1
-
-
33646862930
-
-
Balsamo EP et al. Final tests of the SULTAN 12T facility in the split coil configuration. In: 17th Symp on Fusion Tech Proc, Rome, Italy, 1992.
-
-
-
-
2
-
-
22044454722
-
Design and manufacture of a full size joint sample for the qualification of the Poloidal Field Insert Coil
-
Hurd F., et al. Design and manufacture of a full size joint sample for the qualification of the Poloidal Field Insert Coil. IEEE Trans Appl Supercond (2005)
-
(2005)
IEEE Trans Appl Supercond
-
-
Hurd, F.1
-
3
-
-
33646890790
-
-
ITER Team, FDR, How J. Project integration document. ITER the way to fusion energy, release 2.0, September 2005.
-
-
-
-
4
-
-
0033907787
-
Dual channel Cable-In-Conduit thermohydraulics: influence of some design parameters
-
Nicollet S., Duchateau J.L., Fillunger H., Martinez A., and Parodi S. Dual channel Cable-In-Conduit thermohydraulics: influence of some design parameters. IEEE Trans Appl Supercond 10 (2000) 1102-1105
-
(2000)
IEEE Trans Appl Supercond
, vol.10
, pp. 1102-1105
-
-
Nicollet, S.1
Duchateau, J.L.2
Fillunger, H.3
Martinez, A.4
Parodi, S.5
-
5
-
-
0028694979
-
Optimum thermohydraulic operation regime for cable in conduit superconductors (CICS)
-
Katheder H. Optimum thermohydraulic operation regime for cable in conduit superconductors (CICS). Cryogenics 34 (1994) 595-598
-
(1994)
Cryogenics
, vol.34
, pp. 595-598
-
-
Katheder, H.1
-
6
-
-
33646874713
-
-
Marinucci C, Bruzzone P, della Corte A, Savoldi Richard L, Zanino R. Pressure drop of the ITER PFI Cable-In-Conduit-Conductor. In: ASC04 conf proc Jacksonville, USA 2LF02, 2004.
-
-
-
-
7
-
-
33646883810
-
-
Duchateau JL, Ciazynski D, Decool P, Renard B, Zani L. Task TW2-TMST-TOSKA deliverable 4: final report on the testing of a full size joint sample. Int report DRFC/AIM/NTT-2005.002 delivered to EFDA, 2005.
-
-
-
-
8
-
-
0032259451
-
AC losses and stability on large cable-in-conduit superconductors
-
Bruzzone P. AC losses and stability on large cable-in-conduit superconductors. Phys C: Supercond 310 1-4 (1998) 240-246
-
(1998)
Phys C: Supercond
, vol.310
, Issue.1-4
, pp. 240-246
-
-
Bruzzone, P.1
-
9
-
-
33646892542
-
-
Rousset B, Girard A. Preliminary analysis on Sultan{minus 45 degree rule}PFIS: enthalpy balance tests with main heaters, calibration and results concerning annular and local heaters. Communication presented at testing group meeting, Villigen, December 2004.
-
-
-
-
10
-
-
33745878568
-
-
Renard B, Duchateau JL, Rousset B, Tadrist L. Evaluation of thermal gradients and thermosiphon in dual channel Cable-In-Conduit Conductors. Cryogenics, in press, doi:10.1016/j.cryogenics.2005.07.007.
-
-
-
-
11
-
-
33646887330
-
-
Bottura L, Bruzzone P, Marinucci C, Stepanov B. Analysis of transverse heat transfer coefficient in CICCs with central cooling channel. In: CHATS conf proc TM5, Twente, Netherlands. Cryogenics, 2006;46(7-8):597-605.
-
-
-
-
12
-
-
33646891428
-
-
Nicollet S, Ciazynski D, Duchateau JL, Lacroix B, Renard B. Evaluation of the ITER Cable-In-Conduit-Conductor heat transfer. In: ICEC20 conf proc, Beijin, China, 2004.
-
-
-
-
13
-
-
33646882067
-
-
Holman JP. Heat transfer. 9th ed. Southern Methodist University, McGraw Higher Education, international edition.
-
-
-
-
14
-
-
33646867329
-
-
Long AE. Transverse heat transfer in a Cable-In-Conduit-Conductor with central cooling channel. MS thesis, MIT, 1995.
-
-
-
-
15
-
-
33646863136
-
-
Zanino R, Decool P, Savoldi Richard L. Status of the analysis of the HECOL transient heat transfer tests. Presented at the ITER conductor meeting, Muerren, Switzerland, January 2005.
-
-
-
-
16
-
-
33646860256
-
-
Zanino R, Bruzzone P, Ciazynski D, Ciotti M, Gislon P, Nicollet S, et al. Analysis of thermal-hydraulic gravity/buoyancy effects in the testing of the ITER Poloidal Field Full Size Joint Sample (PF-FSJS). In: Adv in cryogenic eng conf CEC 49, American Institute of Physics, 2004.
-
-
-
-
17
-
-
33646894440
-
-
Martinez A, Turck B. Supercritical helium cooling of a Cable-In-Conduit Conductor with an inner tube. Int report P/EM/93.18, 1993.
-
-
-
|