-
1
-
-
0034103920
-
Modeling flow effects on thrombotic deposition in a membrane oxygenator
-
Gartner MJ, Wilhelm CR, Gage KL, Fabrizio MC and Wagner WR: Modeling flow effects on thrombotic deposition in a membrane oxygenator. Artif Organs (2000) 24: 29-36.
-
(2000)
Artif Organs
, vol.24
, pp. 29-36
-
-
Gartner, M.J.1
Wilhelm, C.R.2
Gage, K.L.3
Fabrizio, M.C.4
Wagner, W.R.5
-
2
-
-
0035985026
-
Predicting membrane oxygenator pressure drop using computational fluid dynamics
-
Gage KL, Gartner MJ, Burgreen GW and Wanger WR: Predicting membrane oxygenator pressure drop using computational fluid dynamics. Artif Organs (2002) 26: 600-607.
-
(2002)
Artif Organs
, vol.26
, pp. 600-607
-
-
Gage, K.L.1
Gartner, M.J.2
Burgreen, G.W.3
Wanger, W.R.4
-
3
-
-
33646796929
-
Development of a prototype of implantable artificial lung
-
Kinoshita T, Ichiba S, Aoe M, Shimizu N, Taga I, Funakubo A, Fukui Y and Sakai K: Development of a prototype of implantable artificial lung. ASAIO J (2001) 47: 104.
-
(2001)
ASAIO J
, vol.47
, pp. 104
-
-
Kinoshita, T.1
Ichiba, S.2
Aoe, M.3
Shimizu, N.4
Taga, I.5
Funakubo, A.6
Fukui, Y.7
Sakai, K.8
-
4
-
-
0042308602
-
Flow vectorial analysis in an artificial implantable lung
-
Funakubo A, Taga I, McGillicuddy JB, Fukui Y, Hischl RB and Bartlett RH: Flow vectorial analysis in an artificial implantable lung. ASAIO J (2003) 49: 383-387.
-
(2003)
ASAIO J
, vol.49
, pp. 383-387
-
-
Funakubo, A.1
Taga, I.2
McGillicuddy, J.B.3
Fukui, Y.4
Hischl, R.B.5
Bartlett, R.H.6
-
5
-
-
0041905222
-
Studies of gas and electrode equilibria in blood. XV. Line charts for graphic calculations by the Henderson-Hasselbalch equation, and for calculating plasma carbon dioxide content from whole blood content
-
Van Slyke, D.D. and Sendroy J: Studies of gas and electrode equilibria in blood. XV. Line charts for graphic calculations by the Henderson-Hasselbalch equation, and for calculating plasma carbon dioxide content from whole blood content. J Biol Chem (1928) 79: 781-798.
-
(1928)
J Biol Chem
, vol.79
, pp. 781-798
-
-
Van Slyke, D.D.1
Sendroy, J.2
-
6
-
-
0035783601
-
An artificial lung reduces pulmonary impedance and improves right ventricular efficiency in pulmonary hypertension
-
Haft JW, Montoya P, Alnajjar O, Posner SR, Bull JL, Iannettoni MD, Bartlett RH and Hirschl RB. An artificial lung reduces pulmonary impedance and improves right ventricular efficiency in pulmonary hypertension. J Thorac Cardiovasc Surg (2001) 122: 1094-1100.
-
(2001)
J Thorac Cardiovasc Surg
, vol.122
, pp. 1094-1100
-
-
Haft, J.W.1
Montoya, P.2
Alnajjar, O.3
Posner, S.R.4
Bull, J.L.5
Iannettoni, M.D.6
Bartlett, R.H.7
Hirschl, R.B.8
-
7
-
-
0034847756
-
Improved right heart function with a compliant inflow artificial lung in series with the pulmonary circulation
-
Lick SD, Zwischenberger JB, Wang D, Deyo DJ, Alpard SK and Chambers SD: Improved right heart function with a compliant inflow artificial lung in series with the pulmonary circulation. Ann Thorac Surg (2001) 72: 899-904.
-
(2001)
Ann Thorac Surg
, vol.72
, pp. 899-904
-
-
Lick, S.D.1
Zwischenberger, J.B.2
Wang, D.3
Deyo, D.J.4
Alpard, S.K.5
Chambers, S.D.6
-
8
-
-
0022209851
-
Compact cross-flow tubular oxygenators
-
Mockros LF and Leonard RJ : Compact cross-flow tubular oxygenators. Trans ASAIO (1985) 31: 628-632.
-
(1985)
Trans ASAIO
, vol.31
, pp. 628-632
-
-
Mockros, L.F.1
Leonard, R.J.2
-
9
-
-
0033968310
-
Hemodynamic effects of attachment modes and device design of a thoracic artificial lung
-
Boschetti F, Perlman CE, Cook KE and Mockros LF: Hemodynamic effects of attachment modes and device design of a thoracic artificial lung. ASAIO J (2000) 46: 42-48.
-
(2000)
ASAIO J
, vol.46
, pp. 42-48
-
-
Boschetti, F.1
Perlman, C.E.2
Cook, K.E.3
Mockros, L.F.4
|