pp. 140-47
    • Hundt, W.1    Rust, F.2    Stabler, A.3
  • 28
    • 0345472505 scopus 로고    scopus 로고
    • Guidelines on patient dose to promote the optimisation of protection for diagnostic medical procedures
    • National Radiological Protection Board.
    • National Radiological Protection Board. Guidelines on patient dose to promote the optimisation of protection for diagnostic medical procedures. Documents of the NRPB 1999 10 : 1.
    • (1999) Documents of the NRPB , vol.10 , pp. 1
  • 29
    • 33744774371 scopus 로고    scopus 로고
    • Doses from computed tomography examinations in the UK - 2003 review; 2005 Mar Report No.: NRPB-W67. National Radiological Protection Board, Didcot.
    • Shrimpton PC Hillier MC Lewis MA Dunn M. Doses from computed tomography examinations in the UK - 2003 review; 2005 Mar Report No.: NRPB-W67. National Radiological Protection Board, Didcot.
    • Shrimpton, P.C.1    Hillier, M.C.2    Lewis, M.A.3    Dunn, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.