메뉴 건너뛰기




Volumn 65, Issue 5, 2006, Pages 342-348

Effect of ethanol/trisodium citrate lock on the mechanical properties of carbothane hemodialysis catheters

Author keywords

Carbothane; Catheter lock; Citrate; Ethanol hemodialysis; Mechanical properties

Indexed keywords

ALCOHOL; CARBOTHANE; CITRATE TRISODIUM; HEPARIN; POLYURETHAN; UNCLASSIFIED DRUG;

EID: 33646419805     PISSN: 03010430     EISSN: None     Source Type: Journal    
DOI: 10.5414/CNP65342     Document Type: Article
Times cited : (37)

References (23)
  • 1
    • 0034185673 scopus 로고    scopus 로고
    • Failure of central vein catheters after prolonged use
    • Agraharkar M 2000 Failure of central vein catheters after prolonged use. Semin Dial 13: 205-206
    • (2000) Semin Dial , vol.13 , pp. 205-206
    • Agraharkar, M.1
  • 2
    • 0037762620 scopus 로고    scopus 로고
    • Ethanol locking as a possible treatment for microbial contamination of long-term central venous catheters
    • Ball PA, Brokenshire E, Parry B, Merrie A, Gillanders L, McIlroy K, Plank L 2003 Ethanol locking as a possible treatment for microbial contamination of long-term central venous catheters. Nutrition 19: 570
    • (2003) Nutrition , vol.19 , pp. 570
    • Ball, P.A.1    Brokenshire, E.2    Parry, B.3    Merrie, A.4    Gillanders, L.5    McIlroy, K.6    Plank, L.7
  • 3
    • 19544385755 scopus 로고    scopus 로고
    • Product information
    • Bard Access Systems Murray Hill, New Jersey, USA
    • Bard Access Systems 2004 Product information. Murray Hill, New Jersey, USA
    • (2004)
  • 4
    • 0032908546 scopus 로고    scopus 로고
    • Management of bacteremia associated with tunneled-cuffed hemodialysis catheters
    • Beathard GA 1999 Management of bacteremia associated with tunneled-cuffed hemodialysis catheters. J Am Soc Nephrol 10: 1045-1049
    • (1999) J Am Soc Nephrol , vol.10 , pp. 1045-1049
    • Beathard, G.A.1
  • 6
    • 0031730215 scopus 로고    scopus 로고
    • Filling hemodialysis catheters in the interdialytic period: Heparin versus citrate versus polygeline: A prospective randomized study
    • Buturovic J, Ponikvar R, Kandus A, Boh M, Klinkmann J, Ivanovich P 1998 Filling hemodialysis catheters in the interdialytic period: heparin versus citrate versus polygeline: a prospective randomized study. Artif Organs 22: 945-947
    • (1998) Artif Organs , vol.22 , pp. 945-947
    • Buturovic, J.1    Ponikvar, R.2    Kandus, A.3    Boh, M.4    Klinkmann, J.5    Ivanovich, P.6
  • 7
    • 23844528204 scopus 로고    scopus 로고
    • The effects of prolonged ethanol exposure on the mechanical properties of polyurethane and silicone catheters used for intravascular access
    • Crnich CJ, Halfmann JA, Crone WC, Maki DG 2005 The effects of prolonged ethanol exposure on the mechanical properties of polyurethane and silicone catheters used for intravascular access. Infect Control Hosp Epidemiol 26: 708-714
    • (2005) Infect Control Hosp Epidemiol , vol.26 , pp. 708-714
    • Crnich, C.J.1    Halfmann, J.A.2    Crone, W.C.3    Maki, D.G.4
  • 8
    • 0042570552 scopus 로고    scopus 로고
    • Ethanol-lock technique in the treatment of bloodstream infections in pediatric oncology patients with broviac catheter
    • Dannenberg C, Bierbach U, Rothe A, Beer J, Korholz D 2003 Ethanol-lock technique in the treatment of bloodstream infections in pediatric oncology patients with broviac catheter. J Pediatr Hematol Oncol 25: 616-621
    • (2003) J Pediatr Hematol Oncol , vol.25 , pp. 616-621
    • Dannenberg, C.1    Bierbach, U.2    Rothe, A.3    Beer, J.4    Korholz, D.5
  • 9
    • 0036063589 scopus 로고    scopus 로고
    • Prevention of tunneled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: A randomized controlled study
    • Dogra GK, Herson H, Hutchison B, Irish AB, Heath CH, Golledge C, Luxton G, Moody H 2002 Prevention of tunneled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: a randomized controlled study. J Am Soc Nephrol 13: 2133-2139
    • (2002) J Am Soc Nephrol , vol.13 , pp. 2133-2139
    • Dogra, G.K.1    Herson, H.2    Hutchison, B.3    Irish, A.B.4    Heath, C.H.5    Golledge, C.6    Luxton, G.7    Moody, H.8
  • 10
    • 0242684598 scopus 로고    scopus 로고
    • Stability and in vitro efficacy of antibiotic-heparin lock solutions potentially useful for treatment of central venous catheter-related sepsis
    • Droste JC, Jeraj HA, MacDonald A, Farrington K 2003 Stability and in vitro efficacy of antibiotic-heparin lock solutions potentially useful for treatment of central venous catheter-related sepsis. J Antimicrob Chemother 51: 849-855
    • (2003) J Antimicrob Chemother , vol.51 , pp. 849-855
    • Droste, J.C.1    Jeraj, H.A.2    MacDonald, A.3    Farrington, K.4
  • 11
    • 0345367419 scopus 로고    scopus 로고
