-
1
-
-
33645368890
-
Dialyzer reuse - part I: historical perspective
-
Twardowski ZJ: Dialyzer reuse - part I: historical perspective. Semin Dial 19: 41 53, 2006
-
(2006)
Semin Dial
, vol.19
, pp. 41-53
-
-
Twardowski, Z.J.1
-
2
-
-
0019335227
-
DA: New-dialyzer syndrome
-
Ogden.
-
Ogden DA: New-dialyzer syndrome. N Engl J Med 302: 1962 1963, 1980
-
(1980)
N Engl J Med
, vol.302
, pp. 1962-1963
-
-
-
3
-
-
0020409069
-
Severe reactions to Cuprophan capillary dialyzers
-
Popli S, Ing TS, Daugirdas JT, Kheirbek AO, Viol GW, Vilbar RM, Gandhi VC: Severe reactions to Cuprophan capillary dialyzers. Artif Organs 6: 312 315, 1982
-
(1982)
Artif Organs
, vol.6
, pp. 312-315
-
-
Popli, S.1
Ing, T.S.2
Daugirdas, J.T.3
Kheirbek, A.O.4
Viol, G.W.5
Vilbar, R.M.6
Gandhi, V.C.7
-
4
-
-
0025856348
-
Dialyser reprocessing with Renalin®
-
Fleming SJ, Foreman K, Shanley K, Mihrshahi R, Siskind V: Dialyser reprocessing with Renalin®. Am J Nephrol 11: 27 31, 1991
-
(1991)
Am J Nephrol
, vol.11
, pp. 27-31
-
-
Fleming, S.J.1
Foreman, K.2
Shanley, K.3
Mihrshahi, R.4
Siskind, V.5
-
5
-
-
0014429327
-
Profound neutropenia during the early phase of hemodialysis
-
Kaplow LS, Goffinet JA: Profound neutropenia during the early phase of hemodialysis. JAMA 203: 1135 1137, 1968
-
(1968)
JAMA
, vol.203
, pp. 1135-1137
-
-
Kaplow, L.S.1
Goffinet, J.A.2
-
6
-
-
0014452680
-
Leukocyte dynamics with three types of hemodialyzers
-
Gral T, Schroth P, De Palma JR, Gordon A: Leukocyte dynamics with three types of hemodialyzers. Trans Am Soc Artif Intern Organs 15: 45 49, 1969
-
(1969)
Trans Am Soc Artif Intern Organs
, vol.15
, pp. 45-49
-
-
Gral, T.1
Schroth, P.2
De Palma, J.R.3
Gordon, A.4
-
7
-
-
0014847273
-
Pulmonary bed sequestration of neutrophils during hemodialysis
-
Toren M, Goffinet JA, Kaplow LS: Pulmonary bed sequestration of neutrophils during hemodialysis. Blood 36: 337 340, 1970
-
(1970)
Blood
, vol.36
, pp. 337-340
-
-
Toren, M.1
Goffinet, J.A.2
Kaplow, L.S.3
-
8
-
-
0017579231
-
Complement and leukocyte-mediated pulmonary dysfunction in hemodialysis
-
Craddock PR, Fehr J, Brigham KL, Kronenberg RS, Jacob HS: Complement and leukocyte-mediated pulmonary dysfunction in hemodialysis. N Engl J Med 296: 769 774, 1977
-
(1977)
N Engl J Med
, vol.296
, pp. 769-774
-
-
Craddock, P.R.1
Fehr, J.2
Brigham, K.L.3
Kronenberg, R.S.4
Jacob, H.S.5
-
9
-
-
0017413401
-
Hemodialysis leukopenia. Pulmonary vascular leukostasis resulting from complement activation by dialyzer cellophane membranes
-
Craddock PR, Fehr J, Dalmasso AP, Brighan KL, Jacob HS: Hemodialysis leukopenia. Pulmonary vascular leukostasis resulting from complement activation by dialyzer cellophane membranes. J Clin Invest 59: 879 888, 1977
-
(1977)
J Clin Invest
, vol.59
, pp. 879-888
-
-
Craddock, P.R.1
Fehr, J.2
Dalmasso, A.P.3
Brighan, K.L.4
Jacob, H.S.5
-
10
-
-
0019271189
-
Effect of dialyzer reuse on leukopenia, hypoxemia and total hemolytic complement system
-
Hakim RM, Lowrie EG: Effect of dialyzer reuse on leukopenia, hypoxemia and total hemolytic complement system. Trans Am Soc Artif Intern Organs 26: 159 164, 1980
-
(1980)
Trans Am Soc Artif Intern Organs
, vol.26
, pp. 159-164
-
-
Hakim, R.M.1
Lowrie, E.G.2
-
11
-
-
0019940662
-
Hemodialysis-associated neutropenia and hypoxemia: the effect of dialyzer membrane materials
-
Hakim RM, Lowrie EG: Hemodialysis-associated neutropenia and hypoxemia: the effect of dialyzer membrane materials. Nephron 32: 32 39, 1982
-
(1982)
Nephron
, vol.32
, pp. 32-39
-
-
Hakim, R.M.1
Lowrie, E.G.2
-
12
-
-
33646682951
-
2-Chloroethanol as a toxic residue in dialysis supplies sterilized with ethylene oxide
-
Gutch CF, Eskelson CD, Ziegler E, Odgen DA: 2-Chloroethanol as a toxic residue in dialysis supplies sterilized with ethylene oxide. Dial Transplant 5: 21 25, 1976
-
(1976)
Dial Transplant
, vol.5
, pp. 21-25
-
-
Gutch, C.F.1
Eskelson, C.D.2
Ziegler, E.3
Odgen, D.A.4
-
13
-
-
0016429223
-
Anaphylaxis from the product(s) of ethylene oxide gas
-
Poothullil J, Shimizu A, Day RP, Dolovich J: Anaphylaxis from the product(s) of ethylene oxide gas. Ann Intern Med 82: 58 60, 1975
-
(1975)
Ann Intern Med
, vol.82
