-
2
-
-
0035810399
-
Complement. First of two parts
-
Walport MJ. Complement. First of two parts. N. Engl. J. Med. 344(14), 1058-1066 (2001).
-
(2001)
N. Engl. J. Med.
, vol.344
, Issue.14
, pp. 1058-1066
-
-
Walport, M.J.1
-
3
-
-
0035849176
-
Complement. Second of two parts
-
Walport MJ. Complement. Second of two parts. N. Engl. J. Med. 344(15), 1140-1144 (2001).
-
(2001)
N. Engl. J. Med.
, vol.344
, Issue.15
, pp. 1140-1144
-
-
Walport, M.J.1
-
4
-
-
10944234587
-
Extracorporeal circulation
-
Edmunds HL, Cohn LH (Eds), McGraw-Hill Professional, NY, USA
-
Edmunds HL, Hessel EA, Colman RW, Menasche P. Extracorporeal circulation. In: Cardiac Surgery in the Adult. Edmunds HL, Cohn LH (Eds), McGraw-Hill Professional, NY, USA, 315-387 (2003).
-
(2003)
Cardiac Surgery in the Adult
, pp. 315-387
-
-
Edmunds, H.L.1
Hessel, E.A.2
Colman, R.W.3
Menasche, P.4
-
5
-
-
0344233286
-
Advances in the heart-lung machine after John and Mary Gibbon
-
Edmunds LH Jr. Advances in the heart-lung machine after John and Mary Gibbon. Ann. Thorac. Surg. 76(6), S2220-S2223 (2003).
-
(2003)
Ann. Thorac. Surg.
, vol.76
, Issue.6
-
-
Edmunds Jr., L.H.1
-
6
-
-
33646549045
-
Cardiopulmonary bypass: Technique and pathophysiology
-
Selke FW, del Nido PJ, Swanson SJ (Eds), Elsevier Saunders, PA, USA
-
Rubens FD. Cardiopulmonary bypass: technique and pathophysiology. In: Sabiston & Spencer Surgery of the Chest. Selke FW, del Nido PJ, Swanson SJ (Eds), Elsevier Saunders, PA, USA, 1061-1080 (2005).
-
(2005)
Sabiston & Spencer Surgery of the Chest
, pp. 1061-1080
-
-
Rubens, F.D.1
-
7
-
-
0036324822
-
Cardiopulmonary bypass technology transfer: Musings of a cardiac surgeon
-
Rubens FD. Cardiopulmonary bypass technology transfer: musings of a cardiac surgeon. J. Biomater. Sci. Polym. Ed. 13(4), 485-499 (2002).
-
(2002)
J. Biomater. Sci. Polym. Ed.
, vol.13
, Issue.4
, pp. 485-499
-
-
Rubens, F.D.1
-
8
-
-
22544482325
-
Bioactive technologies for hemocompatibility
-
Tanzi MC. Bioactive technologies for hemocompatibility. Expert Rev. Med. Devices 2(4), 473-492 (2005).
-
(2005)
Expert Rev. Med. Devices
, vol.2
, Issue.4
, pp. 473-492
-
-
Tanzi, M.C.1
-
9
-
-
0028468211
-
Biocompatible surfaces using methacryloylphosphorylcholine laurylmethacrylate copolymer
-
Campbell EJ, O'Byrne V, Stratford PW et al. Biocompatible surfaces using methacryloylphosphorylcholine laurylmethacrylate copolymer. ASAIO J. 40(3), M853-M857 (1994).
-
(1994)
ASAIO J.
, vol.40
, Issue.3
-
-
Campbell, E.J.1
O'Byrne, V.2
Stratford, P.W.3
-
10
-
-
0033055559
-
Endothelial dysfunction: From physiology to therapy
-
Mombouli JV, Vanhoutte PM. Endothelial dysfunction: from physiology to therapy. J. Mol. Cell. Cardiol. 31(1), 61-74 (1999).
-
(1999)
J. Mol. Cell. Cardiol.
, vol.31
, Issue.1
, pp. 61-74
-
-
Mombouli, J.V.1
Vanhoutte, P.M.2
-
11
-
-
0032956346
-
Hematologic evaluation of cardiopulmonary bypass circuits prepared with a novel block copolymer
-
Rubens FD, Labow RS, Lavallee GR et al. Hematologic evaluation of cardiopulmonary bypass circuits prepared with a novel block copolymer. Ann. Thorac. Surg. 67, 689-698 (1999).
-
(1999)
Ann. Thorac. Surg.
, vol.67
, pp. 689-698
-
-
Rubens, F.D.1
Labow, R.S.2
Lavallee, G.R.3
-
12
-
-
0018573264
-
Effect of thrombin on plasminogen activator release from isolated perfused dog leg
-
Kitaguchi H, Hijikata A, Hirata M. Effect of thrombin on plasminogen activator release from isolated perfused dog leg. Thromb. Res. 16, 407-415 (1979).
-
(1979)
Thromb. Res.
, vol.16
, pp. 407-415
-
-
Kitaguchi, H.1
Hijikata, A.2
Hirata, M.3
-
13
-
-
0026577704
-
Characterization of a functional thrombin receptor. Issues and opportunities
-
Coughlin SR, Vu TK, Hung DT, Wheaton VI. Characterization of a functional thrombin receptor. Issues and opportunities. J. Clin. Invest. 89(2), 351-355 (1992).
-
(1992)
J. Clin. Invest.
, vol.89
, Issue.2
, pp. 351-355
-
-
Coughlin, S.R.1
Vu, T.K.2
Hung, D.T.3
Wheaton, V.I.4
-
14
-
-
0027771480
-
Cytokine and complement levels in patients undergoing cardiopulmonary bypass
-
Steinberg JB, Kapelanski DP, Olson JD, Weiler JM. Cytokine and complement levels in patients undergoing cardiopulmonary bypass. J. Thorac. Cardiovasc. Surg. 106(6), 1008-1016 (1993).
