-
1
-
-
73049136842
-
Functional electrotherapy: stimulation of the peroneal nerve synchronised with the swing phase of the gait of hemiplegic patients
-
Liberson W.T., Holmquest H.J., Scot D., and Dow M. Functional electrotherapy: stimulation of the peroneal nerve synchronised with the swing phase of the gait of hemiplegic patients. Arch Phys Med Rehabil 42 (1961) 101-105
-
(1961)
Arch Phys Med Rehabil
, vol.42
, pp. 101-105
-
-
Liberson, W.T.1
Holmquest, H.J.2
Scot, D.3
Dow, M.4
-
2
-
-
0030703706
-
The effects of common peroneal stimulation on the effort and speed of walking: a randomized controlled trial with chronic hemiplegic patients
-
Burridge J., Taylor P., Wood D., and Swain I. The effects of common peroneal stimulation on the effort and speed of walking: a randomized controlled trial with chronic hemiplegic patients. Clin Rehab 11 (1997) 201-210
-
(1997)
Clin Rehab
, vol.11
, pp. 201-210
-
-
Burridge, J.1
Taylor, P.2
Wood, D.3
Swain, I.4
-
3
-
-
0030949380
-
Experience of clinical use of the Odstock dropped foot stimulator
-
Burridge J., Taylor P., Hagan S., and Swain I. Experience of clinical use of the Odstock dropped foot stimulator. Artif Organs 21 3 (1997) 254-260
-
(1997)
Artif Organs
, vol.21
, Issue.3
, pp. 254-260
-
-
Burridge, J.1
Taylor, P.2
Hagan, S.3
Swain, I.4
-
4
-
-
0037213019
-
Functional electrical stimulation and rehabilitation-an hypothesis
-
Rushton D.N. Functional electrical stimulation and rehabilitation-an hypothesis. Med Eng Phys 25 (2003) 75-78
-
(2003)
Med Eng Phys
, vol.25
, pp. 75-78
-
-
Rushton, D.N.1
-
5
-
-
0032763417
-
Clinical use of the Odstock dropped foot stimulator: its effect on the speed and effort of walking
-
Taylor P.N., Burridge J.H., Dunkerley A.L., Wood D.E., Norton J.A., Singleton C., et al. Clinical use of the Odstock dropped foot stimulator: its effect on the speed and effort of walking. Arch Phys Med Rehabil 80 12 (1999) 1577-1583
-
(1999)
Arch Phys Med Rehabil
, vol.80
, Issue.12
, pp. 1577-1583
-
-
Taylor, P.N.1
Burridge, J.H.2
Dunkerley, A.L.3
Wood, D.E.4
Norton, J.A.5
Singleton, C.6
-
6
-
-
0014931017
-
Catch properties in single mammalian motor units
-
Burke R.E., Rudomin P., and Zajac F.E. Catch properties in single mammalian motor units. Science 168 (1970) 122-124
-
(1970)
Science
, vol.168
, pp. 122-124
-
-
Burke, R.E.1
Rudomin, P.2
Zajac, F.E.3
-
7
-
-
33646481185
-
-
Popovic D, editor. Advances in external control of human extremities proceedings I-X. Dubrovnik, 1962-1990. Originally published by the Yugoslav Committee for ETRAN Kneza Milosa 9, Belgrade, Yugoslavia, ISBN: 8676210012 http://www.smi.hst.aau.dk/phdkotor/echecd/index.html.
-
-
-
-
8
-
-
0032814260
-
Effects of length on the catchlike property of human quadriceps femoris muscle
-
Lee S.C.K., Gerdom M.L., and Binder-Macleod S.A. Effects of length on the catchlike property of human quadriceps femoris muscle. Phys Ther 79 (1999) 738-748
-
(1999)
Phys Ther
, vol.79
, pp. 738-748
-
-
Lee, S.C.K.1
Gerdom, M.L.2
Binder-Macleod, S.A.3
-
9
-
-
0033811937
-
Muscle fatigue induced by stimulation with and without doublets
-
Bigland-Ritchie B., Zijdewind I., and Thomas C.K. Muscle fatigue induced by stimulation with and without doublets. Muscle & Nerve 23 9 (2000) 1348-1355
-
(2000)
Muscle & Nerve
, vol.23
, Issue.9
, pp. 1348-1355
-
-
Bigland-Ritchie, B.1
Zijdewind, I.2
Thomas, C.K.3
-
10
-
-
0037381502
-
Fatigability and variable-frequency train stimulation of human skeletal muscles
-
Bickel S.C., Slade J.M., Warren G.L., and Dudley G.A. Fatigability and variable-frequency train stimulation of human skeletal muscles. Phys Ther 83 (2003) 4
-
(2003)
Phys Ther
, vol.83
, pp. 4
-
-
Bickel, S.C.1
Slade, J.M.2
Warren, G.L.3
Dudley, G.A.4
-
11
-
-
33646470959
-
Pattern of pulses that maximise force output from single human thenar motor units
-
Thomas C.K., Johansson R.S., and Bigland-Ritchie B. Pattern of pulses that maximise force output from single human thenar motor units. Am J Physiol (2002) J680-J681
-
(2002)
Am J Physiol
-
-
Thomas, C.K.1
Johansson, R.S.2
Bigland-Ritchie, B.3
-
12
-
-
0029347477
-
Reducing muscle fatigue in FES applications by stimulating with N-Let pulse trains
-