, pp. 58-60
-
-
Poothullil, J.1
Shimizu, A.2
Day, R.P.3
Dolovich, J.4
-
14
-
-
0021967824
-
IgE against ethylene oxide-altered human serum albumin in patients with anaphylactic reactions to dialysis
-
Grammer LC, Paterson BF, Roxe D, Daugirdas JT, Ing TS, Ivanovich PT, Brown CB, Nicholls AJ, Patterson R: IgE against ethylene oxide-altered human serum albumin in patients with anaphylactic reactions to dialysis. J Allergy Clin Immunol 76: 511 514, 1985
-
(1985)
J Allergy Clin Immunol
, vol.76
, pp. 511-514
-
-
Grammer, L.C.1
Paterson, B.F.2
Roxe, D.3
Daugirdas, J.T.4
Ing, T.S.5
Ivanovich, P.T.6
Brown, C.B.7
Nicholls, A.J.8
Patterson, R.9
-
15
-
-
0021703583
-
Migration of acetylated hemicellulose from capillary hemodialyzer to blood, causing scleritis and/or iritis
-
Oba T, Tsuji K, Nakamura A, Shintani H, Mizumachi S, Kikuchi H, Kaniwa M, Kojima S, Kanohta K, Kawasaki Y, Furuya T, Matsumoto K, Tobe M: Migration of acetylated hemicellulose from capillary hemodialyzer to blood, causing scleritis and/or iritis. Artif Organs 8: 429 435, 1984
-
(1984)
Artif Organs
, vol.8
, pp. 429-435
-
-
Oba, T.1
Tsuji, K.2
Nakamura, A.3
Shintani, H.4
Mizumachi, S.5
Kikuchi, H.6
Kaniwa, M.7
Kojima, S.8
Kanohta, K.9
Kawasaki, Y.10
Furuya, T.11
Matsumoto, K.12
Tobe, M.13
-
16
-
-
0034716715
-
Acute onset of decreased vision and hearing traced to hemodialysis treatment with aged dialyzers
-
Hutter JC, Kuehnert MJ, Wallis RR, Lucas AD, Sen S, Jarvis WR: Acute onset of decreased vision and hearing traced to hemodialysis treatment with aged dialyzers. JAMA 283: 2128 2134, 2000
-
(2000)
JAMA
, vol.283
, pp. 2128-2134
-
-
Hutter, J.C.1
Kuehnert, M.J.2
Wallis, R.R.3
Lucas, A.D.4
Sen, S.5
Jarvis, W.R.6
-
17
-
-
0035811272
-
Effect of cellulose acetate materials on the oxidative burst of human neutrophils
-
Moore MA, Kaplan DS, Picciolo GL, Wallis RR, Kowolik MJ: Effect of cellulose acetate materials on the oxidative burst of human neutrophils. J Biomed Mater Res 55: 257 265, 2001
-
(2001)
J Biomed Mater Res
, vol.55
, pp. 257-265
-
-
Moore, M.A.1
Kaplan, D.S.2
Picciolo, G.L.3
Wallis, R.R.4
Kowolik, M.J.5
-
18
-
-
0034834572
-
Red eye syndrome: clinical and experimental experience in a new aspect of diffuse eosinophilic infiltration?
-
Averbukh Z, Modai D, Sandbank J, Berman S, Cohn M, Galperin E, Cohen N, Dishi V, Weissgarten J: Red eye syndrome: clinical and experimental experience in a new aspect of diffuse eosinophilic infiltration? Artif Organs 25: 437 440, 2001
-
(2001)
Artif Organs
, vol.25
, pp. 437-440
-
-
Averbukh, Z.1
Modai, D.2
Sandbank, J.3
Berman, S.4
Cohn, M.5
Galperin, E.6
Cohen, N.7
Dishi, V.8
Weissgarten, J.9
-
19
-
-
0036226847
-
Performance liquid test as a cause for sudden deaths of dialysis patients: perfluorohydrocarbon, a previously unrecognized hazard for dialysis patients
-
Canaud B, European Experts Panel: Performance liquid test as a cause for sudden deaths of dialysis patients: perfluorohydrocarbon, a previously unrecognized hazard for dialysis patients. Nephrol Dial Transplant 17: 545 548, 2002
-
(2002)
Nephrol Dial Transplant
, vol.17
, pp. 545-548
-
-
Canaud, B.1
-
20
-
-
0036739202
-
Dialyzer repair: a disastrous exercise in cost effectiveness
-
Shaldon S, Koch KM: Dialyzer repair: a disastrous exercise in cost effectiveness. ASAIO J 48: 453 454, 2002
-
(2002)
ASAIO J
, vol.48
, pp. 453-454
-
-
Shaldon, S.1
Koch, K.M.2
-
21
-
-
9844223842
-
22 years' experience with reuse
-
Shaldon S: 22 years' experience with reuse. Dial Transplant 11: 569 570, 1982
-
(1982)
Dial Transplant
, vol.11
, pp. 569-570
-
-
Shaldon, S.1
-
22
-
-
0023149910
-
Exposure of patients to phthalates from polyvinyl chloride tubes and bags during dialysis
-
Nässberger L, Arbin A, Östelius J: Exposure of patients to phthalates from polyvinyl chloride tubes and bags during dialysis. Nephron 45: 286 290, 1987
-
(1987)
Nephron
, vol.45
, pp. 286-290
-
-
Nässberger, L.1
Arbin, A.2
Östelius, J.3
-
23
-
-
0021248347
-
Phthalate esters and their effect on the liver
-
Ganning AE, Brunk U, Dallner G: Phthalate esters and their effect on the liver. Hepatology 4: 541 547, 1984
-
(1984)
Hepatology
, vol.4
, pp. 541-547
-
-
