메뉴 건너뛰기




Volumn 3565, Issue , 2005, Pages 222-233

Tissue perfusion diagnostic classification using a spatio-temporal analysis of contrast ultrasound image sequences

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; ECHOCARDIOGRAPHY; TISSUE; ULTRASONICS;

EID: 33646687137     PISSN: 03029743     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/11505730_19     Document Type: Conference Paper
Times cited : (6)

References (13)
  • 2
    • 0034233024 scopus 로고    scopus 로고
    • Ultrasound contrast imaging: Current and new potential methods
    • Frinking, P.J.A., Bouakaz, A., Kirkhorn, J., et al.: Ultrasound Contrast Imaging: Current and new potential methods. Ultrasound Med. Biol. 26 (2000) 965-975
    • (2000) Ultrasound Med. Biol. , vol.26 , pp. 965-975
    • Frinking, P.J.A.1    Bouakaz, A.2    Kirkhorn, J.3
  • 3
    • 0031264509 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography
    • Kaul, S.: Myocardial contrast echocardiography. Curr. Probl. Cardiol. 22 (1997) 549-640
    • (1997) Curr. Probl. Cardiol. , vol.22 , pp. 549-640
    • Kaul, S.1
  • 4
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • Wei, K., Jayaweera A.R., Firoozan S., et al.: Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 98 (1998) 473-483
    • (1998) Circulation , vol.98 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3
  • 5
    • 0032480764 scopus 로고    scopus 로고
    • Assessment of transmural distribution of myocardial perfusion with contrast echocardiography
    • Linka, A., Sklenar, J., Wei, K., Jayaweera A.R., Kaul, S.: Assessment of transmural distribution of myocardial perfusion with contrast echocardiography. Circulation 98 (1998) 1912-1920
    • (1998) Circulation , vol.98 , pp. 1912-1920
    • Linka, A.1    Sklenar, J.2    Wei, K.3    Jayaweera, A.R.4    Kaul, S.5
  • 6
    • 20344391369 scopus 로고    scopus 로고
    • A spatio-temporal analysis of contrast ultrasound image sequence for assessment of tissue perfusion
    • Williams, Q., Noble, J.A.: A Spatio-Temporal Analysis of Contrast Ultrasound image sequence for assessment of Tissue Perfusion. Proceedings MICCAIII (2004) 899-906
    • (2004) Proceedings MICCAI , vol.2 , pp. 899-906
    • Williams, Q.1    Noble, J.A.2
  • 7
    • 0035296808 scopus 로고    scopus 로고
    • Extracting parametric images from dynamic contrast-enhanced MRI studies of the brain using factor
    • Martel, A.L., Moody, A.R., Allder, S.J., et al.: Extracting parametric images from dynamic contrast-enhanced MRI studies of the brain using factor. Medical Image Analysis 5 (2001) 29-39
    • (2001) Medical Image Analysis , vol.5 , pp. 29-39
    • Martel, A.L.1    Moody, A.R.2    Allder, S.J.3
  • 8
    • 0001964712 scopus 로고    scopus 로고
    • The use of PCA to smooth functional MR images
    • Oxford, July
    • Martel, A.L., Moody, A.R.: The use of PCA to smooth functional MR images. Proceedings MIUA, Oxford, July (1997) 13-16
    • (1997) Proceedings MIUA , pp. 13-16
    • Martel, A.L.1    Moody, A.R.2
  • 9
    • 4143138525 scopus 로고    scopus 로고
    • Absolute myocardial perfusion in canines measured by using dual bolus first-pass MR imaging
    • Christian, T.F., et al.: Absolute Myocardial Perfusion in canines measured by using dual bolus first-pass MR Imaging. Radiology (2004) 232-677
    • (2004) Radiology , pp. 232-677
    • Christian, T.F.1
  • 10
    • 0035856553 scopus 로고    scopus 로고
    • Limits of detection of regional differences in vasodilated now in viable myocardium by first-pass MR perfusion imaging
    • Klocke, F.J., Simonetti, O.P., Judd, R.M., et al.: Limits of detection of regional differences in vasodilated now in viable myocardium by first-pass MR perfusion imaging. Circulation (2001) 2412
    • (2001) Circulation , pp. 2412
    • Klocke, F.J.1    Simonetti, O.P.2    Judd, R.M.3
  • 11
    • 0036194688 scopus 로고    scopus 로고
    • Automated, non-rigid alignment of clinical myocardial contrast echocardiographic image sequences: Comparison with manual alignment
    • Noble, J.A., Dawson, D., Lindner, J., Sklenar, J., Kaul, S.: Automated, non-rigid alignment of clinical myocardial contrast echocardiographic image sequences: comparison with manual alignment. Ultrasound in Medicine and Biology 28(1) (2002) 115-123
    • (2002) Ultrasound in Medicine and Biology , vol.28 , Issue.1 , pp. 115-123
    • Noble, J.A.1    Dawson, D.2    Lindner, J.3    Sklenar, J.4    Kaul, S.5
  • 13
    • 0024723470 scopus 로고
    • Recommendations for quantitation of the left ventricle by two-dimensional echocardiography
    • Schiller, N., Shah, P., Crawford, M., et al.: Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. Journal of the American Society of Echocardiography 5 (1989) 358-367
    • (1989) Journal of the American Society of Echocardiography , vol.5 , pp. 358-367
    • Schiller, N.1    Shah, P.2    Crawford, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.