메뉴 건너뛰기




Volumn 12, Issue 3, 2003, Pages 101-106

Device failure of heart assist devices and their possible pathogenesis;Klappeninsuffizienz bei assist-device-systemen und deren mögliche pathogenese

Author keywords

Assist devices; Device failure; End stage heart failure; Valve regurgitation

Indexed keywords


EID: 33646847085     PISSN: 09412670     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Short Survey
Times cited : (3)

References (9)
  • 1
    • 0019965530 scopus 로고    scopus 로고
    • Structural changes of glutaraldehyde-treated porcine bioprosthetic valves
    • Camilleri JP, Pornin B, Carpentier A: Structural changes of glutaraldehyde-treated porcine bioprosthetic valves. Arch Pathol Lab Med 1996; 106(10): 490-496
    • (1996) Arch Pathol Lab Med , vol.106 , Issue.10 , pp. 490-496
    • Camilleri, J.P.1    Pornin, B.2    Carpentier, A.3
  • 4
    • 68949137929 scopus 로고    scopus 로고
    • In vitro calcification of bioprostheses: Influence of mechanical stress
    • Glasmacher B, Deiwick M, Reul H et al: In vitro calcification of bioprostheses: Influence of mechanical stress. Intern Journ Artif Organs 1998; 20: 517
    • (1998) Intern Journ Artif Organs , vol.20 , pp. 517
    • Glasmacher, B.1    Deiwick, M.2    Reul, H.3
  • 5
    • 0025449517 scopus 로고
    • Porcine aortic valve bioprostheses: A morphologic comparison of the effects of fixation pressure
    • DOI 10.1002/jbm.820240611
    • Hilbert SL, Barrick MK, Ferrans VJ: Porcine aortic valve bioprostheses: a morphologic comparison of the effects of fixation pressure. J Biomed Mater Res 1990; 24(6): 773-787 (Pubitemid 20236527)
    • (1990) Journal of Biomedical Materials Research , vol.24 , Issue.6 , pp. 773-787
    • Hilbert, S.L.1    Barrick, M.K.2    Ferrans, V.J.3
  • 6
    • 0027163768 scopus 로고
    • Long-term function of cryo-preserved aortic homografts, a ten-years study
    • Kirklin JK, Smith D, Novik W et al: Long-term function of cryo-preserved aortic homografts, A ten-years study. Journ Thorac Cardiovasc Surg 1993; 106: 154-165
    • (1993) Journ Thorac Cardiovasc Surg , vol.106 , pp. 154-165
    • Kirklin, J.K.1    Smith, D.2    Novik, W.3
  • 8
    • 0033966569 scopus 로고    scopus 로고
    • The dilemma of accelerated bioprosthetic and polymeric valve testing
    • Reul H, Potthast K: The dilemma of accelerated bioprosthetic and polymeric valve testing. Journ Heart Valve Dis 2000; 9(1): 159-160 (Pubitemid 30101811)
    • (2000) Journal of Heart Valve Disease , vol.9 , Issue.1 , pp. 159-160
    • Reul, H.1    Potthast, K.2
  • 9
    • 0029112749 scopus 로고
    • Bioprosthetic Valve Tissue Viscoelasticity: Implications on Accelerated Pulse Duplicator Testing
    • Vesely I, Boughner DR, Lesson-Dietrich J: Bioprosthetic Valve Tissue Viscoelasticity: Implications on Accelerated Pulse Duplicator Testing. Ann Thorac Surg 1995; 60: 379-381
    • (1995) Ann Thorac Surg , vol.60 , pp. 379-381
    • Vesely, I.1    Boughner, D.R.2    Lesson-Dietrich, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.