Ganning, A.E.1
Brunk, U.2
Dallner, G.3
-
24
-
-
0037977838
-
Pediatric exposure and potential toxicity of phthalate plasticizers
-
Shea KM, American Academy of Pediatrics Committee on Environmental Health: Pediatric exposure and potential toxicity of phthalate plasticizers. Pediatrics 111 6 pt 1 1467 1474, 2003
-
(2003)
Pediatrics
, vol.111
, Issue.61
, pp. 1467-1474
-
-
Shea, K.M.1
-
25
-
-
0030836558
-
The technology of dialyzer reuse
-
Schoenfeld PY: The technology of dialyzer reuse. Semin Nephrol 17: 321 330, 1997
-
(1997)
Semin Nephrol
, vol.17
, pp. 321-330
-
-
Schoenfeld, P.Y.1
-
26
-
-
33645377864
-
Renalin: qualification as a dialyzer sterilant
-
In: Vol. 3, Arlington, VA: Association for the Advancement of Medical Instrumentation
-
Fischbach LJ: Renalin: qualification as a dialyzer sterilant. In: AAMI Standards and Recommended Practices. Vol. 3, Dialysis. Arlington, VA: Association for the Advancement of Medical Instrumentation, 1993: 195 199
-
(1993)
AAMI Standards and Recommended Practices. Vol. 3, Dialysis
, vol.3
, pp. 195-199
-
-
Fischbach, L.J.1
-
27
-
-
0024457535
-
Measurement of specific IgE antibodies in individuals exposed to formaldehyde
-
Kramps JA, Peltenburg LTC, Kerklaan PR, Spieksma FT, Valentijn RM, Dijkman JH: Measurement of specific IgE antibodies in individuals exposed to formaldehyde. Clin Exp Allergy 19: 509 514, 1989
-
(1989)
Clin Exp Allergy
, vol.19
, pp. 509-514
-
-
Kramps, J.A.1
Peltenburg, L.T.C.2
Kerklaan, P.R.3
Spieksma, F.T.4
Valentijn, R.M.5
Dijkman, J.H.6
-
28
-
-
0031813167
-
Occupational asthma due to glutaraldehyde
-
Di Stefano F, Siriruttanapruk S, McCoach JS, Burge PS: Occupational asthma due to glutaraldehyde. Monaldi Arch Chest Dis 53: 50 55, 1998
-
(1998)
Monaldi Arch Chest Dis
, vol.53
, pp. 50-55
-
-
Di Stefano, F.1
Siriruttanapruk, S.2
McCoach, J.S.3
Burge, P.S.4
-
29
-
-
0024976775
-
Acute allergic reactions associated with reprocessed dialyzers - Virginia, 1989
-
Miller GB Jr., Sikes RK, US Centers for Disease Control: Acute allergic reactions associated with reprocessed dialyzers - Virginia, 1989. MMWR 38: 873 874, 1989
-
(1989)
MMWR
, vol.38
, pp. 873-874
-
-
Miller Jr., G.B.1
Sikes, R.K.2
-
30
-
-
0026419542
-
Update: acute allergic reactions associated with reprocessed dialyzers - United States, 1989-1990
-
Miller GB, Wilber J, US Centers for Disease Control: Update: acute allergic reactions associated with reprocessed dialyzers - United States, 1989-1990. MMWR 40: 147 153, 1991
-
(1991)
MMWR
, vol.40
, pp. 147-153
-
-
Miller, G.B.1
Wilber, J.2
-
31
-
-
0026793330
-
Anaphylactoid reactions associated with reuse of hollow-fiber hemodialyzers and ACE inhibitors
-
Pegues DA, Beck-Sague CM, Woollen SW, Greenspan B, Burns SM, Bland LA, Arduino MJ, Favero MS, Mackow RC, Jarvis WR: Anaphylactoid reactions associated with reuse of hollow-fiber hemodialyzers and ACE inhibitors. Kidney Int 42: 1232 1237, 1992
-
(1992)
Kidney Int
, vol.42
, pp. 1232-1237
-
-
Pegues, D.A.1
Beck-Sague, C.M.2
Woollen, S.W.3
Greenspan, B.4
Burns, S.M.5
Bland, L.A.6
Arduino, M.J.7
Favero, M.S.8
Mackow, R.C.9
Jarvis, W.R.10
-
32
-
-
0019470794
-
Residual formaldehyde in dialyzers: quantity, location, and the effect of different methods of rinsing
-
Lewis KJ, Ward MK, Kerr DNS: Residual formaldehyde in dialyzers: quantity, location, and the effect of different methods of rinsing. Artif Organs 5: 269 277, 1981
-
(1981)
Artif Organs
, vol.5
, pp. 269-277
-
-
Lewis, K.J.1
Ward, M.K.2
Kerr, D.N.S.3
-
33
-
-
0029087366
-
Rinsing time and disinfectant release of reused dialyzers: comparison of formaldehyde, hypochlorite, Warexin, and Renalin
-
Stragier A, Wenderickx D, Jadoul M: Rinsing time and disinfectant release of reused dialyzers: comparison of formaldehyde, hypochlorite, Warexin, and Renalin. Am J Kidney Dis 26: 549 553, 1995
-
(1995)
Am J Kidney Dis
, vol.26
, pp. 549-553
-
-
Stragier, A.1
Wenderickx, D.2
Jadoul, M.3
-
34
-
-
0034509864
-
The use of electrolyzed solutions for the cleaning and disinfecting of dialyzers
-
Tanaka N, Tanaka N, Fujisawa T, Daimon T, Fujiwara K, Yamamoto M, Abe T: The use of electrolyzed solutions for the cleaning and disinfecting of dialyzers. Artif Organs 24: 921 928, 2000