Karu Z.Z., Durfee W.K., and Barzilai A.M. Reducing muscle fatigue in FES applications by stimulating with N-Let pulse trains. IEEE Trans BME 42 (1995) 809-817
-
(1995)
IEEE Trans BME
, vol.42
, pp. 809-817
-
-
Karu, Z.Z.1
Durfee, W.K.2
Barzilai, A.M.3
-
13
-
-
33646483337
-
Effect of modifying stimulation profile on loading response during FES-corrected drop foot
-
Maroochydore, Queensland, Australia, July 1-5 Poster presentation No. 1.8
-
O'Halloran T., Haugland M., Lyons G.M., and Sinkjær T. Effect of modifying stimulation profile on loading response during FES-corrected drop foot. From technology to market... Bridging the gap, 2003 International Functional Electrical Stimulation Society Conference (IFESS, 2003). Maroochydore, Queensland, Australia, July 1-5 (2003) 226-230 Poster presentation No. 1.8
-
(2003)
From technology to market... Bridging the gap, 2003 International Functional Electrical Stimulation Society Conference (IFESS, 2003)
, pp. 226-230
-
-
O'Halloran, T.1
Haugland, M.2
Lyons, G.M.3
Sinkjær, T.4
-
14
-
-
0033034810
-
Apparatus to measure simultaneously 14 isometric leg joint moments. Part 2. Multi-moment chair system
-
Wood D.E., Donaldson N.N., and Perkins T.A. Apparatus to measure simultaneously 14 isometric leg joint moments. Part 2. Multi-moment chair system. Med Biol Eng Comput 37 2 (1999) 148-154
-
(1999)
Med Biol Eng Comput
, vol.37
, Issue.2
, pp. 148-154
-
-
Wood, D.E.1
Donaldson, N.N.2
Perkins, T.A.3
-
15
-
-
0036192877
-
Metabolic costs of force generation for constant frequency and catchlike inducing electrical stimulation in human tibialis anterior muscle
-
Ratkevicius A., and Quistorff B. Metabolic costs of force generation for constant frequency and catchlike inducing electrical stimulation in human tibialis anterior muscle. Muscle Nerve 25 (2002) 419-426
-
(2002)
Muscle Nerve
, vol.25
, pp. 419-426
-
-
Ratkevicius, A.1
Quistorff, B.2
-
16
-
-
0030894764
-
Doublet potentiation during eccentric and concentric contractions of cat soleus muscle
-
Sandercock T.G., and Heckman C.J. Doublet potentiation during eccentric and concentric contractions of cat soleus muscle. J Appl Physiol 4 (1997)
-
(1997)
J Appl Physiol
, vol.4
-
-
Sandercock, T.G.1
Heckman, C.J.2
-
17
-
-
33646474249
-
Muscle activity during normal walking and its relevance for the functional electrical stimulation applications
-
Vienna, Austria, September 12-15. 3-900928-05-3 Session 2 Paraplegia, Upper Motor Neuron Lesion
-
Mangold S., Keller T., and Popovic M.R. Muscle activity during normal walking and its relevance for the functional electrical stimulation applications. Proceedings of 7th Vienna international workshop on functional electrical stimulation. Vienna, Austria, September 12-15 (2001). 3-900928-05-3 18-21 Session 2 Paraplegia, Upper Motor Neuron Lesion
-
(2001)
Proceedings of 7th Vienna international workshop on functional electrical stimulation
, pp. 18-21
-
-
Mangold, S.1
Keller, T.2
Popovic, M.R.3
-
18
-
-
0036069744
-
Speed dependence of averaged EMG profiles in walking
-
Hof A.L., Elzinga H., Grimmius W., and Halbertsma J.P.K. Speed dependence of averaged EMG profiles in walking. Gait & Posture 16 1 (2002) 78-86
-
(2002)
Gait & Posture
, vol.16
, Issue.1
, pp. 78-86
-
-
Hof, A.L.1
Elzinga, H.2
Grimmius, W.3
Halbertsma, J.P.K.4
-
19
-
-
33646486847
-
-
MAXIM analogue-readers newsletter. APP 1155, June 21; 2005. http://dbserv.maxim-ic.com/appnotes.cfm/appnote_number/1155/.
-
-
-
-
20
-
-
0036231789
-
A versitle drop foot stimulator for research applications
-
Lyons G.M., and O'Keefe D.T. A versitle drop foot stimulator for research applications. Med Eng Phys 24 (2002) 237-242
-
(2002)
Med Eng Phys
, vol.24
, pp. 237-242
-
-
Lyons, G.M.1
O'Keefe, D.T.2
-
21
-
-
18344384406
-
The Vienna functional electrical stimulation system for restoration of walking functions in spastic paraplegia
-
Bijak M., Mayr W., Rakos M., Hofer C., Lanmuller H., Rafolt D., et al. The Vienna functional electrical stimulation system for restoration of walking functions in spastic paraplegia. Art Organs 26 3 (2002) 224-227
-
(2002)
Art Organs
, vol.26
, Issue.3
, pp. 224-227
-
-
Bijak, M.1
Mayr, W.2
Rakos, M.3
Hofer, C.4
Lanmuller, H.5
Rafolt, D.6
|