메뉴 건너뛰기




Volumn 15, Issue 1, 2006, Pages 70-76

Collagen fiber orientation near a fractured dental implant after a 5-tear loading period: Case report

Author keywords

Circularly polarized light; Collagen fiber orientation; Dental implants fractography; Implant fracture; Titanium implants

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; COLLAGEN; TITANIUM;

EID: 33646854564     PISSN: 10566163     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.id.0000202420.49004.1e     Document Type: Article
Times cited : (27)

References (28)
  • 1
    • 0022966160 scopus 로고
    • Marginal tissue reactions at osseointegrated titanium fixtures (I). A 3-year longitudinal prospective study
    • Adell R, Lekholm U, Rockler B, et al. Marginal tissue reactions at osseointegrated titanium fixtures (I). A 3-year longitudinal prospective study. Int J Oral Maxillofac Surg. 1986;15:39-52.
    • (1986) Int J Oral Maxillofac Surg. , vol.15 , pp. 39-52
    • Adell, R.1    Lekholm, U.2    Rockler, B.3
  • 2
    • 18044403181 scopus 로고    scopus 로고
    • The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: An animal experimental study
    • Duyck J, Roenold HJ, Van Oosterwyck H, et al. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: An animal experimental study. Clin Oral Implants Res. 2001;12:207-218.
    • (2001) Clin Oral Implants Res. , vol.12 , pp. 207-218
    • Duyck, J.1    Roenold, H.J.2    Van Oosterwyck, H.3
  • 3
    • 0031088442 scopus 로고    scopus 로고
    • Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible
    • Barbier L, Schepers E. Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible. Int J Oral Maxillofac Implants. 1997;12:215-223.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 215-223
    • Barbier, L.1    Schepers, E.2
  • 4
    • 0032198792 scopus 로고    scopus 로고
    • Finite element analysis of non-axial vs. axial loading of oral implants in the mandible of the dog
    • Barbier L, Vander Sloten J, Krzesinski G, et al. Finite element analysis of non-axial vs. axial loading of oral implants in the mandible of the dog. J Oral Rehabil. 1998;25: 847-858.
    • (1998) J Oral Rehabil. , vol.25 , pp. 847-858
    • Barbier, L.1    Vander Sloten, J.2    Krzesinski, G.3
  • 5
    • 0033251930 scopus 로고    scopus 로고
    • Lack of integration of smooth titanium surfaces: A working hypothesis based on strains generated in the surrounding bone
    • Wiskott HWA, Belser UC. Lack of integration of smooth titanium surfaces: A working hypothesis based on strains generated in the surrounding bone. Clin Oral Implants Res. 1999;10:429-444.
    • (1999) Clin Oral Implants Res. , vol.10 , pp. 429-444
    • Wiskott, H.W.A.1    Belser, U.C.2
  • 6
    • 0031989688 scopus 로고    scopus 로고
    • Hollow implants retrieved for fracture: A light and scanning electron microscope analysis of 4 cases
    • Piattelli A, Scarano A, Vaia E, et al. Hollow implants retrieved for fracture: A light and scanning electron microscope analysis of 4 cases. J Periodontol. 1998; 69:185-189.
    • (1998) J Periodontol. , vol.69 , pp. 185-189
    • Piattelli, A.1    Scarano, A.2    Vaia, E.3
  • 7
    • 0033158898 scopus 로고    scopus 로고
    • Multicenter retrospective analysis of the ITI implant system used for singletooth replacements. Results of loading for 2 or more years
    • Levine RA, Clem DS III, Wilson TG Jr, et al. Multicenter retrospective analysis of the ITI implant system used for singletooth replacements. Results of loading for 2 or more years. Int J Oral Maxillofac Implants. 1999;14:516-520.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 516-520
    • Levine, R.A.1    Clem III, D.S.2    Wilson Jr., T.G.3
  • 8
    • 0032110991 scopus 로고    scopus 로고
    • Light and scanning electron microscopic report of four fractured implants
    • Piattelli A, Piattelli M, Scarano A, et al. Light and scanning electron microscopic report of four fractured implants. Int J Oral Maxillofac Implants. 1998;13:561-564.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 561-564
    • Piattelli, A.1    Piattelli, M.2    Scarano, A.3
  • 10
    • 0028022458 scopus 로고
    • Survival of fixed implant-supported prostheses related to cantilever length
    • Shackleton JL, Carr L, Slabbert JCG, et al. Survival of fixed implant-supported prostheses related to cantilever length. J Prosthet Dent. 1994;71:23-26.
    • (1994) J Prosthet Dent , vol.71 , pp. 23-26
    • Shackleton, J.L.1    Carr, L.2    Slabbert, J.C.G.3
  • 11
    • 0029303274 scopus 로고
    • Bending overload and implant fracture: A retrospective clinical analysis
    • Rangert B, Krogh PHJ, Langer B, et al. Bending overload and implant fracture: A retrospective clinical analysis. Int J Oral Maxillofac Implants. 1995;10: 326-334.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 326-334
    • Rangert, B.1    Krogh, P.H.J.2    Langer, B.3
  • 12
    • 0030236468 scopus 로고    scopus 로고
    • An analysis and management of fractured implants: A clinical report
    • Balshi TJ. An analysis and management of fractured implants: A clinical report. Int J Oral Maxillofac Implants. 1996; 11:660-666.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 660-666
    • Balshi, T.J.1
  • 13
    • 0034157357 scopus 로고    scopus 로고
    • Time dependent failure rate and marginal bone loss of implant supported prostheses: A 1-year follow-up study
    • Snauwaert K, Duyck J, van Steen-berghe D, et al. Time dependent failure rate and marginal bone loss of implant supported prostheses: A 1-year follow-up study. Clin Oral Investig. 2000;4:13-20.