-
(2000)
Artif Organs
, vol.24
, pp. 921-928
-
-
Tanaka, N.1
Tanaka, N.2
Fujisawa, T.3
Daimon, T.4
Fujiwara, K.5
Yamamoto, M.6
Abe, T.7
-
35
-
-
84944420788
-
A technique for storage and multiple re-use of the Kiil dialyzer and blood tubing
-
Pollard TL, Barnett BMS, Eschbach JW, Scribner BH: A technique for storage and multiple re-use of the Kiil dialyzer and blood tubing. Trans ASAIO 13: 24 28, 1967
-
(1967)
Trans ASAIO
, vol.13
, pp. 24-28
-
-
Pollard, T.L.1
Barnett, B.M.S.2
Eschbach, J.W.3
Scribner, B.H.4
-
36
-
-
0018068180
-
Growth characteristics of atypical mycobacteria in water and their comparative resistance to disinfectants
-
Carson LA, Petersen NJ, Favero MS, Aguero SM: Growth characteristics of atypical mycobacteria in water and their comparative resistance to disinfectants. Appl Environ Microbiol 36: 839 846, 1978
-
(1978)
Appl Environ Microbiol
, vol.36
, pp. 839-846
-
-
Carson, L.A.1
Petersen, N.J.2
Favero, M.S.3
Aguero, S.M.4
-
37
-
-
0024215725
-
Prevalence of nontuberculous mycobacteria in water supplies of hemodialysis centers
-
Carson LA, Bland LA, Cusick LB, Favero MS, Bolan GA, Reingold AL, Good RC: Prevalence of nontuberculous mycobacteria in water supplies of hemodialysis centers. Appl Environ Microbiol 54: 3122 3125, 1988
-
(1988)
Appl Environ Microbiol
, vol.54
, pp. 3122-3125
-
-
Carson, L.A.1
Bland, L.A.2
Cusick, L.B.3
Favero, M.S.4
Bolan, G.A.5
Reingold, A.L.6
Good, R.C.7
-
38
-
-
0022337299
-
Formaldehyde kinetics and bacteriology in dialyzers
-
Hakim RM, Friedrich RA, Lowrie EG: Formaldehyde kinetics and bacteriology in dialyzers. Kidney Int 28: 936 943, 1985
-
(1985)
Kidney Int
, vol.28
, pp. 936-943
-
-
Hakim, R.M.1
Friedrich, R.A.2
Lowrie, E.G.3
-
39
-
-
0022358022
-
Infections with Mycobacterium chelonei in patients receiving dialysis and using processed hemodialyzers
-
Bolan G, Reingold AL, Carson LA, Silcox VA, Woodley CL, Hayes PS, Hightower AW, McFarland L, Brown JW III., Petersen NJ, Favero MS, Good RC: Infections with Mycobacterium chelonei in patients receiving dialysis and using processed hemodialyzers. J Infect Dis 152: 1013 1019, 1985
-
(1985)
J Infect Dis
, vol.152
, pp. 1013-1019
-
-
Bolan, G.1
Reingold, A.L.2
Carson, L.A.3
Silcox, V.A.4
Woodley, C.L.5
Hayes, P.S.6
Hightower, A.W.7
McFarland, L.8
Brown III, J.W.9
Petersen, N.J.10
Favero, M.S.11
Good, R.C.12
-
40
-
-
0025060721
-
Mycobacterium chelonae infection among patients receiving high-flux dialysis in a hemodialysis clinic in California
-
Lowry PW, Beck-Sague CM, Bland LA, Aguero SM, Arduino MJ, Minuth AN, Murray RA, Swenson JM, Jarvis WR: Mycobacterium chelonae infection among patients receiving high-flux dialysis in a hemodialysis clinic in California. J Infect Dis 161: 85 90, 1990
-
(1990)
J Infect Dis
, vol.161
, pp. 85-90
-
-
Lowry, P.W.1
Beck-Sague, C.M.2
Bland, L.A.3
Aguero, S.M.4
Arduino, M.J.5
Minuth, A.N.6
Murray, R.A.7
Swenson, J.M.8
Jarvis, W.R.9
-
41
-
-
0023802874
-
Pyrogenic reactions associated with the reuse of disposable hollow-fiber hemodialyzers
-
Gordon SM, Tipple M, Bland LA, Jarvis WR: Pyrogenic reactions associated with the reuse of disposable hollow-fiber hemodialyzers. JAMA 260: 2077 2081, 1988
-
(1988)
JAMA
, vol.260
, pp. 2077-2081
-
-
Gordon, S.M.1
Tipple, M.2
Bland, L.A.3
Jarvis, W.R.4
-
42
-
-
0026825470
-
Pyrogenic reactions in patients receiving conventional, high-efficiency, or high-flux hemodialysis treatments with bicarbonate dialysate containing high concentrations of bacteria and endotoxin
-
Gordon SM, Oettinger CW, Bland LA, Oliver JC, Arduino MJ, Aguero SM, McAllister SK, Favero MS, Jarvis WR: Pyrogenic reactions in patients receiving conventional, high-efficiency, or high-flux hemodialysis treatments with bicarbonate dialysate containing high concentrations of bacteria and endotoxin. J Am Soc Nephrol 2: 1436 1444, 1992
-
(1992)
J Am Soc Nephrol
, vol.2
, pp. 1436-1444
-
-
Gordon, S.M.1
Oettinger, C.W.2
Bland, L.A.3
Oliver, J.C.4
Arduino, M.J.5
Aguero, S.M.6
McAllister, S.K.7
Favero, M.S.8
Jarvis, W.R.9
-
43
-
-
0023890393
-
Backfiltration: a controversial issue in modern dialysis