-
(1993)
J. Thorac. Cardiovasc. Surg.
, vol.106
, Issue.6
, pp. 1008-1016
-
-
Steinberg, J.B.1
Kapelanski, D.P.2
Olson, J.D.3
Weiler, J.M.4
-
15
-
-
0022619349
-
Complement activation during cardiopulmonary bypass. Comparison of bubble and membrane oxygenators
-
Cavarocchi NC, Pluth JR, Schaff HV et al. Complement activation during cardiopulmonary bypass. Comparison of bubble and membrane oxygenators. J. Thorac. Cardiovasc. Surg. 91(2), 252-258 (1986).
-
(1986)
J. Thorac. Cardiovasc. Surg.
, vol.91
, Issue.2
, pp. 252-258
-
-
Cavarocchi, N.C.1
Pluth, J.R.2
Schaff, H.V.3
-
16
-
-
0019440292
-
Chemotactic activity generated from the fifth component of complement by plasma kallikrein of the rabbit
-
Wiggins RC, Giclas PC, Henson PM. Chemotactic activity generated from the fifth component of complement by plasma kallikrein of the rabbit. J. Exp. Med. 153(6), 1391-1404 (1981).
-
(1981)
J. Exp. Med.
, vol.153
, Issue.6
, pp. 1391-1404
-
-
Wiggins, R.C.1
Giclas, P.C.2
Henson, P.M.3
-
17
-
-
0014118360
-
A plasmin-split fragment of C'3 as a new chemotactic factor
-
Ward PA. A plasmin-split fragment of C'3 as a new chemotactic factor. J. Exp. Med. 126(2), 189-206 (1967).
-
(1967)
J. Exp. Med.
, vol.126
, Issue.2
, pp. 189-206
-
-
Ward, P.A.1
-
18
-
-
0031127587
-
Temporal studies on the deposition of complement on human colostrum IgA and serum IgG immobilized on methylated silicon
-
Tengvall P, Askendal A, Lundstrom I. Temporal studies on the deposition of complement on human colostrum IgA and serum IgG immobilized on methylated silicon. J. Biomed. Mater. Res. 35(1), 81-92 (1997).
-
(1997)
J. Biomed. Mater. Res.
, vol.35
, Issue.1
, pp. 81-92
-
-
Tengvall, P.1
Askendal, A.2
Lundstrom, I.3
-
19
-
-
2442501409
-
Biomaterial-associated thrombosis: Roles of coagulation factors, complement, platelets and leukocytes
-
Gorbet MB, Sefton MV. Biomaterial-associated thrombosis: roles of coagulation factors, complement, platelets and leukocytes. Biomaterials 25, 5681-5703 (2004).
-
(2004)
Biomaterials
, vol.25
, pp. 5681-5703
-
-
Gorbet, M.B.1
Sefton, M.V.2
-
20
-
-
0027251615
-
And it happened during our lifetime
-
Gott VL. And it happened during our lifetime. Ann. Thorac. Surg. 55(5), 1057-1064 (1993).
-
(1993)
Ann. Thorac. Surg.
, vol.55
, Issue.5
, pp. 1057-1064
-
-
Gott, V.L.1
-
22
-
-
0023739091
-
The role of biomaterials science in the next generation of artificial organ technology
-
Rosen JJ. The role of biomaterials science in the next generation of artificial organ technology. ASAIO Thins. 34(3), 163-167 (1988).
-
(1988)
ASAIO Thins.
, vol.34
, Issue.3
, pp. 163-167
-
-
Rosen, J.J.1
-
23
-
-
0033199710
-
Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation
-
Wendel HP, Ziemer G. Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation. Eur. J. Cardiothorac. Surg. 16(3), 342-350 (1999).
-
(1999)
Eur. J. Cardiothorac. Surg.
, vol.16
, Issue.3
, pp. 342-350
-
-
Wendel, H.P.1
Ziemer, G.2
-
24
-
-
0032736533
-
Serendipity and the development of heparin and carbon surfaces
-
Gott VL, Daggett RL. Serendipity and the development of heparin and carbon surfaces. Ann. Thorac. Surg. 68, S19-S22 (1999).
-
(1999)
Ann. Thorac. Surg.
, vol.68
-
-
Gott, V.L.1
Daggett, R.L.2
-
25
-
-
0009491819
-
Heparin bonding on colloidal graphite surfaces
-
Gott VL, Whiffen JD, Dutton RC. Heparin bonding on colloidal graphite surfaces. Science 14, 1297-1298 (1963).
-
(1963)
Science
, vol.14
, pp. 1297-1298
-
-
Gott, V.L.1
Whiffen, J.D.2
Dutton, R.C.3
-
26
-
-
0015294671
-
The role of surface energy in thrombogenesis
-
Baier RE. The role of surface energy in thrombogenesis. Bull. N Y Acad. Med. 48(2), 257-272 (1972).
-
(1972)
Bull. N Y Acad. Med.
, vol.48
, Issue.2
, pp. 257-272
-
-
Baier, R.E.1
-
27
-
-
0000098436
-
Platelet adhesion onto wettability gradient surfaces in the absence and presence of plasma proteins
-
Lee JH, Lee HB. Platelet adhesion onto wettability gradient surfaces in the absence and presence of plasma proteins. J. Biomed. Mater. Res. 41(2), 304-311 (1998).
-
(1998)
J. Biomed. Mater. Res.
, vol.41
, Issue.2
, pp. 304-311
-
-
Lee, J.H.1
Lee, H.B.2
-
28
-
-
0015140892
-
Nonthrombogenic surfaces: Critical review
-
Salzman EW. Nonthrombogenic surfaces: critical review. Blood 38(4), 509-523 (1971).
-
(1971)
Blood
, vol.38
, Issue.4
, pp. 509-523
-
-
Salzman, E.W.1
-
29
-
-
0019973320
-
Patterns of adsorption of proteins from human plasma onto foreign surfaces
-
Uniyal S, Brash JL. Patterns of adsorption of proteins from human plasma onto foreign surfaces. Thromb. Haemost. 47, 285-295 (1982).
