메뉴 건너뛰기




Volumn 23, Issue 5, 2006, Pages 652-661

A fast and highly automated approach to myocardial motion analysis using phase contrast magnetic resonance imaging

Author keywords

Cardiovascular system; Image analysis; Kinematics; Magnetic resonance imaging; Velocity mapping

Indexed keywords

ALGORITHM; ARTICLE; CONTRAST ENHANCEMENT; CONTROLLED STUDY; HEART FUNCTION; HEART VENTRICLE WALL MOTION; HISTOGRAM; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; KINEMATICS; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SIGNAL NOISE RATIO; VALIDATION STUDY; VELOCITY;

EID: 33646186816     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20565     Document Type: Article
Times cited : (18)

References (41)
  • 1
  • 2
    • 0024318208 scopus 로고
    • MR imaging of motion with spatial modulation of magnetization
    • Axel L, Dougherty L. MR imaging of motion with spatial modulation of magnetization. Radiology 1989;171:841-845.
    • (1989) Radiology , vol.171 , pp. 841-845
    • Axel, L.1    Dougherty, L.2
  • 3
    • 0023737101 scopus 로고
    • Human-heart-tagging with MR imaging-a method for noninvasive assessment of myocardial motion
    • Zerhouni EA, Parish M, Rogers WJ, Yang A. Shapiro EP. Human-heart-tagging with MR imaging-a method for noninvasive assessment of myocardial motion. Radiology 1988;169:59-63.
    • (1988) Radiology , vol.169 , pp. 59-63
    • Zerhouni, E.A.1    Parish, M.2    Rogers, W.J.3    Yang, A.4    Shapiro, E.P.5
  • 5
    • 0029029302 scopus 로고
    • Three-dimensional myocardial deformations: Calculation with displacement field fitting to tagged MR images
    • O'Dell WG, Moore CC, Hunter WC, Zerhouni EA, McVeigh E. Three-dimensional myocardial deformations: calculation with displacement field fitting to tagged MR images. Radiology 1995;195:829-835.
    • (1995) Radiology , vol.195 , pp. 829-835
    • O'Dell, W.G.1    Moore, C.C.2    Hunter, W.C.3    Zerhouni, E.A.4    McVeigh, E.5
  • 6
    • 0029879895 scopus 로고    scopus 로고
    • MRI of myocardial function: Motion tracking techniques
    • McVeigh E. MRI of myocardial function: Motion tracking techniques. J Magn Reson Imaging 1996;14:137-150.
    • (1996) J Magn Reson Imaging , vol.14 , pp. 137-150
    • McVeigh, E.1
  • 7
    • 0033659658 scopus 로고    scopus 로고
    • Investigating intrinsic myocardial mechanics: The role of MR tagging, velocity phase mapping and diffusion imaging
    • Masood S, Yang G, Penell DJ. Firmin DN. Investigating intrinsic myocardial mechanics: the role of MR tagging, velocity phase mapping and diffusion imaging. J Magn Reson Imaging 2000;12:873-883.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 873-883
    • Masood, S.1    Yang, G.2    Penell, D.J.3    Firmin, D.N.4
  • 10
    • 0026698614 scopus 로고
    • Magnetic resonance imaging of myocardial kinematics. Techniques to detect, localize and quantify strain rates of the active human myocardium
    • van Wedeen J. Magnetic resonance imaging of myocardial kinematics. Techniques to detect, localize and quantify strain rates of the active human myocardium. Magn Reson Med 1992;27:52-67.
    • (1992) Magn Reson Med , vol.27 , pp. 52-67
    • Van Wedeen, J.1
  • 11
    • 0029740814 scopus 로고    scopus 로고
    • Three-dimensional strain-rate imaging
    • Robson MD, Constable RT. Three-dimensional strain-rate imaging. Magn Reson Med 1996;36:537-546.
    • (1996) Magn Reson Med , vol.36 , pp. 537-546
    • Robson, M.D.1    Constable, R.T.2
  • 12
    • 0032770117 scopus 로고    scopus 로고
    • Myocardial velocity gradient imaging by phase contrast MRI with application to regional function in myocardial ischemia
    • Arai AE, Gaither III CC, Epstein FH, Balaban RS, Wolff SD. Myocardial velocity gradient imaging by phase contrast MRI with application to regional function in myocardial ischemia. Magn Reson in Med 1999;42:98-109.
    • (1999) Magn Reson in Med , vol.42 , pp. 98-109
    • Arai, A.E.1    Gaither III, C.C.2    Epstein, F.H.3    Balaban, R.S.4    Wolff, S.D.5
  • 14
    • 0028239979 scopus 로고
