메뉴 건너뛰기




Volumn 60, Issue 4, 2006, Pages 841-843

Complications after plate fixation of phalangeal fractures

Author keywords

Complications; Phalangeal fracture; Plate fixation; Range of motion (ROM); Stiffness

Indexed keywords

ADULT; AGED; COMPLEX REGIONAL PAIN SYNDROME; CORRELATION COEFFICIENT; DISEASE CLASSIFICATION; FEMALE; FRACTURE HEALING; HAND FRACTURE; HAND RADIOGRAPHY; HUMAN; INFECTION; JOINT MOBILITY; JOINT STABILITY; JOINT STIFFNESS; MAJOR CLINICAL STUDY; MALE; MINIMALLY INVASIVE SURGERY; MOBILIZATION; OCCUPATION; OPEN REDUCTION; PHALANX FRACTURE; PLATE FIXATION; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; PROSTHESIS LOOSENING; RANGE OF MOTION; RELIABILITY; RETROSPECTIVE STUDY; REVIEW; SCAR FORMATION; SOFT TISSUE INJURY; SURGICAL TECHNIQUE; TREATMENT OUTCOME; ARTICLE; BONE PLATE; CLASSIFICATION; FINGER PHALANX; FRACTURE; INJURY; JOINT CHARACTERISTICS AND FUNCTIONS; MIDDLE AGED;

EID: 33646472430     PISSN: 00225282     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.ta.0000214887.31745.c4     Document Type: Review
Times cited : (95)