-
(1982)
Thromb. Haemost.
, vol.47
, pp. 285-295
-
-
Uniyal, S.1
Brash, J.L.2
-
30
-
-
0001097441
-
Proteins; structure, properties, and adsorption to surfaces
-
Ratner BD, Hoffman AS, Schoen FJ, Lemon JE (Eds), Academic Press, CA, USA
-
Horbett TA. Proteins; structure, properties, and adsorption to surfaces. In: Biomaterials Science. An Introduction to Materials in Medicine. Ratner BD, Hoffman AS, Schoen FJ, Lemon JE (Eds), Academic Press, CA, USA, 133-141 (1996).
-
(1996)
Biomaterials Science. An Introduction to Materials in Medicine
, pp. 133-141
-
-
Horbett, T.A.1
-
31
-
-
0023915422
-
Mechanism of transient adsorption of fibrinogen from plasma to solid surfaces: Role of the contact and fibrinolytic systems
-
Brash JL, Scott CF, ten Hove P, Wojciechowski P, Colman RW. Mechanism of transient adsorption of fibrinogen from plasma to solid surfaces: role of the contact and fibrinolytic systems. Blood 71, 932-939 (1988).
-
(1988)
Blood
, vol.71
, pp. 932-939
-
-
Brash, J.L.1
Scott, C.F.2
ten Hove, P.3
Wojciechowski, P.4
Colman, R.W.5
-
32
-
-
0022520240
-
Does the conformation of adsorbed fibrinogen dictate platelet interactions with artificial surfaces?
-
Lindon JN, McManama G, Kushner L, Merrill EW, Salzman EW. Does the conformation of adsorbed fibrinogen dictate platelet interactions with artificial surfaces? Blood 68(2), 355-362 (1986).
-
(1986)
Blood
, vol.68
, Issue.2
, pp. 355-362
-
-
Lindon, J.N.1
McManama, G.2
Kushner, L.3
Merrill, E.W.4
Salzman, E.W.5
-
33
-
-
0021040217
-
A new non-thrombogenic surface prepared by selective covalent binding of heparin via a modified reducing terminal residue
-
Larm O, Larsson R, Olsson P. A new non-thrombogenic surface prepared by selective covalent binding of heparin via a modified reducing terminal residue. Biomater. Med. Devices Artif. Organs 11(2-3), 161-173 (1983).
-
(1983)
Biomater. Med. Devices Artif. Organs
, vol.11
, Issue.2-3
, pp. 161-173
-
-
Larm, O.1
Larsson, R.2
Olsson, P.3
-
34
-
-
0036672682
-
Coagulation, fibrinolysis, and cell activation in patients and shed mediastinal blood during coronary artery bypass grafting with a new heparin-coated surface
-
Johnell M, Elgue G, Larsson R, Larsson A, Thelin S, Siegbahn A. Coagulation, fibrinolysis, and cell activation in patients and shed mediastinal blood during coronary artery bypass grafting with a new heparin-coated surface. J. Thorac. Cardiovasc. Surg. 124(2), 321-332 (2002).
-
(2002)
J. Thorac. Cardiovasc. Surg.
, vol.124
, Issue.2
, pp. 321-332
-
-
Johnell, M.1
Elgue, G.2
Larsson, R.3
Larsson, A.4
Thelin, S.5
Siegbahn, A.6
-
35
-
-
9644275224
-
The influence of different heparin surface concentrations and antithrombin-binding capacity on inflammation and coagulation
-
Johnell M, Larsson R, Siegbahn A. The influence of different heparin surface concentrations and antithrombin-binding capacity on inflammation and coagulation. Biomaterials 26(14), 1731-1739 (2005).
-
(2005)
Biomaterials
, vol.26
, Issue.14
, pp. 1731-1739
-
-
Johnell, M.1
Larsson, R.2
Siegbahn, A.3
-
37
-
-
0033843761
-
Biocompatibility of heparin-coated extracorporeal bypass circuits: New heparin bonded bioline system
-
Tayama E, Hayashida N, Akasu K et al. Biocompatibility of heparin-coated extracorporeal bypass circuits: new heparin bonded bioline system. Artif. Organs 24(8), 618-623 (2000).
-
(2000)
Artif. Organs
, vol.24
, Issue.8
, pp. 618-623
-
-
Tayama, E.1
Hayashida, N.2
Akasu, K.3
-
38
-
-
0033971148
-
Comparison of Sarns 3M heparin bonded to Duraflo II and control circuits in a porcine model: Macro- and microanalysis of thrombi accumulation in circuit arterial filters
-
Larson DF, Arzouman D, Kleinert L, Patula V, Williams S. Comparison of Sarns 3M heparin bonded to Duraflo II and control circuits in a porcine model: macro- and microanalysis of thrombi accumulation in circuit arterial filters. Perfusion 15(1), 13-20 (2000).
-
(2000)
Perfusion
, vol.15
, Issue.1
, pp. 13-20
-
-
Larson, D.F.1
Arzouman, D.2
Kleinert, L.3
Patula, V.4
Williams, S.5
-
39
-
-
2342494852
-
The inflammatory response to cardiopulmonary bypass: A therapeutic overview
-
Rubens FD, Mesana T. The inflammatory response to cardiopulmonary bypass: a therapeutic overview. Perfusion 19(Suppl. 1), S5-S12 (2004).
-
(2004)
Perfusion
, vol.19
, Issue.SUPPL. 1
-
-
Rubens, F.D.1
Mesana, T.2
-
40
-
-
0027258016
-
On the mechanism of coagulation inhibition on surfaces with end point immobilized heparin
-
Elgue G, Blomback M, Olsson P, Riesenfeld J. On the mechanism of coagulation inhibition on surfaces with end point immobilized heparin. Thromb. Haemost. 70(2), 289-293 (1993).