    • Replacement of failing tunneled hemodialysis catheters through pre-existing subcutaneous tunnels: A comparison of catheter function and infection rates for de novo placements and over-the-wire exchanges
    • Duszak R Jr, Haskal ZJ, Thomas-Hawkins C, Soulen MC, Baum RA, Shlansky-Goldberg RD, Cope C 1998 Replacement of failing tunneled hemodialysis catheters through pre-existing subcutaneous tunnels: a comparison of catheter function and infection rates for de novo placements and over-the-wire exchanges. J Vasc Interv Radiol 9: 321-327
    • (1998) J Vasc Interv Radiol , vol.9 , pp. 321-327
    • Duszak Jr., R.1    Haskal, Z.J.2    Thomas-Hawkins, C.3    Soulen, M.C.4    Baum, R.A.5    Shlansky-Goldberg, R.D.6    Cope, C.7
  • 13
    • 85039356097 scopus 로고    scopus 로고
    • Successful use of a 25% alcohol lock solution for prevention of recurrent CVC-related blood stream infection in a patient on home TNA
    • 42nd Interscience Conference on Antimicrobial Agents and Chemotherapy, San Diego, CA, USA
    • Maki D, Crnich C, Safdar N 2002 Successful use of a 25% alcohol lock solution for prevention of recurrent CVC-related blood stream infection in a patient on home TNA. 42nd Interscience Conference on Antimicrobial Agents and Chemotherapy, San Diego, CA, USA
    • (2002)
    • Maki, D.1    Crnich, C.2    Safdar, N.3
  • 14
    • 0030746333 scopus 로고    scopus 로고
    • Catheter-related bacteremia and outcome of attempted catheter salvage in patients undergoing hemodialysis
    • Marr KA, Sexton DJ, Conlon PJ, Corey GR, Schwab SJ, Kirkland KB 1997 Catheter-related bacteremia and outcome of attempted catheter salvage in patients undergoing hemodialysis. Ann Intern Med 127:275-280
    • (1997) Ann Intern Med , vol.127 , pp. 275-280
    • Marr, K.A.1    Sexton, D.J.2    Conlon, P.J.3    Corey, G.R.4    Schwab, S.J.5    Kirkland, K.B.6
  • 15
    • 0030801534 scopus 로고    scopus 로고
    • Polyurethane central venous catheters, hydrochloric acid and 70% ethanol: A safety evaluation
    • McHugh GJ, Wild DJ, Havill JH 1997 Polyurethane central venous catheters, hydrochloric acid and 70% ethanol: a safety evaluation. Anaesth Intensive Care 25: 350-353
    • (1997) Anaesth Intensive Care , vol.25 , pp. 350-353
    • McHugh, G.J.1    Wild, D.J.2    Havill, J.H.3
  • 17
    • 2442462122 scopus 로고    scopus 로고
    • Treatment of catheter-related bacteraemia with an antibiotic lock protocol: Effect of bacterial pathogen
    • Poole CV, Carlton D, Bimbo L, Allon M 2004 Treatment of catheter-related bacteraemia with an antibiotic lock protocol: effect of bacterial pathogen. Nephrol Dial Transplant 19: 1237-1244
    • (2004) Nephrol Dial Transplant , vol.19 , pp. 1237-1244
    • Poole, C.V.1    Carlton, D.2    Bimbo, L.3    Allon, M.4
  • 18
    • 0031802118 scopus 로고    scopus 로고
    • Treatment of infected tunneled venous access hemodialysis catheters with guidewire exchange
    • Robinson D, Suhocki P, Schwab SJ 1998 Treatment of infected tunneled venous access hemodialysis catheters with guidewire exchange. Kidney Int 53: 1792-1794
    • (1998) Kidney Int , vol.53 , pp. 1792-1794
    • Robinson, D.1    Suhocki, P.2    Schwab, S.J.3
  • 19
    • 0032739952 scopus 로고    scopus 로고
    • Bacteremia associated with tunneled, cuffed hemodialysis catheters
    • Saad TF 1999 Bacteremia associated with tunneled, cuffed hemodialysis catheters. Am J Kidney Dis 34: 1114-1124
    • (1999) Am J Kidney Dis , vol.34 , pp. 1114-1124
    • Saad, T.F.1
  • 21
    • 0035162149 scopus 로고    scopus 로고
    • Two years' experience with Dialock and CLS (a new antimicrobial lock solution)
    • Sodemann K, Polaschegg HD, Feldmer B 2001 Two years' experience with Dialock and CLS (a new antimicrobial lock solution). Blood Purif 19: 251-254
    • (2001) Blood Purif , vol.19 , pp. 251-254
    • Sodemann, K.1    Polaschegg, H.D.2    Feldmer, B.3
  • 22
    • 0003854849 scopus 로고    scopus 로고
    • FDA Issues Warning on Tricitrasol Dialysis Catheter Anticoagulant
    • US Food and Drug Administration Food and Drug Administration Talk Paper. T 00-16
    • US Food and Drug Administration 2000 FDA Issues Warning on Tricitrasol Dialysis Catheter Anticoagulant. Food and Drug Administration Talk Paper. T 00-16
    • (2000)
  • 23
    • 0037760153 scopus 로고    scopus 로고
    • Manufacturer and User Facility Device Experience Database (MAUDE)
    • US Food and Drug Administration, Department of Health and Human Services, Center for Devices and Radiographical Health Rockville, MD
    • US Food and Drug Administration, Department of Health and Human Services, Center for Devices and Radiographical Health 2005 Manufacturer and User Facility Device Experience Database (MAUDE). Rockville, MD
    • (2005)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.