메뉴 건너뛰기




Volumn 2005, Issue , 2005, Pages 672-682

Evaluation of the failure in the Texas Genco W. A. Parish Unit #8 cold reheat line

Author keywords

[No Author keywords available]

Indexed keywords

COLD REHEAT (CRH) STEAM LINE; METALLOGRAPHIC EXAMINATIONS; RELIANT RESOURCES; STRESS ENGINEERING SERVICES;

EID: 33646173393     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (6)
  • 1
    • 33646187887 scopus 로고    scopus 로고
    • 2001 ASME boiler & pressure vessel code
    • Section VIII, Division 3, The American Society of Mechanical Engineers, New York, New York, 2003 Addenda, July 1, 2003
    • ASME (2001), 2001 ASME Boiler & Pressure Vessel Code, Section VIII, Division 3, Alternative Rules for the Design of High Pressure Vessels, The American Society of Mechanical Engineers, New York, New York, 2003 Addenda, July 1, 2003.
    • (2001) Alternative Rules for the Design of High Pressure Vessels
  • 2
    • 33646177632 scopus 로고    scopus 로고
    • 2001 ASME boiler & pressure vessel code
    • Section VIII, Division 2, The American Society of Mechanical Engineers, New York, New York, 2003 Addenda, July 1, 2003
    • ASME (2001), 2001 ASME Boiler & Pressure Vessel Code, Section VIII, Division 2, Alternative Rules, The American Society of Mechanical Engineers, New York, New York, 2003 Addenda, July 1, 2003.
    • (2001) Alternative Rules
  • 3
    • 0003455543 scopus 로고    scopus 로고
    • Krieger Publishing Company, Malabar, Florida, 2001
    • Blevins, R.D. (2001), Flow Induced Vibration, Second Edition, Krieger Publishing Company, Malabar, Florida, 2001, pages 384-392.
    • (2001) Flow Induced Vibration, Second Edition , pp. 384-392
    • Blevins, R.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.