-
(1993)
Thromb. Haemost.
, vol.70
, Issue.2
, pp. 289-293
-
-
Elgue, G.1
Blomback, M.2
Olsson, P.3
Riesenfeld, J.4
-
41
-
-
0029120179
-
Completely heparinized cardiopulmonary bypass and reduced systemic heparin: Clinical and hemostatic effects
-
Ovrum E, Holen EA, Tangen G et al. Completely heparinized cardiopulmonary bypass and reduced systemic heparin: clinical and hemostatic effects. Ann. Thorac. Surg. 60(2), 365-371 (1995).
-
(1995)
Ann. Thorac. Surg.
, vol.60
, Issue.2
, pp. 365-371
-
-
Ovrum, E.1
Holen, E.A.2
Tangen, G.3
-
42
-
-
0030217969
-
Heparin-bonded circuits with a reduced anticoagulation protocol in primary CABG: A prospective, randomized study
-
Aldea GS, Doursounian M, O'Gara P et al. Heparin-bonded circuits with a reduced anticoagulation protocol in primary CABG: a prospective, randomized study. Ann. Thorac. Surg. 62, 410-418 (1996).
-
(1996)
Ann. Thorac. Surg.
, vol.62
, pp. 410-418
-
-
Aldea, G.S.1
Doursounian, M.2
O'Gara, P.3
-
43
-
-
0345724177
-
Heparin-bonded circuits: Clinical outcomes and costs
-
Brown C. Heparin-bonded circuits: clinical outcomes and costs. Perfusion 13, 192-204 (1988).
-
(1988)
Perfusion
, vol.13
, pp. 192-204
-
-
Brown, C.1
-
44
-
-
0342981748
-
Attenuation of changes in leukocyte surface markers and complement activation with heparin-coated cardiopulmonary bypass
-
Moen O, Høgasen K, Fosse E et al. Attenuation of changes in leukocyte surface markers and complement activation with heparin-coated cardiopulmonary bypass. Ann. Thorac. Surg. 63, 105-111 (1997).
-
(1997)
Ann. Thorac. Surg.
, vol.63
, pp. 105-111
-
-
Moen, O.1
Høgasen, K.2
Fosse, E.3
-
45
-
-
0029152890
-
Heparin bonding of bypass circuits reduces cytokine release during cardiopulmonary bypass
-
Steinberg BM, Grossi EA, Schwartz DS et al. Heparin bonding of bypass circuits reduces cytokine release during cardiopulmonary bypass. Ann. Thorac. Surg. 60(3), 525-529 (1995).
-
(1995)
Ann. Thorac. Surg.
, vol.60
, Issue.3
, pp. 525-529
-
-
Steinberg, B.M.1
Grossi, E.A.2
Schwartz, D.S.3
-
46
-
-
0029811681
-
Induction of monocyte tissue factor procoagulant activity during coronary artery bypass surgery is reduced with heparin-coated extracorporeal circuit
-
Barstad RM, Ovrum E, Ringdal M-AL et al. Induction of monocyte tissue factor procoagulant activity during coronary artery bypass surgery is reduced with heparin-coated extracorporeal circuit. Br. J. Haematol. 94, 517-525 (1996).
-
(1996)
Br. J. Haematol.
, vol.94
, pp. 517-525
-
-
Barstad, R.M.1
Ovrum, E.2
Ringdal, M.-A.L.3
-
47
-
-
0028809946
-
Heparin causes platelet dysfunction and induces fibrinolysis before cardiopulmonary bypass
-
Khuri S, Valeri CR, Loscalzo J et al. Heparin causes platelet dysfunction and induces fibrinolysis before cardiopulmonary bypass. Ann. Thorac. Surg. 60, 1008-1014 (1995).
-
(1995)
Ann. Thorac. Surg.
, vol.60
, pp. 1008-1014
-
-
Khuri, S.1
Valeri, C.R.2
Loscalzo, J.3
-
48
-
-
0033922114
-
Heparin-induced platelet dysfunction and cardiopulmonary bypass
-
Muriithi EW, Belcher PR, Day SP, Menys VC, Wheatley DJ. Heparin-induced platelet dysfunction and cardiopulmonary bypass. Ann. Thorac. Surg. 69(6), 1827-1832 (2000).
-
(2000)
Ann. Thorac. Surg.
, vol.69
, Issue.6
, pp. 1827-1832
-
-
Muriithi, E.W.1
Belcher, P.R.2
Day, S.P.3
Menys, V.C.4
Wheatley, D.J.5
-
49
-
-
0023262178
-
C5a and thromboxane generation associated with pulmonary vaso- and broncho-constriction during protamine reversal of heparin
-
Morel DR, Zapol WM, Thomas SJ et al. C5a and thromboxane generation associated with pulmonary vaso- and broncho-constriction during protamine reversal of heparin. Anesthesiology 66(5), 597-604 (1987).
-
(1987)
Anesthesiology
, vol.66
, Issue.5
, pp. 597-604
-
-
Morel, D.R.1
Zapol, W.M.2
Thomas, S.J.3
-
50
-
-
8244238395
-
Clinical evaluation of Duraflo II heparin treated extracorporeal circulation circuits (2nd version). The European Working Group on heparin coated extracorporeal circulation circuits
-
Wildevuur CR, Jansen PG, Bezemer PD et al. Clinical evaluation of Duraflo II heparin treated extracorporeal circulation circuits (2nd version). The European Working Group on heparin coated extracorporeal circulation circuits. Eur. J. Cardiothorac. Surg. 11(4), 616-623 (1997).
-
(1997)
Eur. J. Cardiothorac. Surg.
, vol.11
, Issue.4
, pp. 616-623
-
-
Wildevuur, C.R.1
Jansen, P.G.2
Bezemer, P.D.3
-
51
-
-
0032957314
-
Heparin-coated circuits for high-risk patients: A multicenter, prospective, randomized trial
-
Ranucci M, Mazzucco A, Pessotto R et al. Heparin-coated circuits for high-risk patients: a multicenter, prospective, randomized trial. Ann. Thorac. Surg. 67, 994-1000 (1999).