-
Ronco C: Backfiltration: a controversial issue in modern dialysis. Int J Artif Organs 11: 69 74, 1988
-
(1988)
Int J Artif Organs
, vol.11
, pp. 69-74
-
-
Ronco, C.1
-
44
-
-
0026601992
-
Permeability of cellulosic and non-cellulosic membranes to endotoxin subunits and cytokine production during in-vitro haemodialysis
-
Urena P, Herbelin A, Zingraff J, Lair M, Man NK, Descamps-Latscha B, Drueke T: Permeability of cellulosic and non-cellulosic membranes to endotoxin subunits and cytokine production during in-vitro haemodialysis. Nephrol Dial Transplant 7: 16 28, 1992
-
(1992)
Nephrol Dial Transplant
, vol.7
, pp. 16-28
-
-
Urena, P.1
Herbelin, A.2
Zingraff, J.3
Lair, M.4
Man, N.K.5
Descamps-Latscha, B.6
Drueke, T.7
-
45
-
-
0023802873
-
Reuse of hemodialyzers. Results of nationwide surveillance for adverse effects
-
Alter MJ, Favero MS, Miller JK, Coleman PJ, Bland LA: Reuse of hemodialyzers. Results of nationwide surveillance for adverse effects. JAMA 260: 2073 2076, 1988
-
(1988)
JAMA
, vol.260
, pp. 2073-2076
-
-
Alter, M.J.1
Favero, M.S.2
Miller, J.K.3
Coleman, P.J.4
Bland, L.A.5
-
46
-
-
0025449503
-
LA: National surveillance of dialysis-associated diseases in the United States, 1988
-
Alter MJ, Favero MS, Moyer LA, Miller JK, Bland LA: National surveillance of dialysis-associated diseases in the United States, 1988. Trans Am Soc Artif Intern Organs 36: 107 118, 1990
-
(1990)
Trans Am Soc Artif Intern Organs
, vol.36
, pp. 107-118
-
-
Alter, M.J.1
Favero, M.S.2
Moyer, L.A.3
Miller, J.K.4
Bland5
-
47
-
-
0026935027
-
A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin
-
Pegues DA, Oettinger CW, Bland LA, Oliver JC, Arduino MJ, Aguero SM, McAllister SK, Gordon SM, Favero MS, Jarvis WR: A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin. J Am Soc Nephrol 3: 1002 1007, 1992
-
(1992)
J Am Soc Nephrol
, vol.3
, pp. 1002-1007
-
-
Pegues, D.A.1
Oettinger, C.W.2
Bland, L.A.3
Oliver, J.C.4
Arduino, M.J.5
Aguero, S.M.6
McAllister, S.K.7
Gordon, S.M.8
Favero, M.S.9
Jarvis, W.R.10
-
48
-
-
33645376602
-
Wielokrotne užycie dializatora. Prosty i bezpieczny sposób zmniejszenia kosztów dializy [Repeated use of dialyzer. A simple and safe method for lowering the cost of dialysis]
-
Twardowski Z, Lebek R, Nowak H, Gajdzik C: Wielokrotne užycie dializatora. Prosty i bezpieczny sposób zmniejszenia kosztów dializy [Repeated use of dialyzer. A simple and safe method for lowering the cost of dialysis]. Pol Arch Med Wewn 48: 171 176, 1972
-
(1972)
Pol Arch Med Wewn
, vol.48
, pp. 171-176
-
-
Twardowski, Z.1
Lebek, R.2
Nowak, H.3
Gajdzik, C.4
-
51
-
-
0021867247
-
Dialyzer performance over prolonged reuse
-
Gagnon RF, Kaye M: Dialyzer performance over prolonged reuse. Clin Nephrol 24: 21 27, 1985
-
(1985)
Clin Nephrol
, vol.24
, pp. 21-27
-
-
Gagnon, R.F.1
Kaye, M.2
-
52
-
-
0021431224
-
Revised standards for reuse of hemodialyzers
-
National Kidney Foundation:
-
National Kidney Foundation: Revised standards for reuse of hemodialyzers. Am J Kidney Dis 3: 466 468, 1984
-
(1984)
Am J Kidney Dis
, vol.3
, pp. 466-468
-
-
-
53
-
-
0024370069
-
Severe dialyzer dysfunction undetectable by standard reprocessing validation tests
-
Delmez JA, Weerts CA, Hasamear PD, Windus DW: Severe dialyzer dysfunction undetectable by standard reprocessing validation tests. Kidney Int 36: 478 484, 1989
-
(1989)
Kidney Int
, vol.36
, pp. 478-484
-
-
Delmez, J.A.1
Weerts, C.A.2
Hasamear, P.D.3
Windus, D.W.4
-
54
-
-
0007395668
-
National Kidney Foundation report on dialyzer reuse. Task Force on Reuse of Dialyzers, Council on Dialysis, National Kidney Foundation
-
National Kidney Foundation report on dialyzer reuse. Task Force on Reuse of Dialyzers, Council on Dialysis, National Kidney Foundation. Am J Kidney Dis 30: 859 871, 1997
-
(1997)
Am J Kidney Dis
, vol.30
, pp. 859-871
-
-
-
55
-
-
0025321635
-
Effect of reuse on dialyzer efficacy
-
Garred LJ, Canaud B, Flavier JL, Poux C, Polito-Bouloux C, Mion C: Effect of reuse on dialyzer efficacy. Artif Organs 14: 80 84, 1990
-
(1990)
Artif Organs
, vol.14
, pp. 80-84
-
-
Garred, L.J.1
Canaud, B.2
Flavier, J.L.3
Poux, C.4
Polito-Bouloux, C.5
Mion, C.6
-
56
-
-