    • Development and evaluation of tracking algorithms for cardiac wall motion analysis using phase velocity MR imaging
    • Constable RT, Rath KM, Sinusas AJ, Gore JC. Development and evaluation of tracking algorithms for cardiac wall motion analysis using phase velocity MR imaging. Magn Reson Med 1994;32:33-42.
    • (1994) Magn Reson Med , vol.32 , pp. 33-42
    • Constable, R.T.1    Rath, K.M.2    Sinusas, A.J.3    Gore, J.C.4
  • 15
    • 0029301143 scopus 로고
    • Tracking of cyclic motion using phase contrast cine MRI velocity data
    • Pelc NJ, Drangova M, Pelc LR, et al. Tracking of cyclic motion using phase contrast cine MRI velocity data. J Magn Reson Imaging 1995;5:339-345.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 339-345
    • Pelc, N.J.1    Drangova, M.2    Pelc, L.R.3
  • 16
    • 1842869922 scopus 로고    scopus 로고
    • Quantification of vessel wall cyclic strain using phase contrast magnetic resonance imaging
    • Draney MR, Herfkens RJ, Hughes TJR, et al. Quantification of vessel wall cyclic strain using phase contrast magnetic resonance imaging. Ann Biomed Eng 2002;30:1033-1045.
    • (2002) Ann Biomed Eng , vol.30 , pp. 1033-1045
    • Draney, M.R.1    Herfkens, R.J.2    Hughes, T.J.R.3
  • 17
    • 0008043128 scopus 로고
    • Tracking myocardial deformation using spatially constrained velocities
    • Bizais Y, Barilot C, Paola RD, editors. Norwell, MA: Kluwer Academic Publishers
    • Meyer FG, Constable T, Sinusas AJ, Duncan JS. Tracking myocardial deformation using spatially constrained velocities. In: Bizais Y, Barilot C, Paola RD, editors. Information processing in medical imaging. Norwell, MA: Kluwer Academic Publishers: 1995. p 177-188.
    • (1995) Information Processing in Medical Imaging , pp. 177-188
    • Meyer, F.G.1    Constable, T.2    Sinusas, A.J.3    Duncan, J.S.4
  • 19
    • 0030216891 scopus 로고    scopus 로고
    • Tracking myocardial deformation using phase contrast MR velocity fields: A stochastic approach
    • Meyer FG, Constable T, Sinusas AJ, Duncan JS. Tracking myocardial deformation using phase contrast MR velocity fields: a stochastic approach. IEEE Trans Med Imaging 1996;15:453-465.
    • (1996) IEEE Trans Med Imaging , vol.15 , pp. 453-465
    • Meyer, F.G.1    Constable, T.2    Sinusas, A.J.3    Duncan, J.S.4
  • 20
    • 0029881362 scopus 로고    scopus 로고
    • Fourier tracking of myocardial motion using cine-PC data
    • Zhu Y, Drangova M, Pelc NJ. Fourier tracking of myocardial motion using cine-PC data. Magn Reson Med 1996;35:471-480.
    • (1996) Magn Reson Med , vol.35 , pp. 471-480
    • Zhu, Y.1    Drangova, M.2    Pelc, N.J.3
  • 21
    • 0031283424 scopus 로고    scopus 로고
    • Estimation of deformation gradient and strain from cine-PC velocity data
    • Zhu Y, Drangova M, Pelc NJ. Estimation of deformation gradient and strain from cine-PC velocity data. IEEE Trans Med Imaging 1997;16:840-851.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 840-851
    • Zhu, Y.1    Drangova, M.2    Pelc, N.J.3
  • 22
    • 0031771410 scopus 로고    scopus 로고
    • In vitro verification of myocardial motion from phase contrast velocity data
    • Drangova M, Zhu Y, Bowman B, Pelc NJ. In vitro verification of myocardial motion from phase contrast velocity data. Magn Reson Imaging 1998;16:863-870.
    • (1998) Magn Reson Imaging , vol.16 , pp. 863-870
    • Drangova, M.1    Zhu, Y.2    Bowman, B.3    Pelc, N.J.4
  • 23
    • 0032904226 scopus 로고    scopus 로고
    • Three-dimensional motion tracking with volumetric phase contrast MR velocity imaging
    • Zhu Y, Pelc NJ. Three-dimensional motion tracking with volumetric phase contrast MR velocity imaging. J Magn Reson Imaging 1999; 9:111-118.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 111-118
    • Zhu, Y.1    Pelc, N.J.2
  • 24
    • 0033153753 scopus 로고    scopus 로고
    • A spatiotemporal model of cyclic kinematics and its application to analyzing nonrigid motion with MR velocity images
    • Zhu Y, Pelc NJ, A spatiotemporal model of cyclic kinematics and its application to analyzing nonrigid motion with MR velocity images. IEEE Trans Med Imaging 1999;18:557-569.
