Bedside safety rails: Assessment of strength requirements and the appropriateness of current designs

Author keywords

Bed rails; Bedside rails; Cot sides; Design specifications; Entrapment; Force exertions; Safety standards

Indexed keywords

BENDING MOMENTS; LOAD TESTING; LOADS (FORCES); RIGIDITY; SPECIFICATIONS; STANDARDS; STRENGTH OF MATERIALS; STRUCTURAL DESIGN;

EID: 33744740973     PISSN: 00140139     EISSN: 13665847     Source Type: Journal    
DOI: 10.1080/00140130500476292     Document Type: Article
Times cited : (4)

References (23)
  • 1
    • 33744762933 scopus 로고    scopus 로고
    • Bedside Safety Rails: An Ergonomics Evaluation. Health and Safety Laboratory Report
    • No. ERG/02/07. Sheffield: Health and Safety Laboratory
    • Boocock, M. and McIlroy, R. and Weyman, A.(2002) Bedside Safety Rails: An Ergonomics Evaluation. Health and Safety Laboratory Report No. ERG/02/ 07. Sheffield: Health and Safety Laboratory.
    • (2002)
    • Boocock, M.1    McIlroy, R.2    Weyman, A.3
  • 2
    • 33744744295 scopus 로고    scopus 로고
    • Ergonomics safety implications for the design and usability of bedside safety rails
    • In 10th International Conference on Human Aspects of Advanced Manufacturing: Agility and Hybrid Automation (HAAMAHA), 3rd International Conference on Ergonomics and Safety for Global Business Quality and Productivity (Ergon-Axia) and 1st International Symposium on Theoretical Issues in Ergonomics Science (TIES), San Diego: University of San Diego
    • Boocock, M. and Weyman, A. and McIlroy, R.(2005) Ergonomics safety implications for the design and usability of bedside safety rails. In In 10th International Conference on Human Aspects of Advanced Manufacturing: Agility and Hybrid Automation (HAAMAHA), 3rd International Conference on Ergonomics and Safety for Global Business Quality and Productivity (Ergon-Axia) and 1st International Symposium on Theoretical Issues in Ergonomics Science (TIES). (pp. 18-21). San Diego: University of San Diego.
    • (2005) , pp. 18-21
    • Boocock, M.1    Weyman, A.2    McIlroy, R.3
  • 3
    • 0001875213 scopus 로고    scopus 로고
    • The legal and medical aspects of physical restraints and bed siderails and their relationship to falls and fall-related injuries in nursing homes
    • Braun, J. and Capezuti, E. (2000) The legal and medical aspects of physical restraints and bed siderails and their relationship to falls and fall-related injuries in nursing homes. DePaul Journal of Health Care Law, 4, pp. 1-72.
    • (2000) DePaul Journal of Health Care Law , vol.4 , pp. 1-72
    • Braun, J.1    Capezuti, E.2
  • 4
    • 33744756920 scopus 로고    scopus 로고
    • Strength Data for Design Safety - Phase 1, Government Consumer Safety Research
    • Department of Trade and Industry. URN 00/1070 London: The Department of Trade and Industry. Report No
    • Department of Trade and Industry.(2000) Strength Data for Design Safety - Phase 1, Government Consumer Safety Research. London: The Department of Trade and Industry. Report No. URN 00/1070
    • (2000)
  • 5
    • 0029091935 scopus 로고
    • Proposed manual handling international and European standards
    • Dickinson, C. (1995) Proposed manual handling international and European standards. Applied Ergonomics, 26, pp. 265-270.
    • (1995) Applied Ergonomics , vol.26 , pp. 265-270
    • Dickinson, C.1
  • 6
    • 84859588137 scopus 로고    scopus 로고
    • Medical Electrical Equipment - Part 2-38: Particular Requirements for the Safety of Electrically Operated Hospital Beds
    • European Committee for Standardisation. EN 60601-2-38: 1997 Brussels: European Committee for Standardisation
    • European Committee for Standardisation.(1997) EN 60601-2-38: 1997 Medical Electrical Equipment - Part 2-38: Particular Requirements for the Safety of Electrically Operated Hospital Beds. Brussels: European Committee for Standardisation.
    • (1997)
  • 7
    • 17144406986 scopus 로고    scopus 로고
    • Adjustable Beds for Disabled Persons - Requirements and Test Methods
    • European Committee for Standardisation. EN 1970:2000: Brussels: European Committee for Standardisation
    • European Committee for Standardisation.(2000) EN 1970:2000: Adjustable Beds for Disabled Persons - Requirements and Test Methods. Brussels: European Committee for Standardisation.
    • (2000)
  • 8
    • 33744729885 scopus 로고    scopus 로고
    • Hospital beds and the vulnerable patient
    • Food and Drug Administration. Available online at: (accessed 18 June 2004)
    • Food and Drug Administration.(1999) Hospital beds and the vulnerable patient. Available online at: http://www.fda.gov/cdrh/beds/ (accessed 18 June 2004)
    • (1999)
  • 9
    • 33744720646 scopus 로고    scopus 로고
    • A guide to bed safety. In Bed rails in hospitals, nursing homes and home health care: The facts