0030766044
-
Maintaining blood compartment volume in dialyzers reprocessed with peracetic acid maintains Kt/V but not beta2-microglobulin removal
-
Ouseph R, Smith BP, Ward RA: Maintaining blood compartment volume in dialyzers reprocessed with peracetic acid maintains Kt/V but not beta2-microglobulin removal. Am J Kidney Dis 30: 501 506, 1997
-
(1997)
Am J Kidney Dis
, vol.30
, pp. 501-506
-
-
Ouseph, R.1
Smith, B.P.2
Ward, R.A.3
-
57
-
-
0344791708
-
Effects of hemodialyzer reuse on clearances of urea and β2-microglobulin. The Hemodialysis (HEMO) Study Group
-
Cheung AK, Agodoa LY, Daugirdas JT, Depner TA, Gotch FA, Greene T, Levin NW, Leypoldt JK: Effects of hemodialyzer reuse on clearances of urea and β2-microglobulin. The Hemodialysis (HEMO) Study Group. J Am Soc Nephrol 10: 117 127, 1999
-
(1999)
J Am Soc Nephrol
, vol.10
, pp. 117-127
-
-
Cheung, A.K.1
Agodoa, L.Y.2
Daugirdas, J.T.3
Depner, T.A.4
Gotch, F.A.5
Greene, T.6
Levin, N.W.7
Leypoldt, J.K.8
-
58
-
-
0028035163
-
The effect of dialyzer reuse on dialysis delivery
-
Sherman RA, Cody RP, Rogers ME, Solanchick JC: The effect of dialyzer reuse on dialysis delivery. Am J Kidney Dis 24: 924 926, 1994
-
(1994)
Am J Kidney Dis
, vol.24
, pp. 924-926
-
-
Sherman, R.A.1
Cody, R.P.2
Rogers, M.E.3
Solanchick, J.C.4
-
59
-
-
0031890712
-
Effect of formaldehyde/bleach reprocessing on in vivo performances of high-efficiency cellulose and high-flux polysulfone dialyzers
-
Murthy BVR, Sundaram S, Jaber BL, Perrella C, Meyer KB, Pereira BJG: Effect of formaldehyde/bleach reprocessing on in vivo performances of high-efficiency cellulose and high-flux polysulfone dialyzers. J Am Soc Nephrol 9: 464 472, 1998
-
(1998)
J Am Soc Nephrol
, vol.9
, pp. 464-472
-
-
Murthy, B.V.R.1
Sundaram, S.2
Jaber, B.L.3
Perrella, C.4
Meyer, K.B.5
Pereira, B.J.G.6
-
60
-
-
0022479890
-
Permeability and secondary membrane formation of a high flux polysulfone hemofilter
-
Röckel A, Hertel J, Fiegel P, Abdelhamid S, Panitz N, Walb D: Permeability and secondary membrane formation of a high flux polysulfone hemofilter. Kidney Int 30: 429 432, 1986
-
(1986)
Kidney Int
, vol.30
, pp. 429-432
-
-
Röckel, A.1
Hertel, J.2
Fiegel, P.3
Abdelhamid, S.4
Panitz, N.5
Walb, D.6
-
61
-
-
0031927768
-
Effect of hemodialyzer reuse: dissociation between clearances of small and large solutes
-
Leypoldt JK, Cheung AK, Deeter RB: Effect of hemodialyzer reuse: dissociation between clearances of small and large solutes. Am J Kidney Dis 32: 295 301, 1998
-
(1998)
Am J Kidney Dis
, vol.32
, pp. 295-301
-
-
Leypoldt, J.K.1
Cheung, A.K.2
Deeter, R.B.3
-
62
-
-
0027325293
-
The effect of dialyzer reprocessing on performance and β2-microglobulin removal using polysulfone membranes
-
Diaz RJ, Washburn S, Cauble L, Siskind MS, Van Wyck D: The effect of dialyzer reprocessing on performance and β2-microglobulin removal using polysulfone membranes. Am J Kidney Dis 21: 405 410, 1993
-
(1993)
Am J Kidney Dis
, vol.21
, pp. 405-410
-
-
Diaz, R.J.1
Washburn, S.2
Cauble, L.3
Siskind, M.S.4
Van Wyck, D.5
-
63
-
-
0028899012
-
Dialysate protein losses with bleach processed polysulphone dialyzers
-
Kaplan AA, Halley SE, Lapkin RA, Graeber CW, Graeber CA: Dialysate protein losses with bleach processed polysulphone dialyzers. Kidney Int 47: 573 578, 1995
-
(1995)
Kidney Int
, vol.47
, pp. 573-578
-
-
Kaplan, A.A.1
Halley, S.E.2
Lapkin, R.A.3
Graeber, C.W.4
Graeber, C.A.5
-
64
-
-
0345038842
-
Reuse with oxidizing agents leads to a loss of polyvinylpyrrolidone from polysulfone membrane [abstract]
-
Krautzig S, Mahiout A, Koch KM, Lemke HD: Reuse with oxidizing agents leads to a loss of polyvinylpyrrolidone from polysulfone membrane [abstract]. Blood Purif 12: 176, 1994
-
(1994)
Blood Purif
, vol.12
, pp. 176
-
-
Krautzig, S.1
Mahiout, A.2
Koch, K.M.3
Lemke, H.D.4
-
65
-
-
0242522354
-
Impact of bleach cleaning on the performance of dialyzers with polysulfone membranes processed for reuse using peracetic acid
-
Ward RA, Ouseph R: Impact of bleach cleaning on the performance of dialyzers with polysulfone membranes processed for reuse using peracetic acid. Artif Organs 27: 1029 1034, 2003
-
(2003)
Artif Organs