-
(1999)
Ann. Thorac. Surg.
, vol.67
, pp. 994-1000
-
-
Ranucci, M.1
Mazzucco, A.2
Pessotto, R.3
-
52
-
-
9044236523
-
Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass
-
Gorman RC, Ziats NP, Rao AK et al. Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass. J. Thorac. Cardiovasc. Surg. 111, 1-12 (1996).
-
(1996)
J. Thorac. Cardiovasc. Surg.
, vol.111
, pp. 1-12
-
-
Gorman, R.C.1
Ziats, N.P.2
Rao, A.K.3
-
53
-
-
0028048887
-
Surface-bound heparin - Panacea or peril?
-
Edmunds LH. Surface-bound heparin - panacea or peril? Ann. Thorac. Surg. 58, 285-286 (1994).
-
(1994)
Ann. Thorac. Surg.
, vol.58
, pp. 285-286
-
-
Edmunds, L.H.1
-
54
-
-
0031033465
-
Heparin coating with aprotinin reduces blood activation during coronary artery operations
-
Baufreton C, Jansen PG, Le Besnerais P et al. Heparin coating with aprotinin reduces blood activation during coronary artery operations. Ann. Thorac. Surg. 63(1), 50-56 (1997).
-
(1997)
Ann. Thorac. Surg.
, vol.63
, Issue.1
, pp. 50-56
-
-
Baufreton, C.1
Jansen, P.G.2
Le Besnerais, P.3
-
55
-
-
0032959869
-
Heparin-coated cardiopulmonary bypass equipment. I. Biocompatibility markers and development of complications in a high-risk population
-
Videm V, Mollnes TE, Fosse E et al. Heparin-coated cardiopulmonary bypass equipment. I. Biocompatibility markers and development of complications in a high-risk population. J. Thorac. Cardiovasc. Surg. 117(4), 794-802 (1999).
-
(1999)
J. Thorac. Cardiovasc. Surg.
, vol.117
, Issue.4
, pp. 794-802
-
-
Videm, V.1
Mollnes, T.E.2
Fosse, E.3
-
56
-
-
0032905916
-
Heparin-coated cardiopulmonary bypass equipment. II. Mechanisms for reduced complement activation in vivo
-
Videm V, Mollnes TE, Bergh K et al. Heparin-coated cardiopulmonary bypass equipment. II. Mechanisms for reduced complement activation in vivo. J. Thorac. Cardiovasc. Surg. 117(4), 803-809 (1999).
-
(1999)
J. Thorac. Cardiovasc. Surg.
, vol.117
, Issue.4
, pp. 803-809
-
-
Videm, V.1
Mollnes, T.E.2
Bergh, K.3
-
57
-
-
0028142906
-
Complement activation during cardiopulmonary bypass: Effects of immobilized heparin
-
Pekna M, Hagman L, Halden E, Nilsson UR, Nilsson B, Thelin S. Complement activation during cardiopulmonary bypass: effects of immobilized heparin. Ann. Thorac. Surg. 58, 421-424 (1994).
-
(1994)
Ann. Thorac. Surg.
, vol.58
, pp. 421-424
-
-
Pekna, M.1
Hagman, L.2
Halden, E.3
Nilsson, U.R.4
Nilsson, B.5
Thelin, S.6
-
58
-
-
24944506525
-
The impact of heparin-coated circuits on hemodynamics during and after cardiopulmonary bypass
-
de Vroege R, Huybregts R, van Oeveren W et al. The impact of heparin-coated circuits on hemodynamics during and after cardiopulmonary bypass. Artif. Organs 29(6), 490-497 (2005).
-
(2005)
Artif. Organs
, vol.29
, Issue.6
, pp. 490-497
-
-
de Vroege, R.1
Huybregts, R.2
van Oeveren, W.3
-
59
-
-
0032708666
-
Increased adsorption of high molecular weight kininogen to heparin-coated artificial surfaces and correlation to hemocompatibility
-
Wendel HP, Weber N, Ziemer G. Increased adsorption of high molecular weight kininogen to heparin-coated artificial surfaces and correlation to hemocompatibility. Immunopharmacology 43(2-3), 149-153 (1999).
-
(1999)
Immunopharmacology
, vol.43
, Issue.2-3
, pp. 149-153
-
-
Wendel, H.P.1
Weber, N.2
Ziemer, G.3
-
60
-
-
0027514873
-
High molecular weight kininogen potentiates the heparin-accelerated inhibition of plasma kallikrein by antithrombin: Role for antithrombin in the regulation of kallikrein
-
Olson ST, Sheffer R, Francis AM. High molecular weight kininogen potentiates the heparin-accelerated inhibition of plasma kallikrein by antithrombin: role for antithrombin in the regulation of kallikrein. Biochemistry 32(45), 12136-12147 (1993).
-
(1993)
Biochemistry
, vol.32
, Issue.45
, pp. 12136-12147
-
-
Olson, S.T.1
Sheffer, R.2
Francis, A.M.3
-
61
-
-
0030746047
-
Heparin coating of extracorporeal circuits inhibits contact activation during cardiac operations
-
te Velthuis H, Baufreton C, Jansen PGM et al. Heparin coating of extracorporeal circuits inhibits contact activation during cardiac operations. J. Thorac. Cardiovasc. Surg. 114, 117-122 (1997).
-
(1997)
J. Thorac. Cardiovasc. Surg.
, vol.114
, pp. 117-122
-
-
te Velthuis, H.1
Baufreton, C.2
Jansen, P.G.M.3
-
62
-
-
0018670850
-
Surface-associated heparin inhibits zymosan-induced activation of the human alternative complement pathway by augmenting the regulatory action of the control proteins on particle-bound C3b
-
Kazatchkine MD, Fearon DT, Silbert JE, Austen KF. Surface-associated heparin inhibits zymosan-induced activation of the human alternative complement pathway by augmenting the regulatory action of the control proteins on particle-bound C3b. J. Exp. Med. 150(5), 1202-1215 (1979).
