메뉴 건너뛰기




Volumn 55, Issue 5, 2006, Pages 1210-1216

Continuously moving table 3D MRI with lateral frequency-encoding direction

Author keywords

3D; Continuously moving table MRI; Magnetization preparation; Motion; Whole body imaging

Indexed keywords

CHEMICAL SHIFT; ENCODING (SYMBOLS); MAGNETIZATION; MOTION TRACKING; SIGNAL ENCODING;

EID: 33646440710     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.20876     Document Type: Article
Times cited : (14)

References (18)
  • 2
    • 0031647074 scopus 로고    scopus 로고
    • Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and illiac arteries with dynamic manual table translation
    • Earls PJ, DeSena S, Bluemke DA. Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and illiac arteries with dynamic manual table translation. Radiology 1998;209:844-849.
    • (1998) Radiology , vol.209 , pp. 844-849
    • Earls, P.J.1    DeSena, S.2    Bluemke, D.A.3
  • 3
    • 12144276957 scopus 로고    scopus 로고
    • Patient-related navigation tool based on moving bed imaging for interactive MRI
    • New York, NY, USA
    • Bojahr O, Holz D, Rasche V, Renz W. Patient-related navigation tool based on moving bed imaging for interactive MRI. In: Proceedings of the 4th Annual Meeting of ISMRM, New York, NY, USA, 1996. p 1734.
    • (1996) Proceedings of the 4th Annual Meeting of ISMRM , pp. 1734
    • Bojahr, O.1    Holz, D.2    Rasche, V.3    Renz, W.4
  • 4
    • 0031021075 scopus 로고    scopus 로고
    • Total-body MR imaging in as little as 18 seconds
    • Johnson KMR, Leavitt GD, Kayser HWM. Total-body MR imaging in as little as 18 seconds. Radiology 1997;202:262-267.
    • (1997) Radiology , vol.202 , pp. 262-267
    • Johnson, K.M.R.1    Leavitt, G.D.2    Kayser, H.W.M.3
  • 5
    • 0032951860 scopus 로고    scopus 로고
    • Total-body echo-planar MR imaging in the staging of breast cancer: Comparison with conventional methods-early experience
    • Horvath L J, Burtness BA, McCarthy S, Johnson KM. Total-body echo-planar MR imaging in the staging of breast cancer: comparison with conventional methods-early experience. Radiology 1999;211:119-128.
    • (1999) Radiology , vol.211 , pp. 119-128
    • Horvath, L.J.1    Burtness, B.A.2    McCarthy, S.3    Johnson, K.M.4
  • 6
    • 0034979158 scopus 로고    scopus 로고
    • Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study
    • Barkhausen J, Quick HH, Lauenstein T, Goyen M, Ruehm SG, Laub G, Debatin JF, Ladd ME. Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: feasibility study. Radiology 2001;220:252-256.
    • (2001) Radiology , vol.220 , pp. 252-256
    • Barkhausen, J.1    Quick, H.H.2    Lauenstein, T.3    Goyen, M.4    Ruehm, S.G.5    Laub, G.6    Debatin, J.F.7    Ladd, M.E.8
  • 8
    • 0000557592 scopus 로고    scopus 로고
    • Extending the coverage of true volume scans by continuous movement of the subject
    • Philadelphia, PA, USA
    • Dietrich O, Hajnal JV. Extending the coverage of true volume scans by continuous movement of the subject. In: Proceedings of the 7th Annual Meeting of ISMRM, Philadelphia, PA, USA, 1999. p 1653.
    • (1999) Proceedings of the 7th Annual Meeting of ISMRM , pp. 1653
    • Dietrich, O.1    Hajnal, J.V.2
  • 9
    • 0036158390 scopus 로고    scopus 로고
    • Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI
    • Kruger DG, Riederer SJ, Grimm RC, Rossman PJ. Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI. Magn Reson Med 2002;47:224-231.
    • (2002) Magn Reson Med , vol.47 , pp. 224-231
    • Kruger, D.G.1    Riederer, S.J.2    Grimm, R.C.3    Rossman, P.J.4
  • 11
    • 0038778570 scopus 로고    scopus 로고
    • Extended field-of-view imaging with table translation and frequency sweeping
    • Zhu Y, Dumoulin CL. Extended field-of-view imaging with table translation and frequency sweeping. Magn Reson Med 2003;49:1106-1112.
    • (2003) Magn Reson Med , vol.49 , pp. 1106-1112
    • Zhu, Y.1    Dumoulin, C.L.2
  • 12
    • 7544244928 scopus 로고    scopus 로고
    • Floating table isotropic projection (FLIPR) acquisition: A time-resolved 3D method for extended field-of-view MRI during continuous table motion
    • Fain SB, Browning FJ, Polzin JA, Du J, Zhou Y, Block WF, Grist TM, Mistretta CA. Floating table isotropic projection (FLIPR) acquisition: a time-resolved 3D method for extended field-of-view MRI during continuous table motion. Magn Reson Med 2004;52:1093-1102.
    • (2004) Magn Reson Med , vol.52 , pp. 1093-1102
    • Fain, S.B.1    Browning, F.J.2    Polzin, J.A.3    Du, J.4    Zhou, Y.5    Block, W.F.6    Grist, T.M.7    Mistretta, C.A.8
  • 15
    • 33645588897 scopus 로고    scopus 로고
    • Continuous adjustment of calibration values for improved image quality in continuously moving table imaging
    • Kyoto, Japan
    • Shankaranarayanan A, Brittain J. Continuous adjustment of calibration values for improved image quality in continuously moving table imaging. In: Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, Japan, 2004. p 103.
    • (2004) Proceedings of the 12th Annual Meeting of ISMRM , pp. 103
    • Shankaranarayanan, A.1    Brittain, J.2
  • 17
  • 18
    • 26844572829 scopus 로고    scopus 로고
    • Continuously moving table MRI with SENSE: Application in peripheral contrast enhanced MR angiography
    • Hu HH, Madhuranthakam AJ, Kruger DG, Glockner JF, Riederer SJ. Continuously moving table MRI with SENSE: Application in peripheral contrast enhanced MR angiography. Magn Reson Med 2005;54:1025-1031.
    • (2005) Magn Reson Med , vol.54 , pp. 1025-1031
    • Hu, H.H.1    Madhuranthakam, A.J.2    Kruger, D.G.3    Glockner, J.F.4    Riederer, S.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.