, vol.27
, pp. 1029-1034
-
-
Ward, R.A.1
Ouseph, R.2
-
66
-
-
0028198411
-
Analysis of the association of dialyzer reuse practices and patient outcomes
-
Held PJ, Wolfe RA, Gaylin DS, Port FK, Levin NW, Turenne MN: Analysis of the association of dialyzer reuse practices and patient outcomes. Am J Kidney Dis 23: 692 708, 1994
-
(1994)
Am J Kidney Dis
, vol.23
, pp. 692-708
-
-
Held, P.J.1
Wolfe, R.A.2
Gaylin, D.S.3
Port, F.K.4
Levin, N.W.5
Turenne, M.N.6
-
67
-
-
0035147483
-
Mortality risk by hemodialyzer reuse practice and dialyzer membrane characteristics: results from the USRDS dialysis morbidity and mortality study
-
Port FK, Wolfe RA, Hulbert-Shearon TE, Daugirdas JT, Agodoa LYC, Jones C, Orzol SM, Held PJ: Mortality risk by hemodialyzer reuse practice and dialyzer membrane characteristics: results from the USRDS dialysis morbidity and mortality study. Am J Kidney Dis 37: 276 286, 2001
-
(2001)
Am J Kidney Dis
, vol.37
, pp. 276-286
-
-
Port, F.K.1
Wolfe, R.A.2
Hulbert-Shearon, T.E.3
Daugirdas, J.T.4
Agodoa, L.Y.C.5
Jones, C.6
Orzol, S.M.7
Held, P.J.8
-
68
-
-
0036117890
-
To reuse or not to reuse? An economic evaluation of hemodialyzer reuse versus conventional single-use hemodialysis for chronic hemodialysis patients
-
Manns BJ, Taub K, Richardson RMA, Donaldson C: To reuse or not to reuse? An economic evaluation of hemodialyzer reuse versus conventional single-use hemodialysis for chronic hemodialysis patients. Int J Technol Assess Health Care 18 1 81 93, 2002
-
(2002)
Int J Technol Assess Health Care
, vol.18
, Issue.1
, pp. 81-93
-
-
Manns, B.J.1
Taub, K.2
Richardson, R.M.A.3
Donaldson, C.4
-
69
-
-
0029818258
-
Effect of dialyzer reuse on survival of patients treated with hemodialysis
-
Feldman HI, Kinosian M, Bilker WB, Simmons C, Holmes JH, Pauly MV, Escarce JJ: Effect of dialyzer reuse on survival of patients treated with hemodialysis. JAMA 276: 620 625, 1996
-
(1996)
JAMA
, vol.276
, pp. 620-625
-
-
Feldman, H.I.1
Kinosian, M.2
Bilker, W.B.3
Simmons, C.4
Holmes, J.H.5
Pauly, M.V.6
Escarce, J.J.7
-
70
-
-
0032707897
-
Association of dialyzer reuse and hospitalization rates among hemodialysis patients in the US
-
Feldman HI, Bilker WB, Hackett M, Simmons CW, Holmes JH, Pauly MV, Escarce JJ: Association of dialyzer reuse and hospitalization rates among hemodialysis patients in the US. Am J Nephrol 19: 641 648, 1999
-
(1999)
Am J Nephrol
, vol.19
, pp. 641-648
-
-
Feldman, H.I.1
Bilker, W.B.2
Hackett, M.3
Simmons, C.W.4
Holmes, J.H.5
Pauly, M.V.6
Escarce, J.J.7
-
71
-
-
0033758229
-
Characteristics and treatment of patients not reusing dialyzers in reuse units
-
Okechukwu CN, Orzol SM, Held PJ, Pereira BJ, Agodoa LY, Wolfe RA, Port FK: Characteristics and treatment of patients not reusing dialyzers in reuse units. Am J Kidney Dis 36: 991 999, 2000
-
(2000)
Am J Kidney Dis
, vol.36
, pp. 991-999
-
-
Okechukwu, C.N.1
Orzol, S.M.2
Held, P.J.3
Pereira, B.J.4
Agodoa, L.Y.5
Wolfe, R.A.6
Port, F.K.7
-
72
-
-
8344281361
-
Reprocessing dialyzers for multiple uses: recent analysis of death risks for patients
-
Lowrie EG, Li Z, Ofsthun N, Lazarus JM: Reprocessing dialyzers for multiple uses: recent analysis of death risks for patients. Nephrol Dial Transplant 19: 2823 2830, 2004
-
(2004)
Nephrol Dial Transplant
, vol.19
, pp. 2823-2830
-
-
Lowrie, E.G.1
Li, Z.2
Ofsthun, N.3
Lazarus, J.M.4
-
73
-
-
21644465205
-
Measurement of dialyzer clearance, dialysis time, and body size: death risk relationships among patients
-
Lowrie EG, Li Z, Ofsthun N, Lazarus JM: Measurement of dialyzer clearance, dialysis time, and body size: death risk relationships among patients. Kidney Int 66: 2077 2084, 2004
-
(2004)
Kidney Int
, vol.66
, pp. 2077-2084
-
-
Lowrie, E.G.1
Li, Z.2
Ofsthun, N.3
Lazarus, J.M.4
-
74
-
-
84943010095
-
Body composition, treatment time, and outcome in hemodialysis patients
-
Williams AJ, McArley A: Body composition, treatment time, and outcome in hemodialysis patients. J Ren Nutr 9 3 157 162, 1999
-
(1999)
J Ren Nutr
, vol.9
, Issue.3
, pp. 157-162
-
-
Williams, A.J.1
McArley, A.2
-
75
-
-
0029966395
-
Weekly duration of dialysis treatment - does it matter for survival?
