메뉴 건너뛰기




Volumn 17, Issue 6, 2006, Pages 1579-1585

Highly accurate measurement of oxygen using a paramagnetic gas sensor

Author keywords

Analytical measurement; Gas; Instrumentation; Metrology; Oxygen; Paramagnetic; Primary standard gas mixture; Sensor

Indexed keywords

GASES; MIXTURES; NITROGEN; OXYGEN;

EID: 33646896946     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/17/6/040     Document Type: Conference Paper
Times cited : (18)

References (13)
  • 1
    • 0007373622 scopus 로고
    • The measurement of oxygen in gas mixtures
    • 0022-3735 001
    • Kocache R 1986 The measurement of oxygen in gas mixtures J. Phys. E: Sci. Instrum. 19 401
    • (1986) J. Phys. E: Sci. Instrum. , vol.19 , Issue.6 , pp. 401
    • Kocache, R.1
  • 2
    • 33646868253 scopus 로고
    • The measurement of oxygen by its magnetic property
    • Kocache R 1991 The measurement of oxygen by its magnetic property Techniques and Mechanisms in Gas Sensing (Bristol: Hilger) p 198
    • (1991) Techniques and Mechanisms in Gas Sensing , pp. 198
    • Kocache, R.1
  • 3
    • 85034756111 scopus 로고    scopus 로고
    • The UK National Air Quality Information Archive
    • The UK National Air Quality Information Archive Air Pollution-Current Maximum Levels http://www.airquality.co.uk/archive/bulletin.php?typeCombining double low lineCurrent
    • Air Pollution-Current Maximum Levels
  • 5
    • 0000939224 scopus 로고
    • An instrument for determining the partial pressure of oxygen in a gas
    • 10.1021/ja01209a029 0002-7863
    • Pauling L, Wood R E and Sturdivant J H 1946 An instrument for determining the partial pressure of oxygen in a gas J. Am. Chem. Soc. 68 795
    • (1946) J. Am. Chem. Soc. , vol.68 , Issue.5 , pp. 795
    • Pauling, L.1    Wood, R.E.2    Sturdivant, J.H.3
  • 7
    • 0014318108 scopus 로고
    • The measurement of gaseous oxygen tension utilizing paramagnetism: An evaluation of the 'Servomex' OA.150 analyzer
    • 0007-0912
    • Ellis F R and Nunn J F 1968 The measurement of gaseous oxygen tension utilizing paramagnetism: an evaluation of the 'Servomex' OA.150 analyzer Br. J. Anaesth. 40 569
    • (1968) Br. J. Anaesth. , vol.40 , pp. 569
    • Ellis, F.R.1    Nunn, J.F.2
  • 10
    • 0014006012 scopus 로고
    • A comparison of paramagnetic and chemical methods for the determination of oxygen
    • Shephard R J 1966 A comparison of paramagnetic and chemical methods for the determination of oxygen Int. Z. Angew. Physiol. 22 279
    • (1966) Int. Z. Angew. Physiol. , vol.22 , pp. 279
    • Shephard, R.J.1
  • 11
    • 4243283366 scopus 로고
    • A comparison between 27 laboratories of the results of analysis of an expired gas sample
    • Cotes J E and Woolmer R F 1962 A comparison between 27 laboratories of the results of analysis of an expired gas sample J. Physiol. 163 36
    • (1962) J. Physiol. , vol.163 , pp. 36
    • Cotes, J.E.1    Woolmer, R.F.2
  • 12
    • 33646856722 scopus 로고
    • Applications of gas analysis: IV. The Haldane gas analyzer
    • 0021-9258
    • Henderson Y 1918 Applications of gas analysis: IV. The Haldane gas analyzer J. Biol. Chem. 33 31
    • (1918) J. Biol. Chem. , vol.33 , pp. 31
    • Henderson, Y.1
  • 13
    • 0036082772 scopus 로고    scopus 로고
    • Uncertainty reduction due to correlation effects in weighing during the preparation of primary gas standards
    • 0026-1394 12
    • Milton M J T M, Woods P T and Holland P E 2002 Uncertainty reduction due to correlation effects in weighing during the preparation of primary gas standards Metrologia 39 97
    • (2002) Metrologia , vol.39 , Issue.1 , pp. 97
    • Milton, M.J.T.M.1    Woods, P.T.2    Holland, P.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.