    • Food and Drug Administration. Available online at: (accessed 18 June 2004)
    • Food and Drug Administration.(2000) A guide to bed safety. In Bed rails in hospitals, nursing homes and home health care: The facts. Available online at: http://www.fda.gov/cdrh/beds/ (accessed 18 June 2004)
    • (2000)
  • 10
    • 0043174019 scopus 로고    scopus 로고
    • Clinical guidance for the assessment and implementation of bed rails in hospitals, long term care facilities, and home care settings
    • Hospital Bed Safety Work Group
    • Hospital Bed Safety Work Group. (2003) Clinical guidance for the assessment and implementation of bed rails in hospitals, long term care facilities, and home care settings Critical Care Nursing Quarterly, 26, pp. 244-254.
    • (2003) Critical Care Nursing Quarterly , vol.26 , pp. 244-254
  • 11
    • 33744755290 scopus 로고    scopus 로고
    • Bed Sides Rails (Cotsides): Risk of Entrapment. London: Medical Devices Agency
    • Medical Devices Agency. Hazard Notice HN9711
    • Medical Devices Agency.(1997) Bed Sides Rails (Cotsides): Risk of Entrapment. London: Medical Devices Agency. Hazard Notice HN9711
    • (1997)
  • 12
    • 1842850967 scopus 로고    scopus 로고
    • Bed Sides Rails (Cotsides) Fitted with Telescoping Crossbars: Risk of Movement and Subsequent Patient Injury
    • Medical Devices Agency. London: Medical Devices Agency. Safety Notice, SN 1999
    • Medical Devices Agency.(1999) Bed Sides Rails (Cotsides) Fitted with Telescoping Crossbars: Risk of Movement and Subsequent Patient Injury. London: Medical Devices Agency. Safety Notice, SN 1999
    • (1999)
  • 13
    • 17144362248 scopus 로고    scopus 로고
    • Bed Sides Rails (Cotsides): Risk of Entrapment and Asphyxiation
    • Medical Devices Agency. London: Medical Devices Agency. Hazard Notice HN2000(10)
    • Medical Devices Agency.(2000) Bed Sides Rails (Cotsides): Risk of Entrapment and Asphyxiation. London: Medical Devices Agency. Hazard Notice HN2000(10)
    • (2000)
  • 14
    • 17144368148 scopus 로고    scopus 로고
    • Advice on the Safe Use of Bed Rails
    • Medical Devices Agency. London: Medical Devices Agency. Device Bulletin DB2001 (04)
    • Medical Devices Agency.(2001) Advice on the Safe Use of Bed Rails. London: Medical Devices Agency. Device Bulletin DB2001 (04)
    • (2001)
  • 15
    • 33744723373 scopus 로고    scopus 로고
    • Bed Safety Equipment: An Evaluation, Equipment for Daily Living
    • Medical Devices Agency. London: Medical Devices Agency. Report No. EL8
    • Medical Devices Agency.(2002) Bed Safety Equipment: An Evaluation, Equipment for Daily Living. London: Medical Devices Agency. Report No. EL8
    • (2002)
  • 16
    • 0032533320 scopus 로고    scopus 로고
    • Pictures of fatal bedrail entrapment
    • Miles, S. and Parker, K. (1998) Pictures of fatal bedrail entrapment. American Family Physician, 58, pp. 1755-1760.
    • (1998) American Family Physician , vol.58 , pp. 1755-1760
    • Miles, S.1    Parker, K.2
  • 17
    • 0029878480 scopus 로고    scopus 로고
    • A case of death by physical restraint: New lessons from a photograph
    • Miles, S. (1996) A case of death by physical restraint: New lessons from a photograph. Journal of the American Geriatrics Society, 44, pp. 291-292.
    • (1996) Journal of the American Geriatrics Society , vol.44 , pp. 291-292
    • Miles, S.1
  • 18
    • 0036081747 scopus 로고    scopus 로고
    • Deaths between bedrails and air pressure mattresses
    • Miles, S. (2002) Deaths between bedrails and air pressure mattresses. Journal of the American Geriatrics Society, 50, pp. 1124-1125.
    • (2002) Journal of the American Geriatrics Society , vol.50 , pp. 1124-1125
    • Miles, S.1
  • 19
    • 0026471213 scopus 로고
    • Deaths caused by physical restraints
    • Miles, S. and Irvine, P. (1992) Deaths caused by physical restraints. Gerontologist, 32, pp. 762-766.
    • (1992) Gerontologist , vol.32 , pp. 762-766
    • Miles, S.1    Irvine, P.2
  • 21
    • 33744767640 scopus 로고    scopus 로고
    • PeopleSize 2000 Professional
    • PeopleSize. Loughborough Leicestershire: Open Ergonomics Ltd
    • PeopleSize.(2000) PeopleSize 2000 Professional. Loughborough Leicestershire: Open Ergonomics Ltd..
    • (2000)
  • 23
    • 0030660139 scopus 로고    scopus 로고
    • Injury and death associated with hospital bed side-rails: Reports to the US Food and Drug Administration from 1985 to 1995
    • Todd, J. and Ruhl, C. and Gross, T. (1997) Injury and death associated with hospital bed side-rails: Reports to the US Food and Drug Administration from 1985 to 1995. American Journal of Public Health, 87, pp. 1675-1677.
    • (1997) American Journal of Public Health , vol.87 , pp. 1675-1677
    • Todd, J.1    Ruhl, C.2    Gross, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.