    • (1999) IEEE Trans Med Imaging , vol.18 , pp. 557-569
    • Zhu, Y.1    Pelc, N.J.2
  • 25
    • 0033093565 scopus 로고    scopus 로고
    • DENSE: Displacement encoding with stimulated echoes in cardiac functional MRI
    • Aletras AH, Ding S, Balaban RS, DENSE: displacement encoding with stimulated echoes in cardiac functional MRI. J Magn Reson Imaging 1999;137:247-252.
    • (1999) J Magn Reson Imaging , vol.137 , pp. 247-252
    • Aletras, A.H.1    Ding, S.2    Balaban, R.S.3
  • 27
    • 0034345496 scopus 로고    scopus 로고
    • Computer vision, pattern recognition and image processing in left ventricle segmentation: The last 50 years
    • Suri JS. Computer vision, pattern recognition and image processing in left ventricle segmentation: the last 50 years. Pattern Anal Appl 2000;3:209-242.
    • (2000) Pattern Anal Appl , vol.3 , pp. 209-242
    • Suri, J.S.1
  • 29
    • 0037516834 scopus 로고    scopus 로고
    • 3-D active appearance models: Segmentation of cardiac MR and ultrasound images
    • Mitchell SC, Bosch JG, Boudewijn PF, et al. 3-D active appearance models: segmentation of cardiac MR and ultrasound images. IEEE Trans Med Imaging 2002;21:1167-1178.
    • (2002) IEEE Trans Med Imaging , vol.21 , pp. 1167-1178
    • Mitchell, S.C.1    Bosch, J.G.2    Boudewijn, P.F.3
  • 30
    • 0000142472 scopus 로고
    • Procrustes methods in the statistical analysis of shape
    • Goodall C. Procrustes methods in the statistical analysis of shape. J R Stat Soc Ser B Stat Methodol 1991;53:285-339.
    • (1991) J R Stat Soc Ser B Stat Methodol , vol.53 , pp. 285-339
    • Goodall, C.1
  • 32
    • 0031404171 scopus 로고    scopus 로고
    • Effects of artifacts due to flowing blood reproducibility of phase-contrast measurements of myocardial motion
    • Drangova M, Zhu Y, Pelc NJ. Effects of artifacts due to flowing blood reproducibility of phase-contrast measurements of myocardial motion. J Magn Reson Imaging 1997;7:664-668.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 664-668
    • Drangova, M.1    Zhu, Y.2    Pelc, N.J.3
  • 33
    • 0022438066 scopus 로고
    • Cardiac pumping and function of the ventricular septum
    • Lundbāck S. Cardiac pumping and function of the ventricular septum. Acta Physiol Scand Suppl 1986;550:1-101.
    • (1986) Acta Physiol Scand Suppl , vol.550 , pp. 1-101
    • Lundback, S.1
  • 34
    • 0031756401 scopus 로고    scopus 로고
    • Real-time strain rate imaging of the left ventricle by ultrasound
    • Heimdal A, Stoylen A, Torp H, Skjaerpe T. Real-time strain rate imaging of the left ventricle by ultrasound. J Am Soc Echocardiogr 1998;11:1013-1019.
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 1013-1019
    • Heimdal, A.1    Stoylen, A.2    Torp, H.3    Skjaerpe, T.4
  • 35
    • 0035062389 scopus 로고    scopus 로고
    • Assessment of regional long-axis function during dobutamine echocardiography
    • Cain P, Marwick T, Case C, et al. Assessment of regional long-axis function during dobutamine echocardiography. Clin Sci 2001;85: 423-432.
    • (2001) Clin Sci , vol.85 , pp. 423-432
    • Cain, P.1    Marwick, T.2    Case, C.3
  • 36
    • 0003428840 scopus 로고    scopus 로고
    • Mineola, NY: Dover Publications: 187 p
    • Chadwick P. Continuum mechanics. Mineola, NY: Dover Publications: 1999. 187 p.
    • (1999) Continuum Mechanics
    • Chadwick, P.1
  • 37
    • 0036770732 scopus 로고    scopus 로고
    • Virtual tagging: Numerical considerations and phantom validation
    • Masood S, Gao J, Yang G. Virtual tagging: numerical considerations and phantom validation. IEEE Trans Med Imaging 2002;21: 1123-1131.
    • (2002) IEEE Trans Med Imaging , vol.21 , pp. 1123-1131
    • Masood, S.1    Gao, J.2    Yang, G.3
  • 41
    • 12244274310 scopus 로고    scopus 로고
    • Time-resolved three-dimensional phase-contrast MRI
    • Markl M, Chan FP, Alley MT, et al. Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging 2003;17:499-506.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 499-506
    • Markl, M.1    Chan, F.P.2    Alley, M.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.