-
(1979)
J. Exp. Med.
, vol.150
, Issue.5
, pp. 1202-1215
-
-
Kazatchkine, M.D.1
Fearon, D.T.2
Silbert, J.E.3
Austen, K.F.4
-
63
-
-
0028784590
-
A new model for evaluation of biocompatibility: Combined determination of neoepitopes in blood and on artificial surfaces demonstrates reduced complement activation by immobilization of heparin
-
Mollnes TE, Riesenfeld J, Garred P et al. A new model for evaluation of biocompatibility: combined determination of neoepitopes in blood and on artificial surfaces demonstrates reduced complement activation by immobilization of heparin. Artif. Organs 19(9), 909-917 (1995).
-
(1995)
Artif. Organs
, vol.19
, Issue.9
, pp. 909-917
-
-
Mollnes, T.E.1
Riesenfeld, J.2
Garred, P.3
-
64
-
-
0031749146
-
Microdomain structure of polymeric surfaces - Potential for improving blood treatment procedures
-
Deppisch R, Gohl H, Smeby L. Microdomain structure of polymeric surfaces - potential for improving blood treatment procedures. Nephrol. Dial. Transplant. 13(6), 1354-1359 (1998).
-
(1998)
Nephrol. Dial. Transplant.
, vol.13
, Issue.6
, pp. 1354-1359
-
-
Deppisch, R.1
Gohl, H.2
Smeby, L.3
-
65
-
-
0028467860
-
Surface modifying additives for improved device-blood compatibility
-
Tsai C-C, Deppisch RM, Forrestal LJ et al. Surface modifying additives for improved device-blood compatibility. ASAIO J. 40, M619-M624 (1994).
-
(1994)
ASAIO J.
, vol.40
-
-
Tsai, C.-C.1
Deppisch, R.M.2
Forrestal, L.J.3
-
66
-
-
0027540251
-
Morphology and properties of polycaprolactone-poly(dimethyl siloxane)- Polycaprolactone triblock copolymers
-
Lovinger AJ, Han BJ, Padden FJ, Mirau PA. Morphology and properties of polycaprolactone-poly(dimethyl siloxane)- polycaprolactone triblock copolymers. J. Polymer Sci. 31, 115-123 (1993).
-
(1993)
J. Polymer Sci.
, vol.31
, pp. 115-123
-
-
Lovinger, A.J.1
Han, B.J.2
Padden, F.J.3
Mirau, P.A.4
-
67
-
-
0019570429
-
Effect of hydrophilic and hydrophobic microdomains on mode of interaction between block polymer and blood platelets
-
Okano T, Nishiyama S, Shinohara I et al. Effect of hydrophilic and hydrophobic microdomains on mode of interaction between block polymer and blood platelets. J. Biomed. Mater. Res. 15(3), 393-402 (1981).
-
(1981)
J. Biomed. Mater. Res.
, vol.15
, Issue.3
, pp. 393-402
-
-
Okano, T.1
Nishiyama, S.2
Shinohara, I.3
-
68
-
-
0022786779
-
Hydrophilic-hydrophobic microdomain surfaces having an ability to suppress platelet aggregation and their in vitro anti-thrombogenicity
-
Okano T, Aoyagi T, Kataoka K et al. Hydrophilic-hydrophobic microdomain surfaces having an ability to suppress platelet aggregation and their in vitro anti-thrombogenicity. J. Biomed. Mater. Res. 20, 919-927 (1986).
-
(1986)
J. Biomed. Mater. Res.
, vol.20
, pp. 919-927
-
-
Okano, T.1
Aoyagi, T.2
Kataoka, K.3
-
69
-
-
0034536106
-
SMA circuits reduce platelet consumption and platelet factor release during cardiac surgery
-
Defraigne JO, Pincemail J, Dekoster G et al. SMA circuits reduce platelet consumption and platelet factor release during cardiac surgery. Ann. Thorac. Surg. 70(6), 2075-2081 (2000).
-
(2000)
Ann. Thorac. Surg.
, vol.70
, Issue.6
, pp. 2075-2081
-
-
Defraigne, J.O.1
Pincemail, J.2
Dekoster, G.3
-
70
-
-
26844552555
-
A clinical, renal and immunological assessment of surface modifying additive treated (SMART) cardiopulmonary bypass circuits
-
Allen S, McBride WT Young IS et al. A clinical, renal and immunological assessment of surface modifying additive treated (SMART) cardiopulmonary bypass circuits. Perfusion 20(5), 255-262 (2005).
-
(2005)
Perfusion
, vol.20
, Issue.5
, pp. 255-262
-
-
Allen, S.1
McBride, W.T.2
Young, I.S.3
-
71
-
-
0035007741
-
Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model
-
Suhara H, Sawa Y, Nishimura M et al. Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model. Ann. Thorac. Surg. 71(5), 1603-1608 (2001).
-
(2001)
Ann. Thorac. Surg.
, vol.71
, Issue.5
, pp. 1603-1608
-
-
Suhara, H.1
Sawa, Y.2
Nishimura, M.3
-
72
-
-
0033866873
-
Effects of new polymer-coated extracorporeal circuits on biocompatibility during cardiopulmonary bypass
-
Saito N, Motoyama S, Sawamoto J. Effects of new polymer-coated extracorporeal circuits on biocompatibility during cardiopulmonary bypass. Artif. Organs 24(7), 547-554 (2000).
