메뉴 건너뛰기




Volumn 31, Issue 9, 2006, Pages 967-971

A biomechanical assessment of infra-laminar hooks as an alternative to supra-laminar hooks in thoracolumbar fixation

Author keywords

Biomechanics; Hook; Pedicle screw; Posterior fixation; Thoracolumbar junction

Indexed keywords

ARTICLE; BIOMECHANICS; HUMAN; HUMAN TISSUE; PEDICLE SCREW; PRIORITY JOURNAL; SPINE STABILIZATION; STANDARDIZATION; STATISTICAL ANALYSIS; THORACOLUMBAR SPINE; VERTEBRA; BONE SCREW; ELASTICITY; EQUIPMENT; INSTRUMENTATION; LUMBAR VERTEBRA; MECHANICAL STRESS; METHODOLOGY; PROSTHESIS FAILURE; SPINE FUSION;

EID: 33646710387     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/01.brs.0000214932.49027.6a     Document Type: Article
Times cited : (17)

References (22)
  • 1
    • 0031427801 scopus 로고    scopus 로고
    • Internal fixation in the osteoporotic spine
    • Hu SS. Internal fixation in the osteoporotic spine. Spine 1997;22(suppl): 43-8.
    • (1997) Spine , vol.22 , Issue.SUPPL. , pp. 43-48
    • Hu, S.S.1
  • 2
    • 6644226483 scopus 로고    scopus 로고
    • Influence of bone mineral density on pedicle screw fixation: A study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients
    • Okuyama K, Abe E, Suzuki T, et al. Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients. Spine J 2001;1:402-7.
    • (2001) Spine J , vol.1 , pp. 402-407
    • Okuyama, K.1    Abe, E.2    Suzuki, T.3
  • 3
    • 0032143033 scopus 로고    scopus 로고
    • Revision of failed pedicle screws using hydroxyapatite cement: A biomechanical analysis
    • Yerby SA, Toh E, McLain RF. Revision of failed pedicle screws using hydroxyapatite cement: a biomechanical analysis. Spine 1998;23: 1657-61.
    • (1998) Spine , vol.23 , pp. 1657-1661
    • Yerby, S.A.1    Toh, E.2    McLain, R.F.3
  • 4
    • 0034528813 scopus 로고    scopus 로고
    • Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities: An innovative technique
    • Wuisman PI, Van Dijk M, Staal H, et al. Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities: an innovative technique. Eur Spine J 2000;9:528-33.
    • (2000) Eur Spine J , vol.9 , pp. 528-533
    • Wuisman, P.I.1    Van Dijk, M.2    Staal, H.3
  • 5
    • 0031431778 scopus 로고    scopus 로고
    • Future directions: Augmentation of osteoporotic vertebral bodies
    • Bostrom MP, Lane JM. Future directions: augmentation of osteoporotic vertebral bodies. Spine 1997;22(suppl):38-42.
    • (1997) Spine , vol.22 , Issue.SUPPL. , pp. 38-42
    • Bostrom, M.P.1    Lane, J.M.2
  • 6
    • 0028314201 scopus 로고
    • Repair of failed transpedicle screw fixation: A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction
    • Pfeifer BA, Krag MH, Johnson C. Repair of failed transpedicle screw fixation: a biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction. Spine 1994;19:350-3.
    • (1994) Spine , vol.19 , pp. 350-353
    • Pfeifer, B.A.1    Krag, M.H.2    Johnson, C.3
  • 7
    • 0026445667 scopus 로고
    • Anatomic and technical considerations of pedicle screw fixation
    • Weinstein JN, Rydevik BL, Rauschning W. Anatomic and technical considerations of pedicle screw fixation. Clin Orthop 1992:34-46.
    • (1992) Clin Orthop , pp. 34-46
    • Weinstein, J.N.1    Rydevik, B.L.2    Rauschning, W.3
  • 8
    • 0028034777 scopus 로고
    • Effects of bone mineral density on pedicle screw fixation
    • Halvorson TL, Kelley LA, Thomas KA, et al. Effects of bone mineral density on pedicle screw fixation. Spine 1994;19:2415-20.
    • (1994) Spine , vol.19 , pp. 2415-2420
    • Halvorson, T.L.1    Kelley, L.A.2    Thomas, K.A.3
  • 9
    • 0030023310 scopus 로고    scopus 로고
    • The role of pediculolaminar fixation in compromised pedicle bone
    • Hilibrand AS, Moore DC, Graziano GP. The role of pediculolaminar fixation in compromised pedicle bone. Spine 1996;21:445-51.
    • (1996) Spine , vol.21 , pp. 445-451
    • Hilibrand, A.S.1    Moore, D.C.2    Graziano, G.P.3
  • 10
    • 0030911539 scopus 로고    scopus 로고
    • An experimental study of a combination method using a pedicle screw and laminar hook for the osteoporotic spine
    • Hasegawa K, Takahashi HE, Uchiyama S, et al. An experimental study of a combination method using a pedicle screw and laminar hook for the osteoporotic spine. Spine 1997;22:958-62; discussion 963.
    • (1997) Spine , vol.22 , pp. 958-962
    • Hasegawa, K.1    Takahashi, H.E.2    Uchiyama, S.3
  • 11
    • 4043151569 scopus 로고    scopus 로고
    • Pedicle screw motion in the osteoporotic spine after augmentation with laminar hooks, sublaminar wires, or calcium phosphate cement: A comparative analysis
