메뉴 건너뛰기




Volumn 3, Issue 7, 2006, Pages 351-357

Comparison of sampling and analytical methods used during the preparation of methyl methacrylate bone cements

Author keywords

Bone cement; Detector tubes; Gas chromatography; Method comparison; Methyl methacrylate; Photoacoustic infrared spectrometry

Indexed keywords

BONE CEMENT; METHACRYLIC ACID METHYL ESTER; SORBENT;

EID: 33646707508     PISSN: 15459624     EISSN: 15459632     Source Type: Journal    
DOI: 10.1080/15459620600732811     Document Type: Article
Times cited : (5)

References (10)
  • 1
    • 19544364281 scopus 로고
    • Air concentrations of methyl methacrylate monomer after mixing different acrylic bone cements
    • Darre, E.D., P. Vedel, and J. S. Jensen: Air concentrations of methyl methacrylate monomer after mixing different acrylic bone cements. Adv. Orthop. Surg. 10:258-259 (1987).
    • (1987) Adv. Orthop. Surg. , vol.10 , pp. 258-259
    • Darre, E.D.1    Vedel, P.2    Jensen, J.S.3
  • 3
    • 0026744096 scopus 로고
    • Breathing zone concentrations of methyl methacylate monomer during joint replacement operations
    • Darre, E.D., L.G. Jorgensen, P. Vedel, and J.S. Jensen: Breathing zone concentrations of methyl methacylate monomer during joint replacement operations. Pharm. Toxicol. 17:198-200 (1992).
    • (1992) Pharm. Toxicol. , vol.17 , pp. 198-200
    • Darre, E.D.1    Jorgensen, L.G.2    Vedel, P.3    Jensen, J.S.4
  • 4
    • 19544364281 scopus 로고
    • Air concentrations of methyl methacrylate monomer after mixing different acrylic bone cements
    • Darre, E.D., P. Vedel, and J.S. Jensen: Air concentrations of methyl methacrylate monomer after mixing different acrylic bone cements. Adv. Orthop. Surg. 10:258-259 (1987).
    • (1987) Adv. Orthop. Surg. , vol.10 , pp. 258-259
    • Darre, E.D.1    Vedel, P.2    Jensen, J.S.3
  • 5
    • 7044266763 scopus 로고
    • Efficiency of bone cement mixing systems - A gas chromatographic study
    • Darre, E.D., P. Vedel, and J.S. Jensen: Efficiency of bone cement mixing systems - A gas chromatographic study. Adv. Orthop. Surg. 77:106-108 (1988).
    • (1988) Adv. Orthop. Surg. , vol.77 , pp. 106-108
    • Darre, E.D.1    Vedel, P.2    Jensen, J.S.3
  • 6
    • 0028364107 scopus 로고
    • Analysis of fume emission from ultrasonic removal of methyl methacrylate cement in revision hip surgery
    • Cautilli, G.P., and W.J. Hozack: Analysis of fume emission from ultrasonic removal of methyl methacrylate cement in revision hip surgery. J. Arthroplasty 9:305-306 (1994).
    • (1994) J. Arthroplasty , vol.9 , pp. 305-306
    • Cautilli, G.P.1    Hozack, W.J.2
  • 8
    • 84875659944 scopus 로고
    • Method 2537: Methyl methacrylate
    • P.C. Schlecht, P.C. and P.F. O'Connor (eds.). Publication No. 94-113. Cincinnati, Ohio, NIOSH
    • National Institute for Occupational Safety and Health (NIOSH): Method 2537: Methyl methacrylate. In NIOSH Manual of Analytical Methods (NMAM), 4th ed. P.C. Schlecht, P.C. and P.F. O'Connor (eds.). Publication No. 94-113. Cincinnati, Ohio, NIOSH, 1994.
    • (1994) NIOSH Manual of Analytical Methods (NMAM), 4th Ed.
  • 10
    • 0025261744 scopus 로고
    • Estimation of average concentration in the presence of nondetectable values
    • Hornung, R.W., and L.D. Reed: Estimation of average concentration in the presence of nondetectable values. Appl. Occup. Environ. Hyg. 5:46-51 (1990).
    • (1990) Appl. Occup. Environ. Hyg. , vol.5 , pp. 46-51
    • Hornung, R.W.1    Reed, L.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.