메뉴 건너뛰기




Volumn 1281, Issue , 2005, Pages 827-831

CAD/CAM titanium implants for cranioplasty-an evaluation of success and quality of life of 169 consecutive implants with regard to size and location

Author keywords

CAD CAM; Craniectomy; Cranioplasty; Quality of life; Titanium

Indexed keywords


EID: 33646442943     PISSN: 05315131     EISSN: None     Source Type: Book Series    
DOI: 10.1016/j.ics.2005.03.074     Document Type: Article
Times cited : (18)

References (10)
  • 1
    • 0030951321 scopus 로고    scopus 로고
    • One-year outcome after decompressive surgery for massive nondominant hemispheric infarction
    • Carter B.S., et al. One-year outcome after decompressive surgery for massive nondominant hemispheric infarction. Neurosurgery 40 (1997) 1168-1176
    • (1997) Neurosurgery , vol.40 , pp. 1168-1176
    • Carter, B.S.1
  • 2
    • 0030899201 scopus 로고    scopus 로고
    • Cranioplasty: cosmetic or therapeutic?
    • Dujovny M., et al. Cranioplasty: cosmetic or therapeutic?. Surg. Neurol. 47 (1997) 238-241
    • (1997) Surg. Neurol. , vol.47 , pp. 238-241
    • Dujovny, M.1
  • 3
  • 4
    • 0029245366 scopus 로고
    • Prefabricated prostheses for the reconstruction of skull defects
    • Eufinger H., et al. Prefabricated prostheses for the reconstruction of skull defects. Int. J. Oral Maxillofac. Surg. 24 (1995) 104-110
    • (1995) Int. J. Oral Maxillofac. Surg. , vol.24 , pp. 104-110
    • Eufinger, H.1
  • 5
    • 0344269296 scopus 로고
    • Individual prefabricated titanium implants in reconstructive craniofacial surgery: clinical and technical aspects of the first 22 cases
    • Eufinger H., and Wehmöller M. Individual prefabricated titanium implants in reconstructive craniofacial surgery: clinical and technical aspects of the first 22 cases. Plast. Reconstr. Surg. 102 (1988) 300-308
    • (1988) Plast. Reconstr. Surg. , vol.102 , pp. 300-308
    • Eufinger, H.1    Wehmöller, M.2
  • 7
    • 0033169246 scopus 로고    scopus 로고
    • Validation of computer-assisted manufacture of titanium plates for cranioplasty
    • Joffe J.M., et al. Validation of computer-assisted manufacture of titanium plates for cranioplasty. Int. J. Oral Maxillofac. Surg. 28 (1999) 309-313
    • (1999) Int. J. Oral Maxillofac. Surg. , vol.28 , pp. 309-313
    • Joffe, J.M.1
  • 8
    • 0031029806 scopus 로고    scopus 로고
    • Symptomatic patients after craniectomy
    • Schiffer J., et al. Symptomatic patients after craniectomy. Surg. Neurol. 47 (1997) 231-237
    • (1997) Surg. Neurol. , vol.47 , pp. 231-237
    • Schiffer, J.1
  • 10
    • 0029247978 scopus 로고
    • CAD by processing of computed tomography data and CAM of individually designed prostheses
    • Wehmöller M., et al. CAD by processing of computed tomography data and CAM of individually designed prostheses. Int. J. Oral Maxillofac. Surg. 24 (1995) 90-97
    • (1995) Int. J. Oral Maxillofac. Surg. , vol.24 , pp. 90-97
    • Wehmöller, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.