-
(2000)
Artif. Organs
, vol.24
, Issue.7
, pp. 547-554
-
-
Saito, N.1
Motoyama, S.2
Sawamoto, J.3
-
73
-
-
3142676678
-
PMEA coating of pump circuit and oxygenator may attenuate the early systemic inflammatory response in cardiopulmonary bypass surgery
-
Ueyama K, Nishimura K, Nishina T, Nakamura T, Ikeda T, Komeda M. PMEA coating of pump circuit and oxygenator may attenuate the early systemic inflammatory response in cardiopulmonary bypass surgery. ASAIO J. 50(4), 369-372 (2004).
-
(2004)
ASAIO J.
, vol.50
, Issue.4
, pp. 369-372
-
-
Ueyama, K.1
Nishimura, K.2
Nishina, T.3
Nakamura, T.4
Ikeda, T.5
Komeda, M.6
-
74
-
-
21244458098
-
Changes in platelet aggregation during cardiopulmonary bypass: Comparison of poly-2-methoxyethylacrylate and heparin as a circuit coating material
-
Izuha H, Hattori M, Igari T, Wakamatsu D, Watanabe M, Yokoyama H. Changes in platelet aggregation during cardiopulmonary bypass: comparison of poly-2-methoxyethylacrylate and heparin as a circuit coating material. J. Artif. Organs 8(1), 41-46 (2005).
-
(2005)
J. Artif. Organs
, vol.8
, Issue.1
, pp. 41-46
-
-
Izuha, H.1
Hattori, M.2
Igari, T.3
Wakamatsu, D.4
Watanabe, M.5
Yokoyama, H.6
-
75
-
-
0029242996
-
Platelet activation in whole blood by artificial surfaces: Identification of platelet-derived microparticles and activated platelet binding to leukocytes as material-induced activation events
-
Gemmell CH, Ramirez SM, Yeo EL, Sefton MV. Platelet activation in whole blood by artificial surfaces: identification of platelet-derived microparticles and activated platelet binding to leukocytes as material-induced activation events. J. Lab. Clin. Med. 125(2), 276-287 (1995).
-
(1995)
J. Lab. Clin. Med.
, vol.125
, Issue.2
, pp. 276-287
-
-
Gemmell, C.H.1
Ramirez, S.M.2
Yeo, E.L.3
Sefton, M.V.4
-
76
-
-
0031238482
-
Clinical evaluation of a silicone coated hollow fiber oxygenator
-
Shimono, T, Shomura Y, Tani K et al. Clinical evaluation of a silicone coated hollow fiber oxygenator. ASAIO J. 43(5), M735-M739 (1997).
-
(1997)
ASAIO J.
, vol.43
, Issue.5
-
-
Shimono, T.1
Shomura, Y.2
Tani, K.3
-
77
-
-
0033966748
-
Biocompatibility of silicone-coated oxygenator in cardiopulmonary bypass
-
Shimamoto A, Kanemitsu S, Fujinaga K et al. Biocompatibility of silicone-coated oxygenator in cardiopulmonary bypass. Ann. Thorac. Surg. 69(1), 115-120 (2000).
-
(2000)
Ann. Thorac. Surg.
, vol.69
, Issue.1
, pp. 115-120
-
-
Shimamoto, A.1
Kanemitsu, S.2
Fujinaga, K.3
-
78
-
-
0022608874
-
Biomembranes as models for polymer surfaces. II. The syntheses of reactive species for covalent coupling of phosphorylcholine to polymer surfaces
-
Durrani AA, Hayward JA, Chapman D. Biomembranes as models for polymer surfaces. II. The syntheses of reactive species for covalent coupling of phosphorylcholine to polymer surfaces. Biomaterials 7(2), 121-125 (1986).
-
(1986)
Biomaterials
, vol.7
, Issue.2
, pp. 121-125
-
-
Durrani, A.A.1
Hayward, J.A.2
Chapman, D.3
-
79
-
-
0034347726
-
Evaluation of biocompatibility of the surface of polyethylene films modified with various water soluble polymers using Ar plasma-post polymerization technique
-
Sugiyama K, Matsumoto T, Yamazaki Y. Evaluation of biocompatibility of the surface of polyethylene films modified with various water soluble polymers using Ar plasma-post polymerization technique. Macromol. Mater. Eng. 282, 5-12 (2000).
-
(2000)
Macromol. Mater. Eng.
, vol.282
, pp. 5-12
-
-
Sugiyama, K.1
Matsumoto, T.2
Yamazaki, Y.3
-
80
-
-
0033077881
-
The reduced adsorption of proteins at the phosphoryl choline incorporated polymer-water interface
-
Murphy EF, Lu JR, Brewer J, Russell J, Penfold J. The reduced adsorption of proteins at the phosphoryl choline incorporated polymer-water interface. Langmuir 15, 1313-1322 (1999).
-
(1999)
Langmuir
, vol.15
, pp. 1313-1322
-
-
Murphy, E.F.1
Lu, J.R.2
Brewer, J.3
Russell, J.4
Penfold, J.5
-
81
-
-
0036533087
-
Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation
-
Lewis AL, Tolhurst LA, Stratford PW. Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation. Biomaterials 23, 1697-1706 (2002).
-
(2002)
Biomaterials
, vol.23
, pp. 1697-1706
-
-
Lewis, A.L.1
Tolhurst, L.A.2
Stratford, P.W.3
-
82
-
-
0036436327
-
Long-term stability of a coronary stent coating post-implantation
-
Lewis AL, Furze JD, Small S et al. Long-term stability of a coronary stent coating post-implantation. J. Biomed. Mater. Res. 63(6), 699-705 (2002).
-
(2002)
J. Biomed. Mater. Res.
, vol.63
, Issue.6
, pp. 699-705
-
-
Lewis, A.L.1
Furze, J.D.2
Small, S.3
-
83
-
-
0034332701
-
Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface
-
De Somer F, Francois K, van Oeveren W et al. Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface. Eur. J. Cardiothorac. Surg. 18(5), 602-606 (2000).
-
(2000)
Eur. J. Cardiothorac. Surg.