-
Valderrábano F: Weekly duration of dialysis treatment - does it matter for survival? Nephrol Dial Transplant 11: 569 572, 1996
-
(1996)
Nephrol Dial Transplant
, vol.11
, pp. 569-572
-
-
Valderrábano, F.1
-
76
-
-
0032966949
-
Duration of dialysis session - was Hegel right?
-
Locatelli F, Manzoni C: Duration of dialysis session - was Hegel right? Nephrol Dial Transplant 14: 560 563, 1999
-
(1999)
Nephrol Dial Transplant
, vol.14
, pp. 560-563
-
-
Locatelli, F.1
Manzoni, C.2
-
77
-
-
0036007331
-
Management of the hemodialysis patient: a European perspective
-
Lameire N: Management of the hemodialysis patient: a European perspective. Blood Purif 20: 93 102, 2002
-
(2002)
Blood Purif
, vol.20
, pp. 93-102
-
-
Lameire, N.1
-
78
-
-
0027019277
-
Adequacy of long-term hemodialysis
-
Shaldon S: Adequacy of long-term hemodialysis. Curr Opin Nephrol Hypertens 1: 197 202, 1992
-
(1992)
Curr Opin Nephrol Hypertens
, vol.1
, pp. 197-202
-
-
Shaldon, S.1
-
79
-
-
16544367728
-
Reuse: what does the industry think?
-
97
-
Doss H, Carlson W: Reuse: what does the industry think? Nephrol News Issues 18: 95, 97, 2004
-
(2004)
Nephrol News Issues
, vol.18
, pp. 95
-
-
Doss, H.1
Carlson, W.2
-
80
-
-
0036265592
-
Effects of heat/citric acid reprocessing on high-flux polysulfone dialyzers
-
Cornelius RM, McClung WG, Richardson RMA, Estridge C, Plaskos N, Yip CM, Brash JL: Effects of heat/citric acid reprocessing on high-flux polysulfone dialyzers. ASAIO J 48: 45 56, 2002
-
(2002)
ASAIO J
, vol.48
, pp. 45-56
-
-
Cornelius, R.M.1
McClung, W.G.2
Richardson, R.M.A.3
Estridge, C.4
Plaskos, N.5
Yip, C.M.6
Brash, J.L.7
-
81
-
-
0347951263
-
Extended reuse of polysulfone hemodialysis membranes using citric acid and heat
-
Tonelli M, Dymond C, Gourishankar S, Jindal KK: Extended reuse of polysulfone hemodialysis membranes using citric acid and heat. ASAIO J 50: 98 101, 2004
-
(2004)
ASAIO J
, vol.50
, pp. 98-101
-
-
Tonelli, M.1
Dymond, C.2
Gourishankar, S.3
Jindal, K.K.4
-
82
-
-
0344542255
-
Efficacy of heat disinfection with the Aksys personal hemodialysis system
-
Kenley RS: Efficacy of heat disinfection with the Aksys personal hemodialysis system. Home Hemodial Int 1: 36 40, 1997
-
(1997)
Home Hemodial Int
, vol.1
, pp. 36-40
-
-
Kenley, R.S.1
-
83
-
-
0012515210
-
Effect of non-chemical hot water reuse on dialyzer performance [abstract]
-
James J, Twardowski ZJ, Blagg CR, Bower JD, Kjellstrand CM: Effect of non-chemical hot water reuse on dialyzer performance [abstract]. J Am Soc Nephrol 12: 267A, 2001
-
(2001)
J Am Soc Nephrol
, vol.12
-
-
James, J.1
Twardowski, Z.J.2
Blagg, C.R.3
Bower, J.D.4
Kjellstrand, C.M.5
-
84
-
-
33646697229
-
Hot water reuse (HWR) of dialysis filters gives smoother dialysis than single use (SU) or chemical reuse (CRU) [abstract]
-
Kjellstrand C, Twardowski ZJ, Bower J, Blagg CR: Hot water reuse (HWR) of dialysis filters gives smoother dialysis than single use (SU) or chemical reuse (CRU) [abstract]. J Am Soc Nephrol 14: 502A, 2003
-
(2003)
J Am Soc Nephrol
, vol.14
-
-
Kjellstrand, C.1
Twardowski, Z.J.2
Bower, J.3
Blagg, C.R.4
-
85
-
-
2342433035
-
The Aksys personal hemodialysis system
-
Kjellstrand CM, Blagg CR, Bower J, Twardowski ZJ: The Aksys personal hemodialysis system. Semin Dial 17: 151 153, 2004
-
(2004)
Semin Dial
, vol.17
, pp. 151-153
-
-
Kjellstrand, C.M.1
Blagg, C.R.2
Bower, J.3
Twardowski, Z.J.4
-
86
-
-
33646699210
-
106 Patient-years experience with the AKSYS PHD system for quotidian home hemodialysis [abstract]
-
Kjellstrand CM, Blagg CR, Bower J, Young B, Twardowski ZJ: 106 Patient-years experience with the AKSYS PHD system for quotidian home hemodialysis [abstract]. Hemodial Int 9: 80 81, 2005
-
(2005)
Hemodial Int
, vol.9
, pp. 80-81
-
-
Kjellstrand, C.M.1
Blagg, C.R.2
Bower, J.3
Young, B.4
Twardowski, Z.J.5
|