    • Tan JS, Kwon BK, Dvorak MF, et al. Pedicle screw motion in the osteoporotic spine after augmentation with laminar hooks, sublaminar wires, or calcium phosphate cement: a comparative analysis. Spine 2004;29:1723-30.
    • (2004) Spine , vol.29 , pp. 1723-1730
    • Tan, J.S.1    Kwon, B.K.2    Dvorak, M.F.3
  • 12
    • 0030038215 scopus 로고    scopus 로고
    • Short-segment pedicle instrumentation: Biomechanical analysis of supplemental hook fixation
    • Chiba M, McLain RF, Yerby SA, et al. Short-segment pedicle instrumentation: biomechanical analysis of supplemental hook fixation. Spine 1996;21: 288-94.
    • (1996) Spine , vol.21 , pp. 288-294
    • Chiba, M.1    McLain, R.F.2    Yerby, S.A.3
  • 13
    • 0030476303 scopus 로고    scopus 로고
    • Transfacet screws with lumbar interbody reconstruction: Biomechanical study of motion segment stiffness
    • Volkman T, Horton WC, Hutton WC. Transfacet screws with lumbar interbody reconstruction: biomechanical study of motion segment stiffness. J Spinal Disord 1996;9:425-32.
    • (1996) J Spinal Disord , vol.9 , pp. 425-432
    • Volkman, T.1    Horton, W.C.2    Hutton, W.C.3
  • 14
    • 0025675449 scopus 로고
    • Biomechanical evaluation of lumbar spinal instability after graded facetectomies
    • Abumi K, Panjabi MM, Kramer KM, et al. Biomechanical evaluation of lumbar spinal instability after graded facetectomies. Spine 1990;15:1142-7.
    • (1990) Spine , vol.15 , pp. 1142-1147
    • Abumi, K.1    Panjabi, M.M.2    Kramer, K.M.3
  • 15
    • 0028306362 scopus 로고
    • Assessment of fracture risk and its application to screening for postmenopausal osteoporosis: Report of a WHO Study Group
    • WHO. Assessment of fracture risk and its application to screening for postmenopausal osteoporosis: Report of a WHO Study Group. World Health Organ Tech Rep Ser 1994;843:1-129.
    • (1994) World Health Organ Tech Rep Ser , vol.843 , pp. 1-129
  • 16
    • 0026439770 scopus 로고
    • Transpedicular screw-rod fixation of the lumbar spine: Operative technique and outcome in 104 cases
    • Dickman CA, Fessler RG, MacMillan M, et al. Transpedicular screw-rod fixation of the lumbar spine: operative technique and outcome in 104 cases. J Neurosurg 1992;77:860-70.
    • (1992) J Neurosurg , vol.77 , pp. 860-870
    • Dickman, C.A.1    Fessler, R.G.2    MacMillan, M.3
  • 17
    • 0033998139 scopus 로고    scopus 로고
    • Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion
    • Okuyama K, Abe E, Suzuki T, et al. Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion. Spine 2000;25:858-64.
    • (2000) Spine , vol.25 , pp. 858-864
    • Okuyama, K.1    Abe, E.2    Suzuki, T.3
  • 18
    • 0025903474 scopus 로고
    • Importance of bone mineral density in instrumented spine fusions
    • Wittenberg RH, Shea M, Swartz DE, et al. Importance of bone mineral density in instrumented spine fusions. Spine 1991;16:647-52.
    • (1991) Spine , vol.16 , pp. 647-652
    • Wittenberg, R.H.1    Shea, M.2    Swartz, D.E.3
  • 19
    • 0025641159 scopus 로고
    • Problems and solutions of pedicle screw plate fixation of lumbar spine
    • Matsuzaki H, Tokuhashi Y, Matsumoto F, et al. Problems and solutions of pedicle screw plate fixation of lumbar spine. Spine 1990;15:1159-65.
    • (1990) Spine , vol.15 , pp. 1159-1165
    • Matsuzaki, H.1    Tokuhashi, Y.2    Matsumoto, F.3
  • 20
    • 0027509721 scopus 로고
    • Early failure of short-segment pedicle instrumentation for thoracolumbar fractures: A preliminary report
    • McLain RF, Sparling E, Benson DR. Early failure of short-segment pedicle instrumentation for thoracolumbar fractures: a preliminary report. J Bone Joint Surg Am 1993;75:162-7.
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 162-167
    • McLain, R.F.1    Sparling, E.2    Benson, D.R.3
  • 21
    • 0025988460 scopus 로고
    • An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine
    • Soshi S, Shiba R, Kondo H, et al. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 1991; 16:1335-41.
    • (1991) Spine , vol.16 , pp. 1335-1341
    • Soshi, S.1    Shiba, R.2    Kondo, H.3
  • 22
    • 0030882430 scopus 로고    scopus 로고
    • The mechanical role of laminar hook protection of pedicle screws at the caudal end vertebra
    • Margulies JY, Casar RS, Caruso SA, et al. The mechanical role of laminar hook protection of pedicle screws at the caudal end vertebra. Eur Spine J 1997;6:245-8.
    • (1997) Eur Spine J , vol.6 , pp. 245-248
    • Margulies, J.Y.1    Casar, R.S.2    Caruso, S.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.