    • (2000) Clin Oral Investig. , vol.4 , pp. 13-20
    • Snauwaert, K.1    Duyck, J.2    Van Steen-Berghe, D.3
  • 14
    • 0035260334 scopus 로고    scopus 로고
    • Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function
    • Bragger U, Aeschlimann S, Burgin W, et al. Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function. Clin Oral Implants Res. 2001;12:26-34.
    • (2001) Clin Oral Implants Res. , vol.12 , pp. 26-34
    • Bragger, U.1    Aeschlimann, S.2    Burgin, W.3
  • 15
    • 0025583364 scopus 로고
    • A long-term follow-up study of os seointegrated implants in the treatment of totally edentulous jaws
    • Adell R, Eriksson B, Lekholm U, et al. A long-term follow-up study of os seointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants. 1990;5:347-359.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 347-359
    • Adell, R.1    Eriksson, B.2    Lekholm, U.3
  • 16
    • 0034574104 scopus 로고    scopus 로고
    • Mechanical complications of dental implants
    • Schwarz MS. Mechanical complications of dental implants. Clin Oral Implants Res. 2000;11:156-158.
    • (2000) Clin Oral Implants Res. , vol.11 , pp. 156-158
    • Schwarz, M.S.1
  • 17
    • 0035217548 scopus 로고    scopus 로고
    • The role of collagen in determining bone mechanical properties
    • Wang X, Bank RA, TeKoppele JM, et al. The role of collagen in determining bone mechanical properties. J Orthop Res. 2001;19:1021-1026.
    • (2001) J Orthop Res. , vol.19 , pp. 1021-1026
    • Wang, X.1    Bank, R.A.2    Tekoppele, J.M.3
  • 18
    • 0141892581 scopus 로고    scopus 로고
    • Circularly polarized light standards for investigations of collagen fiber orientation in bone
    • Bromage TG, Goldman HM, McFarlin SO, et al. Circularly polarized light standards for investigations of collagen fiber orientation in bone. Anat Rec. 2003;274B: 157-168.
    • (2003) Anat Rec. , vol.274 B , pp. 157-168
    • Bromage, T.G.1    Goldman, H.M.2    McFarlin, S.O.3
  • 19
    • 0036468628 scopus 로고    scopus 로고
    • Determination of the orientation of collagen fibers in human bone
    • Osaki S, Tohno S, Tohno Y, et al. Determination of the orientation of collagen fibers in human bone. Anat Rec. 2002;266: 103-107.
    • (2002) Anat Rec. , vol.266 , pp. 103-107
    • Osaki, S.1    Tohno, S.2    Tohno, Y.3
  • 20
    • 33749354467 scopus 로고    scopus 로고
    • Accessed June 3, 2005
    • US National Institutes of Health. Available at: http://rsb.info.nih.gov/ ij/download.html Accessed June 3, 2005.
  • 21
    • 0033629253 scopus 로고    scopus 로고
    • Influence of bicortical or monocortical anchorage on maxillary implant stability: A 15-year retrospective study of Brånemark system implants
    • Ivanoff CJ, Grondahl K, Bergström C, et al. Influence of bicortical or monocortical anchorage on maxillary implant stability: A 15-year retrospective study of Brånemark system implants. Int J Oral Maxillofac Implants. 2000;15:103-110.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 103-110
    • Ivanoff, C.J.1    Grondahl, K.2    Bergström, C.3
  • 23
    • 85016033318 scopus 로고
    • Mechanical loading of Brånemark implants affects interfacial bone modeling and remodeling
    • Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Brånemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants. 1994;9:345-360.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 345-360
    • Hoshaw, S.J.1    Brunski, J.B.2    Cochran, G.V.B.3
  • 24
    • 0031586908 scopus 로고    scopus 로고
    • Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospital
    • Alien PF, McMillan AS, Smith DG. Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospital. Br Dent J. 1997;182:298-302.
    • (1997) Br Dent J. , vol.182 , pp. 298-302
    • Alien, P.F.1    McMillan, A.S.2    Smith, D.G.3
  • 25
    • 0343970404 scopus 로고
    • Relations between the microscopic structure and tensile strength of human bone
    • Evans FG. Relations between the microscopic structure and tensile strength of human bone. Acta Anat (Basel). 1958; 35:285-301.
    • (1958) Acta Anat (Basel) , vol.35 , pp. 285-301
    • Evans, F.G.1
  • 26
    • 0013929640 scopus 로고
    • Dynamic response of bone and muscle tissue
    • McElhaney JH. Dynamic response of bone and muscle tissue. J Appl Physlol. 1966;21:1231-1236.
    • (1966) J Appl Physlol. , vol.21 , pp. 1231-1236
    • McElhaney, J.H.1
  • 27
    • 15944415383 scopus 로고    scopus 로고
    • Collagen fiber orientation in human periimplant bone of immediately loaded and unloaded titanium dental implants
    • Traini T, Degidi M, Caputi S, et al. Collagen fiber orientation in human periimplant bone of immediately loaded and unloaded titanium dental implants. J Periodontol. 2005;76:83-89.
    • (2005) J Periodontol. , vol.76 , pp. 83-89
    • Traini, T.1    Degidi, M.2    Caputi, S.3
  • 28
    • 21544480284 scopus 로고    scopus 로고
    • Collagen fibers orientation near dental implants in human bone: Do their organization reflect differences in loading?
    • Traini T, Degidi M, Strocchi R, et al. Collagen fibers orientation near dental implants in human bone: Do their organization reflect differences in loading? J Biomed Mater Res B Appl Biomater. 2005;74:538-546.
    • (2005) J Biomed Mater Res B Appl Biomater. , vol.74 , pp. 538-546
    • Traini, T.1    Degidi, M.2    Strocchi, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.