-
1
-
-
1842423289
-
Results of permanent prostate brachytherapy, 13 years of experience at a single institution
-
Battermann J.J., Boon T.A., and Moerland M.A. Results of permanent prostate brachytherapy, 13 years of experience at a single institution. Radiother Oncol 71 (2004) 23-28
-
(2004)
Radiother Oncol
, vol.71
, pp. 23-28
-
-
Battermann, J.J.1
Boon, T.A.2
Moerland, M.A.3
-
2
-
-
1942489083
-
Assessment of radiation safety instructions to patients based on measured dose rates following prostate brachytherapy
-
Dauer L.T., Zelefsky M.J., Horan C., Yamada Y., and St Germain J. Assessment of radiation safety instructions to patients based on measured dose rates following prostate brachytherapy. Brachytherapy 3 (2004) 1-6
-
(2004)
Brachytherapy
, vol.3
, pp. 1-6
-
-
Dauer, L.T.1
Zelefsky, M.J.2
Horan, C.3
Yamada, Y.4
St Germain, J.5
-
3
-
-
0035450305
-
10-year biochemical (prostate-specific antigen) control of prostate cancer with (125)I brachytherapy
-
Grimm P.D., Blasko J.C., Sylvester J.E., Meier R.M., and Cavanagh W. 10-year biochemical (prostate-specific antigen) control of prostate cancer with (125)I brachytherapy. Int J Radiat Oncol Biol Phys 51 (2001) 31-40
-
(2001)
Int J Radiat Oncol Biol Phys
, vol.51
, pp. 31-40
-
-
Grimm, P.D.1
Blasko, J.C.2
Sylvester, J.E.3
Meier, R.M.4
Cavanagh, W.5
-
4
-
-
0037295465
-
Impact of target volume coverage with Rariation Therapy Oncology Group (RTOG) 98-05 guidelines for transrectal ultrasound guided permanent Iodine-125 prostate implants
-
Horwitz E.M., Mitra R.K., Uzzo R.G., et al. Impact of target volume coverage with Rariation Therapy Oncology Group (RTOG) 98-05 guidelines for transrectal ultrasound guided permanent Iodine-125 prostate implants. Radiother Oncol 66 (2003) 173-179
-
(2003)
Radiother Oncol
, vol.66
, pp. 173-179
-
-
Horwitz, E.M.1
Mitra, R.K.2
Uzzo, R.G.3
-
5
-
-
0141504142
-
Biochemical outcomes after prostate brachytherapy with 5-year minimal follow-up: importance of patient selection and implant quality
-
Kollmeier M.A., Stock R., and Stone N. Biochemical outcomes after prostate brachytherapy with 5-year minimal follow-up: importance of patient selection and implant quality. Int J Radiat Oncol Biol Phys 57 (2003) 645-653
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.57
, pp. 645-653
-
-
Kollmeier, M.A.1
Stock, R.2
Stone, N.3
-
6
-
-
3543109598
-
Idealized line source configuration for permanent 125I prostate implants
-
Leclerc G., Lavallee M.C., Tubic D., Metivier J., Vigneault E., and Beaulieu L. Idealized line source configuration for permanent 125I prostate implants. Radiother Oncol 72 (2004) 213-220
-
(2004)
Radiother Oncol
, vol.72
, pp. 213-220
-
-
Leclerc, G.1
Lavallee, M.C.2
Tubic, D.3
Metivier, J.4
Vigneault, E.5
Beaulieu, L.6
-
7
-
-
0142186677
-
