Volumn 3032, Issue , 1997, Pages 161-170

Performance assessment of the scanning beam digital x-ray (SBDX) system

Author keywords

Digital fluoroscopy; Exposure reduction; Scanning x ray source; X ray scatter

Indexed keywords

ELECTRON SOURCES; FLUORESCENT SCREENS; IMAGE QUALITY; SCANNING; X RAY APPARATUS; X RAYS;

EID: 33744699991     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.273981     Document Type: Conference Paper
Times cited : (8)

References (11)
  • 2
    • 0030228293 scopus 로고    scopus 로고
    • Radiation-induced skin injuries from fluoroscopy
    • T.B. Shope, "Radiation-induced skin injuries from fluoroscopy," Radiographics 16, 1195-1199 (1996).
    • (1996) Radiographics , vol.16 , pp. 1195-1199
    • Shope, T.B.1
  • 4
    • 0028360924 scopus 로고
    • Comparison of the low-contrast detectability of a screen-film system and third generation computed radiography
    • L.T. Cook, M.F. Insana, M.A. McFadden, T.J. Hall, G.G. Cox, "Comparison of the low-contrast detectability of a screen-film system and third generation computed radiography," Med. Phys. 21, 691-695 (1994).
    • (1994) Med. Phys , vol.21 , pp. 691-695
    • Cook, L.T.1    Insana, M.F.2    McFadden, M.A.3    Hall, T.J.4    Cox, G.G.5
  • 6
    • 0001755416 scopus 로고
    • The physical evaluation of the imaging performance of television fluoroscopy and digital fluorography systems using the Leeds x-ray test objects: A UK approach to quality assurance in the diagnostic radiology department
    • J.A. Seibert, G.T. Barnes, R.G. Gould, editors, American Association of Physicists in Medicine
    • A.R. Cowen, "The physical evaluation of the imaging performance of television fluoroscopy and digital fluorography systems using the Leeds x-ray test objects: A UK approach to quality assurance in the diagnostic radiology department," In J.A. Seibert, G.T. Barnes, R.G. Gould, editors, Specification, Acceptance Testing and Quality Control of Diagnostic X-ray Imaging Equipment, pp. 499-568, American Association of Physicists in Medicine (1994).
    • (1994) Specification, Acceptance Testing and Quality Control of Diagnostic X-ray Imaging Equipment , pp. 499-568
    • Cowen, A.R.1
  • 7
    • 0025156139 scopus 로고
    • Origins of flare in x-ray image intensifiers
    • R. Luhta and J.A. Rowlands, "Origins of flare in x-ray image intensifiers," Med. Phys. 17, 913-921 (1990).
    • (1990) Med. Phys , vol.17 , pp. 913-921
    • Luhta, R.1    Rowlands, J.A.2
  • 8
    • 0021609521 scopus 로고
    • Noise power spectrum, MTF, and DQE of photoelectronic radiographic systems, Application of Optical Instrumentation in Medicine XII
    • T. Fu and H. Roehrig, "Noise power spectrum, MTF, and DQE of photoelectronic radiographic systems," Application of Optical Instrumentation in Medicine XII, SPIE Proc. 454, 377-386 (1984).
    • (1984) SPIE Proc , vol.454 , pp. 377-386
    • Fu, T.1    Roehrig, H.2
  • 10
    • 0028921566 scopus 로고
    • Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems
    • J.T. Dobbins III, "Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems," Med. Phys. 22, 171-181 (1995).
    • (1995) Med. Phys , vol.22 , pp. 171-181
    • Dobbins III, J.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.