메뉴 건너뛰기




Volumn 26, Issue 3, 2006, Pages 164-170

Ride-through control strategy of a doubly fed induction generator for symmetrical grid fault

Author keywords

Doubly fed induction generators; Grid fault; PWM converter; Ride through control; Symmetrical fault; Wind power generation

Indexed keywords

ELECTRIC CONVERTERS; ELECTRIC EXCITATION; ELECTRIC POWER GENERATION; MAGNETIC FLUX; PULSE WIDTH MODULATION; SHORT CIRCUIT CURRENTS; WIND POWER;

EID: 33646127584     PISSN: 02588013     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (53)

References (15)
  • 1
    • 0344899091 scopus 로고    scopus 로고
    • Studies on excitation control of power system voltage oriented for doubly fed generators connected to an infinite bus
    • Li Hui, Yang Shunchang, Liao Yong. Studies on excitation control of power system voltage oriented for doubly fed generators connected to an infinite bus[J]. Proceedings of the CSEE, 2003, 23(8): 159-162.
    • (2003) Proceedings of the CSEE , vol.23 , Issue.8 , pp. 159-162
    • Li, H.1    Yang, S.2    Liao, Y.3
  • 2
    • 1542331746 scopus 로고    scopus 로고
    • Study on excitation control of VSCF doubly fed wind power generator
    • Lin Chengwu, Wang Fengxiang, Yao Xingjia. Study on excitation control of VSCF doubly fed wind power generator[J]. Proceedings of the CSEE, 2003, 23(11): 122-125.
    • (2003) Proceedings of the CSEE , vol.23 , Issue.11 , pp. 122-125
    • Lin, C.1    Wang, F.2    Yao, X.3
  • 3
    • 2442695566 scopus 로고    scopus 로고
    • Study on the no-load cutting-in control of the Variable-Speed-Constant-Frequency (VSCF) wind-power generator
    • Liu Qihui, He Yikang, Bian Songjiang. Study on the no-load cutting-in control of the Variable-Speed-Constant-Frequency (VSCF) wind-power generator[J]. Proceedings of the CSEE, 2004, 24(3): 6-11.
    • (2004) Proceedings of the CSEE , vol.24 , Issue.3 , pp. 6-11
    • Liu, Q.1    He, Y.2    Bian, S.3
  • 4
    • 2942718967 scopus 로고    scopus 로고
    • Analysis and elimination method of harmonics produced by forward voltage drop of ACEG excitation power source
    • Liao Yong, Yao Jun, Yang Shunchang. Analysis and elimination method of harmonics produced by forward voltage drop of ACEG excitation power source[J]. Proceedings of the CSEE, 2004, 24(4): 151-156.
    • (2004) Proceedings of the CSEE , vol.24 , Issue.4 , pp. 151-156
    • Liao, Y.1    Yao, J.2    Yang, S.3
  • 5
    • 3242742309 scopus 로고    scopus 로고
    • Modelling and dynamic simulation of variable wind turbine with large capacity
    • Li Jing, Song Jiahua, Wang Shengwei. Modelling and dynamic simulation of variable wind turbine with large capacity[J]. Proceedings of the CSEE, 2004, 24(6): 100-105.
    • (2004) Proceedings of the CSEE , vol.24 , Issue.6 , pp. 100-105
    • Li, J.1    Song, J.2    Wang, S.3
  • 7
    • 0036957418 scopus 로고    scopus 로고
    • Analysis of harmonic transfer in an AC excited generator including speed ripple
    • Spain
    • Liao Y, Xiang D, Ran L, et al. Analysis of harmonic transfer in an AC excited generator including speed ripple[C]. IECON 02, Spain, 2002. 1162-1166.
    • (2002) IECON 02 , pp. 1162-1166
    • Liao, Y.1    Xiang, D.2    Ran, L.3
  • 8
    • 33646163727 scopus 로고    scopus 로고
    • Guidance note for the connection of wind farms
    • Scottish: Issue No.2.2.2, SP Transmission and Distribution, Hydro-Electric
    • Dallachy J L, Tait I. Guidance note for the connection of wind farms[R]. Scottish: Issue No.2.2.2, SP Transmission and Distribution, Hydro-Electric, 2002.
    • (2002)
    • Dallachy, J.L.1    Tait, I.2
  • 9
    • 0038359393 scopus 로고    scopus 로고
    • Comparison of fixed speed and doubly fed induction wind turbines during power system disturbances
    • Holdsworth L, Wu X, Ekanayake J, et al. Comparison of fixed speed and doubly fed induction wind turbines during power system disturbances[J]. IEE Proc. GTD, 2003, 150(3): 343-352.
    • (2003) IEE Proc. GTD , vol.150 , Issue.3 , pp. 343-352
    • Holdsworth, L.1    Wu, X.2    Ekanayake, J.3
  • 11
    • 12744262671 scopus 로고    scopus 로고
    • Evaluation of current control methods for wind turbines using doubly-fed induction machines
    • Petersson A, Harnefors L, Thiringer T. Evaluation of current control methods for wind turbines using doubly-fed induction machines[J]. IEEE Trans. on Power Electronics, 2005, 20(1): 227-235.
    • (2005) IEEE Trans. on Power Electronics , vol.20 , Issue.1 , pp. 227-235
    • Petersson, A.1    Harnefors, L.2    Thiringer, T.3
  • 12
    • 33646162938 scopus 로고    scopus 로고
    • DFIG control performance under fault conditions for offshore wind applications
    • Turin, Italy
    • Pannell G., Atkinson D, Kemsley R, et al. DFIG control performance under fault conditions for offshore wind applications[C]. CIRED Conf., Turin, Italy, 2005.
    • (2005) CIRED Conf.
    • Pannell, G.1    Atkinson, D.2    Kemsley, R.3
  • 14
    • 0030146394 scopus 로고    scopus 로고
    • Doubly fed induction generator using back-to-back converters and its application to variable-speed wind-energy generation
    • Pena R, Clare J, Asher G.. Doubly fed induction generator using back-to-back converters and its application to variable-speed wind-energy generation[J]. IEE Proceedings-Electric Power Applications, 1996, 143(3): 231-241.
    • (1996) IEE Proceedings-Electric Power Applications , vol.143 , Issue.3 , pp. 231-241
    • Pena, R.1    Clare, J.2    Asher, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.