Long-term multi-institutional analysis of stage T1-T2 prostate cancer treated with radiotherapy in the PSA era
-
Kuban D.A., Thames H.D., Levy L.B., et al. Long-term multi-institutional analysis of stage T1-T2 prostate cancer treated with radiotherapy in the PSA era. Int J Radiat Oncol Biol Phys 57 (2003) 915-928
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.57
, pp. 915-928
-
-
Kuban, D.A.1
Thames, H.D.2
Levy, L.B.3
-
8
-
-
1842579711
-
Comparative study of permanent interstitial prostate brachytherapy post-implant evaluation among seven Italian institutes
-
Mangili P., Stea L., Cattani F., et al. Comparative study of permanent interstitial prostate brachytherapy post-implant evaluation among seven Italian institutes. Radiother Oncol 71 (2004) 13-21
-
(2004)
Radiother Oncol
, vol.71
, pp. 13-21
-
-
Mangili, P.1
Stea, L.2
Cattani, F.3
-
9
-
-
1542781321
-
Comparison between two iodine-125 brachytherapy implant techniques: pre-planning and intra-operative by various dosimetry quality indicators
-
Matzkin H., Kaver I., Bramante-Schreiber L., et al. Comparison between two iodine-125 brachytherapy implant techniques: pre-planning and intra-operative by various dosimetry quality indicators. Radiother Oncol 68 (2003) 289-294
-
(2003)
Radiother Oncol
, vol.68
, pp. 289-294
-
-
Matzkin, H.1
Kaver, I.2
Bramante-Schreiber, L.3
-
11
-
-
0027489766
-
New directions in radionuclide sources for brachytherapy
-
Nath R. New directions in radionuclide sources for brachytherapy. Semin Radiat Oncol 3 (1993) 278-289
-
(1993)
Semin Radiat Oncol
, vol.3
, pp. 278-289
-
-
Nath, R.1
-
12
-
-
0028919251
-
Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM radiation therapy committee task group no. 43
-
Nath R., Anderson L.L., Luxton G., Weaver K.A., Williamson J.F., and Meigooni A.S. Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM radiation therapy committee task group no. 43. Med Phys 22 (1995) 209-234
-
(1995)
Med Phys
, vol.22
, pp. 209-234
-
-
Nath, R.1
Anderson, L.L.2
Luxton, G.3
Weaver, K.A.4
Williamson, J.F.5
Meigooni, A.S.6
-
13
-
-
33646477210
-
-
National Radiological Protection Board. Living with radiation, fifth ed. Chilton, Oxon, NRPB; 1998.
-
-
-
-
14
-
-
31144449060
-
125I prostate brachytherapy as a boost to external beam radiotherapy in locally advanced prostatic cancer: a dosimetric point of view
-
125I prostate brachytherapy as a boost to external beam radiotherapy in locally advanced prostatic cancer: a dosimetric point of view. Radiother Oncol 78 (2006) 47-52
-
(2006)
Radiother Oncol
, vol.78
, pp. 47-52
-
-
Nickers, P.1
Thissen, B.2
Jansen, N.3
Deneufbourg, J.M.4
-
15
-
-
33646479994
-
-
Nuclear Regulatory Commission. NUREG-1556. Consolidated guidance about material licenses, program-specific guidance about medical use licenses. Washington DC: US Nuclear Regulatory Commission, vol. 9; June 2002. p. U-1-U-27.
