Wedging the Pulmonary Artery Catheter: Changes in Left Atrial and Pulmonary Artery Pressures and Risk for Perforation

Author keywords

aneurysm; atrial pressure; catheterization; false; pulmonary artery catheter; pulmonary artery perforation

Indexed keywords

ADULT; AGED; ARTERY INJURY; ARTICLE; ARTIFICIAL VENTILATION; CARDIOPULMONARY BYPASS; CLINICAL ARTICLE; CONTROLLED STUDY; EPIDURAL CATHETER; FEMALE; HEART INDEX; HEART LEFT ATRIUM; HEART LEFT ATRIUM PRESSURE; HEART OUTPUT MEASUREMENT; HUMAN; INTENSIVE CARE UNIT; LUNG ARTERY PRESSURE; LUNG WEDGE PRESSURE; MALE; MEAN ARTERIAL PRESSURE; OPEN HEART SURGERY; OPERATING ROOM; PRIORITY JOURNAL; PULMONARY ARTERY CATHETER; PULMONARY ARTERY INJURY; UNIVERSITY HOSPITAL;

EID: 33646907663     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.jvca.2005.05.022     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter
    • Swan H.J.C., Ganz W., Forrester J., et al. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med 283 (1970) 447-451
    • (1970) N Engl J Med , vol.283 , pp. 447-451
    • Swan, H.J.C.1    Ganz, W.2    Forrester, J.3
  • 2
    • 0021688508 scopus 로고
    • Hypotension secondary to balloon inflation of a pulmonary artery catheter
    • Willis C., Wight D., and Zidulka A. Hypotension secondary to balloon inflation of a pulmonary artery catheter. Crit Care Med 12 (1984) 915-917
    • (1984) Crit Care Med , vol.12 , pp. 915-917
    • Willis, C.1    Wight, D.2    Zidulka, A.3
  • 3
    • 0027315091 scopus 로고
    • Pulmonary arterial wedge pressure measurement can modify pulmonary haemodynamics in patients with chronic lung disease
    • Schrijen F.V., Serria A., and Chanbot F. Pulmonary arterial wedge pressure measurement can modify pulmonary haemodynamics in patients with chronic lung disease. Clin Physiol 13 (1993) 289-298
    • (1993) Clin Physiol , vol.13 , pp. 289-298
    • Schrijen, F.V.1    Serria, A.2    Chanbot, F.3
  • 4
    • 0347296027 scopus 로고    scopus 로고
    • Nitric oxide increases dramatically in air exhaled from lung regions with occluded vessels
    • Fernandéz-Mondéjar E., Hambraeus-Jonzon K., Roneus A., et al. Nitric oxide increases dramatically in air exhaled from lung regions with occluded vessels. Acta Anaesthesiol Scand 47 (2003) 312-318
    • (2003) Acta Anaesthesiol Scand , vol.47 , pp. 312-318
    • Fernandéz-Mondéjar, E.1    Hambraeus-Jonzon, K.2    Roneus, A.3
  • 5
    • 0002835580 scopus 로고
    • Left auricular pressure measurements in man
    • Björk V.O., Malmström G., and Uggla L.G. Left auricular pressure measurements in man. Ann Surg 138 (1953) 718-725
    • (1953) Ann Surg , vol.138 , pp. 718-725
    • Björk, V.O.1    Malmström, G.2    Uggla, L.G.3
  • 7
    • 0015611142 scopus 로고
    • Indirect measurements of left atrial pressure in surgical patients. Pulmonary capillary wedge and pulmonary artery diastolic pressures compared with left atrial pressure
    • Lappas D., Lell W.A., Gabel J.C., et al. Indirect measurements of left atrial pressure in surgical patients. Pulmonary capillary wedge and pulmonary artery diastolic pressures compared with left atrial pressure. Anesthesiology 38 (1973) 394-397
    • (1973) Anesthesiology , vol.38 , pp. 394-397
    • Lappas, D.1    Lell, W.A.2    Gabel, J.C.3
  • 8
    • 0020309832 scopus 로고
    • Inaccuracy of pulmonary capillary wedge pressure when compared to left atrial pressure in the early postsurgical period
    • Mammana R.B., Hiro S., Levitsky S., et al. Inaccuracy of pulmonary capillary wedge pressure when compared to left atrial pressure in the early postsurgical period. J Thorac Cardiovasc Surg 84 (1982) 420-425
    • (1982) J Thorac Cardiovasc Surg , vol.84 , pp. 420-425
    • Mammana, R.B.1    Hiro, S.2    Levitsky, S.3
  • 9
    • 0025094558 scopus 로고
    • Pulmonary artery occlusion pressure is not accurate immediately after cardiopulmonary bypass
    • Entress J.J., Dhamee M.S., Olund T., et al. Pulmonary artery occlusion pressure is not accurate immediately after cardiopulmonary bypass. J Cardiothorac Anesth 4 (1990) 558-563
    • (1990) J Cardiothorac Anesth , vol.4 , pp. 558-563
    • Entress, J.J.1    Dhamee, M.S.2    Olund, T.3
  • 10
    • 0035680810 scopus 로고    scopus 로고
    • Swan-Ganz catheter-induced pulmonary artery pseudoaneurysm formation. Three case reports and a review of the literature
    • Poplausky M.R., Rozenblit G., Rundback J.H., et al. Swan-Ganz catheter-induced pulmonary artery pseudoaneurysm formation. Three case reports and a review of the literature. Chest 120 (2001) 2105-2111
    • (2001) Chest , vol.120 , pp. 2105-2111
    • Poplausky, M.R.1    Rozenblit, G.2    Rundback, J.H.3
  • 11
    • 14844335085 scopus 로고    scopus 로고
    • Pulmonary artery rupture induced by a pulmonary artery catheter. A case report and review of the literature
    • Abreu A.R., Campos M.A., and Krieger B.P. Pulmonary artery rupture induced by a pulmonary artery catheter. A case report and review of the literature. J Intens Care Med 19 (2004) 291-296
    • (2004) J Intens Care Med , vol.19 , pp. 291-296
    • Abreu, A.R.1    Campos, M.A.2    Krieger, B.P.3
  • 12
    • 0028806217 scopus 로고
    • Pulmonary artery rupture associated with the Swan-Ganz catheter
    • Kearny T.J., and Shabot M.M. Pulmonary artery rupture associated with the Swan-Ganz catheter. Chest 108 (1995) 1349-1352
    • (1995) Chest , vol.108 , pp. 1349-1352
    • Kearny, T.J.1    Shabot, M.M.2
  • 13
    • 33646916352 scopus 로고    scopus 로고
    • Pulmonary artery (Swan-Ganz) catheter
    • Maltby J.R. (Ed), The Royal Society of Medicine Press, London, UK
    • Swan H.J.C. Pulmonary artery (Swan-Ganz) catheter. In: Maltby J.R. (Ed). Notable names in anaesthesia (2002), The Royal Society of Medicine Press, London, UK 209-212
    • (2002) Notable names in anaesthesia , pp. 209-212
    • Swan, H.J.C.1
  • 14
    • 0015212676 scopus 로고
    • Perforation of the pulmonary artery by a Swan-Ganz catheter
    • Chun G.M.H., and Ellestad M.H. Perforation of the pulmonary artery by a Swan-Ganz catheter. N Engl J Med 284 (1971) 1041-1042
    • (1971) N Engl J Med , vol.284 , pp. 1041-1042
    • Chun, G.M.H.1    Ellestad, M.H.2