References (14)
  • 1
    • 0034151022 scopus 로고    scopus 로고
    • Operative treatment of metacarpal and phalangeal shaft fractures
    • Kozin SH, Thoder JJ, Lieberman G. Operative treatment of metacarpal and phalangeal shaft fractures. J Am Acad Ortop Surg. 2000;8:111-121.
    • (2000) J Am Acad Ortop Surg , vol.8 , pp. 111-121
    • Kozin, S.H.1    Thoder, J.J.2    Lieberman, G.3
  • 2
    • 0022453296 scopus 로고
    • Rigid fixation of phalangeal and metacarpal fractures
    • Melone CP Jr. Rigid fixation of phalangeal and metacarpal fractures. Othop Clin North Am. 1986;17:421-435.
    • (1986) Othop Clin North Am , vol.17 , pp. 421-435
    • Melone Jr., C.P.1
  • 3
    • 0023091775 scopus 로고
    • Use of a minicondylar plate for metacarpal and phalangeal periarticular injuries
    • Buchler U, Fischer T. Use of a minicondylar plate for metacarpal and phalangeal periarticular injuries. Clin Orthop Relat Res. 1987; 214:53-58.
    • (1987) Clin Orthop Relat Res , vol.214 , pp. 53-58
    • Buchler, U.1    Fischer, T.2
  • 4
    • 0026532396 scopus 로고
    • External fixation of unstable metacarpal and phalangeal fractures
    • Parsons SW, Fitzgerald JA, Shearer JR. External fixation of unstable metacarpal and phalangeal fractures. J Hand Surg. 1992;17B:151-155.
    • (1992) J Hand Surg , vol.17 B , pp. 151-155
    • Parsons, S.W.1    Fitzgerald, J.A.2    Shearer, J.R.3
  • 5
    • 0027458688 scopus 로고
    • Dynamic external finger fixator for fracture dislocation of the proximal interphalangeal joint
    • Inanami H., Ninomiya S, Okutsu I, Tarui T. Dynamic external finger fixator for fracture dislocation of the proximal interphalangeal joint. J Hand Surg [Am]. 1993;18:160-164.
    • (1993) J Hand Surg [Am] , vol.18 , pp. 160-164
    • Inanami, H.1    Ninomiya, S.2    Okutsu, I.3    Tarui, T.4
  • 6
    • 0027155151 scopus 로고
    • Open hand fractures: An analysis of the recovery of active motion and of complications
    • Duncan RW, Freeland AE, Jabaley ME, Meydrech EF. Open hand fractures: an analysis of the recovery of active motion and of complications. J Hand Surg [Am]. 1993;18:387-394.
    • (1993) J Hand Surg [Am] , vol.18 , pp. 387-394
    • Duncan, R.W.1    Freeland, A.E.2    Jabaley, M.E.3    Meydrech, E.F.4
  • 7
    • 0025974083 scopus 로고
    • Unstable phalangeal fractures: Treatment by A.O. screw and plate fixation
    • Pun WK, Chow SP, So YC, et al. Unstable phalangeal fractures: Treatment by A.O. screw and plate fixation. J Hand Surg [Am]. 1991;16:113-117.
    • (1991) J Hand Surg [Am] , vol.16 , pp. 113-117
    • Pun, W.K.1    Chow, S.P.2    So, Y.C.3
  • 8
    • 0032463393 scopus 로고    scopus 로고
    • Complications and range of motion following plate fixation of metacarpal and phalangeal fractures
    • Page SM, Stern PJ. Complications and range of motion following plate fixation of metacarpal and phalangeal fractures. J Hand Surg [Am]. 1998;23:827-832.
    • (1998) J Hand Surg [Am] , vol.23 , pp. 827-832
    • Page, S.M.1    Stern, P.J.2
  • 9
    • 0036125810 scopus 로고    scopus 로고
    • Complications of plate fixation in metacarpal fractures
    • Fusetti C, Meyer H, Borisch N, et al. Complications of plate fixation in metacarpal fractures. J Trauma. 2002;52:535-539.
    • (2002) J Trauma , vol.52 , pp. 535-539
    • Fusetti, C.1    Meyer, H.2    Borisch, N.3
  • 10
    • 0023133412 scopus 로고
    • Complications of plate fixation in the hand skeleton
    • Stern PJ, Wieser MJ, Reilly DG. Complications of plate fixation in the hand skeleton. Clin Orthop. 1987;214:59-65.
    • (1987) Clin Orthop , vol.214 , pp. 59-65
    • Stern, P.J.1    Wieser, M.J.2    Reilly, D.G.3
  • 12
    • 0022624138 scopus 로고
    • Fixation of metacarpal and phalangeal fractures with miniature plates and screws
    • Dabezies EJ, Schutte JP. Fixation of metacarpal and phalangeal fractures with miniature plates and screws. J Hand Surg [Am]. 1986; 11:283-288.
    • (1986) J Hand Surg [Am] , vol.11 , pp. 283-288
    • Dabezies, E.J.1    Schutte, J.P.2
  • 13
    • 0021078234 scopus 로고
    • Functional brace in the treatment of diaphyseal fractures of the proximal phalanges of the last four fingers
    • Thomine JM, Gibon Y, Bendjeddou MS, Biga N. Functional brace in the treatment of diaphyseal fractures of the proximal phalanges of the last four fingers, Ann Chir Main. 1983;2:298-306.
    • (1983) Ann Chir Main , vol.2 , pp. 298-306
    • Thomine, J.M.1    Gibon, Y.2    Bendjeddou, M.S.3    Biga, N.4
  • 14
    • 0037316151 scopus 로고    scopus 로고
    • A prospective randomised controlled study of fixation of long oblique and spiral shaft fractures of the proximal phalanx: Closed reduction and percutaneous Kirschner wiring versus open reduction and lag screw fixation
    • Horton TC, Hatton M, Davis TR. A prospective randomised controlled study of fixation of long oblique and spiral shaft fractures of the proximal phalanx: closed reduction and percutaneous Kirschner wiring versus open reduction and lag screw fixation. J Hand Surg (Br). 2003;28:5-9.
    • (2003) J Hand Surg (Br) , vol.28 , pp. 5-9
    • Horton, T.C.1    Hatton, M.2    Davis, T.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.