-
-
-
-
16
-
-
0036680314
-
Prostate cancer radiation dose response: results of the M.D. Anderson phase III randomized trial
-
Pollack A., Zagars G.K., Starkschall G., et al. Prostate cancer radiation dose response: results of the M.D. Anderson phase III randomized trial. Int J Radiat Oncol Biol Phys 53 (2002) 1097-1105
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.53
, pp. 1097-1105
-
-
Pollack, A.1
Zagars, G.K.2
Starkschall, G.3
-
17
-
-
10044258557
-
MR and CT image fusion for postimplant analysis in permanent prostate seed implants
-
Polo A., Cattani F., Vavassori A., et al. MR and CT image fusion for postimplant analysis in permanent prostate seed implants. Int J Radiat Oncol Biol Phys 51 (2004) 31-40
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.51
, pp. 31-40
-
-
Polo, A.1
Cattani, F.2
Vavassori, A.3
-
18
-
-
1842475758
-
Monoterapy for stage T1-T2 prostate cancer: radical prostatectomy, external beam radiotherapy, or permanent seed implantation
-
Potters L., Klein E.A., Kattan M.W., et al. Monoterapy for stage T1-T2 prostate cancer: radical prostatectomy, external beam radiotherapy, or permanent seed implantation. Radiother Oncol 71 (2004) 29-33
-
(2004)
Radiother Oncol
, vol.71
, pp. 29-33
-
-
Potters, L.1
Klein, E.A.2
Kattan, M.W.3
-
20
-
-
4644328634
-
Quality of permanent prostate implants using automated delivery with seedSelectron versus manual insertion of RAPID Strands™
-
Van Gellekom M.P.R., Moerland M.A., Wijrdeman H.K., and Battermann J.J. Quality of permanent prostate implants using automated delivery with seedSelectron versus manual insertion of RAPID Strands™. Radiother Oncol 73 (2004) 49-56
-
(2004)
Radiother Oncol
, vol.73
, pp. 49-56
-
-
Van Gellekom, M.P.R.1
Moerland, M.A.2
Wijrdeman, H.K.3
Battermann, J.J.4
-
21
-
-
0034043918
-
Radical prostatectomy for localized prostate cancer provides durable cancer control with excellent quality of life: a structured debate
-
Walsh P.C. Radical prostatectomy for localized prostate cancer provides durable cancer control with excellent quality of life: a structured debate. J Urol 163 (2000) 1802-1807
-
(2000)
J Urol
, vol.163
, pp. 1802-1807
-
-
Walsh, P.C.1
-
22
-
-
0032891406
-
Ibbott geoffrey-guidance to users of Nycomed Amersham and North American scientific, Inc., I-125 intestitial sources: dosimetry and calibration changes: recommenations of the american association of physicists in medicine radiation therapy committee ad hoc subcommittee on low-energy seed dosimetry
-
Williamson J.F., Coursey B.M., DeWerd L.A., Hanson W.F., and Nath R. Ibbott geoffrey-guidance to users of Nycomed Amersham and North American scientific, Inc., I-125 intestitial sources: dosimetry and calibration changes: recommenations of the american association of physicists in medicine radiation therapy committee ad hoc subcommittee on low-energy seed dosimetry. Med Phys 26 (1999) 570-573
-
(1999)
Med Phys
, vol.26
, pp. 570-573
-
-
Williamson, J.F.1
Coursey, B.M.2
DeWerd, L.A.3
Hanson, W.F.4
Nath, R.5
-
23
-
-
0034891284
-
High dose radiation delivered by intensity modulated conformal radiotherapy improves the outcome of localized prostate cancer
-
Zelefsky M.J., Fuks Z., Hunt M., et al. High dose radiation delivered by intensity modulated conformal radiotherapy improves the outcome of localized prostate cancer. J Urol 166 (2001) 876-881
-
(2001)
J Urol
, vol.166
, pp. 876-881
-
-
Zelefsky, M.J.1
Fuks, Z.2
Hunt, M.3
-
24
-
-
0034266493
-
Postimplantation dosimetric analysis of permanent transperineal prostate implantation: improved dose distributions with an intraoperative computer-optimized conformal planning technique
-
Zelefsky M.J., Yamada Y., Cohen G., et al. Postimplantation dosimetric analysis of permanent transperineal prostate implantation: improved dose distributions with an intraoperative computer-optimized conformal planning technique. Int J Radiat Oncol Biol Phys 48 (2000) 601-608
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.48
, pp. 601-608
-
-
Zelefsky, M.J.1
Yamada, Y.2
Cohen, G.3
-
25
-
-
0037443428
-
Improved conformality and decreased toxicity with intraoperative computer-optimized transperineal ultrasound-guided prostate brachytherapy
-
Zelefsky M.J., Yamada Y., Marion C., et al. Improved conformality and decreased toxicity with intraoperative computer-optimized transperineal ultrasound-guided prostate brachytherapy. Int J Radiat Oncol Biol Phys 55 (2003) 956-963
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.55
, pp. 956-963
-
-
Zelefsky, M.J.1
Yamada, Y.2
Marion, C.3
|