, vol.18
, Issue.5
, pp. 602-606
-
-
De Somer, F.1
Francois, K.2
van Oeveren, W.3
-
84
-
-
0028941017
-
Retransfusion of suctioned blood during cardiopulmonary bypass impairs hemostasis
-
de Haan J, Boonstra PW, Monnink SHJ, Ebels T, van Oeveren W. Retransfusion of suctioned blood during cardiopulmonary bypass impairs hemostasis. Ann. Thorac. Surg. 59, 901-907 (1995).
-
(1995)
Ann. Thorac. Surg.
, vol.59
, pp. 901-907
-
-
de Haan, J.1
Boonstra, P.W.2
Monnink, S.H.J.3
Ebels, T.4
van Oeveren, W.5
-
85
-
-
0030004172
-
Pericardial blood activates the extrinsic coagulation pathway during clinical cardiopulmonary bypass
-
Chung JH, Gikakis N, Rao K, Drake TA, Colman RW, Edmunds LH. Pericardial blood activates the extrinsic coagulation pathway during clinical cardiopulmonary bypass. Circulation 93, 2014-2018 (1996).
-
(1996)
Circulation
, vol.93
, pp. 2014-2018
-
-
Chung, J.H.1
Gikakis, N.2
Rao, K.3
Drake, T.A.4
Colman, R.W.5
Edmunds, L.H.6
-
86
-
-
0036587134
-
Tissue factor as the main activator of the coagulation system during cardiopulmonary bypass
-
De Somer F, Van Belleghem Y, Caes F et al. Tissue factor as the main activator of the coagulation system during cardiopulmonary bypass. J. Thorac. Cardiovasc. Surg. 123(5), 951-958 (2002).
-
(2002)
J. Thorac. Cardiovasc. Surg.
, vol.123
, Issue.5
, pp. 951-958
-
-
De Somer, F.1
Van Belleghem, Y.2
Caes, F.3
-
87
-
-
0027435353
-
Activation of fibrinolysis in the pericardial cavity during cardiopulmonary bypass
-
Tabuchi N, de Haan J, Boonstra PW, van Oeveren W. Activation of fibrinolysis in the pericardial cavity during cardiopulmonary bypass. J. Thorac. Cardiovasc. Surg. 106, 828-833 (1993).
-
(1993)
J. Thorac. Cardiovasc. Surg.
, vol.106
, pp. 828-833
-
-
Tabuchi, N.1
de Haan, J.2
Boonstra, P.W.3
van Oeveren, W.4
-
88
-
-
0025146426
-
Clot-bound thrombin is protected from inhibition by heparin-antithrombin III but is susceptible to inactivation by antithrombin III- independent inhibitors
-
Weitz JI, Hudoba M, Massel D, Maraganore J, Hirsh J. Clot-bound thrombin is protected from inhibition by heparin-antithrombin III but is susceptible to inactivation by antithrombin III- independent inhibitors. J. Clin. Invest. 86, 385-391 (1990).
-
(1990)
J. Clin. Invest.
, vol.86
, pp. 385-391
-
-
Weitz, J.I.1
Hudoba, M.2
Massel, D.3
Maraganore, J.4
Hirsh, J.5
-
89
-
-
0030942790
-
Monocyte tissue factor expression, cell activation, and thrombin formation during cardiopulmonary bypass: A clinical study
-
Ernofsson M, Thelin S, Siegbahn A. Monocyte tissue factor expression, cell activation, and thrombin formation during cardiopulmonary bypass: a clinical study. J. Thorac. Cardiovasc. Surg. 113, 576-584 (1997).
-
(1997)
J. Thorac. Cardiovasc. Surg.
, vol.113
, pp. 576-584
-
-
Ernofsson, M.1
Thelin, S.2
Siegbahn, A.3
-
90
-
-
0031981147
-
Direct activation of factor X by monocytes occurs during cardiopulmonary bypass
-
Parratt R, Hunt BJ. Direct activation of factor X by monocytes occurs during cardiopulmonary bypass. Br. J. Haematol. 101, 40-46 (1998).
-
(1998)
Br. J. Haematol.
, vol.101
, pp. 40-46
-
-
Parratt, R.1
Hunt, B.J.2
-
91
-
-
23644441293
-
Plasma tissue factor plus activated peripheral mononuclear cells activate factors VII and X in cardiac surgical wounds
-
Hattori T, Khan MM, Colman RW, Edmunds LH Jr. Plasma tissue factor plus activated peripheral mononuclear cells activate factors VII and X in cardiac surgical wounds. J. Am. Coll. Cardiol. 46(4), 707-713 (2005).
-
(2005)
J. Am. Coll. Cardiol.
, vol.46
, Issue.4
, pp. 707-713
-
-
Hattori, T.1
Khan, M.M.2
Colman, R.W.3
Edmunds Jr., L.H.4
-
92
-
-
28344447156
-
Miniaturized cardiopulmonary bypass in coronary artery bypass surgery: Marginal impact on inflammation and coagulation but loss of safety margins
-
Nollert G, Schwabenland I, Maktav D et al. Miniaturized cardiopulmonary bypass in coronary artery bypass surgery: marginal impact on inflammation and coagulation but loss of safety margins. Ann. Thorac. Surg. 80(6), 2326-2332 (2005).
-
(2005)
Ann. Thorac. Surg.
, vol.80
, Issue.6
, pp. 2326-2332
-
-
Nollert, G.1
Schwabenland, I.2
Maktav, D.3
-
93
-
-
1442349191
-
Current status and outcomes of coronary revascularization 1999 to 2002: 148,396 surgical and percutaneous procedures
-
Mack MJ, Brown PP, Kugelmass AD et al. Current status and outcomes of coronary revascularization 1999 to 2002: 148,396 surgical and percutaneous procedures. Ann. Thorac. Surg. 77(3), 761-766 (2004).
-
(2004)
Ann. Thorac. Surg.
, vol.77
, Issue.3
, pp. 761-766
-
-
Mack, M.J.1
Brown, P.P.2
Kugelmass, A.D.3
|