메뉴 건너뛰기




Volumn 39, Issue 4, 2006, Pages 391-395

Heparin interference in whole blood sodium measurements in a pediatric setting

Author keywords

Blood gas analysis; Blood specimen collection; Heparin; Hyponatremia; Pediatrics; Sodium; Syringes

Indexed keywords

ELECTROLYTE; HEPARIN; LITHIUM DERIVATIVE; SODIUM ION;

EID: 33646086962     PISSN: 00099120     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2005.12.006     Document Type: Article
Times cited : (16)

References (15)
  • 1
    • 0022381678 scopus 로고
    • Facilitated determination of ionized calcium
    • Urban P., Buchmann B., and Scheidegger D. Facilitated determination of ionized calcium. Clin. Chem. 31 (1985) 264-266
    • (1985) Clin. Chem. , vol.31 , pp. 264-266
    • Urban, P.1    Buchmann, B.2    Scheidegger, D.3
  • 2
    • 0022344701 scopus 로고
    • Errors due to heparin in the estimation of plasma sodium and potassium concentrations
    • Shek C.C., and Swaminathan R. Errors due to heparin in the estimation of plasma sodium and potassium concentrations. Intensive Care Med. 11 (1985) 309-311
    • (1985) Intensive Care Med. , vol.11 , pp. 309-311
    • Shek, C.C.1    Swaminathan, R.2
  • 4
    • 0028347826 scopus 로고
    • Use of novel preparations of heparin to eliminate interference in ionized calcium measurements: have all the problems been solved?
    • Toffaletti J. Use of novel preparations of heparin to eliminate interference in ionized calcium measurements: have all the problems been solved?. Clin. Chem. 40 (1994) 508-509
    • (1994) Clin. Chem. , vol.40 , pp. 508-509
    • Toffaletti, J.1
  • 5
    • 0022508012 scopus 로고
    • Interference from heparin in commercial heparinised tubes in the measurement of plasma sodium by ion selective electrode: a note of caution
    • Mann S.W., and Green A. Interference from heparin in commercial heparinised tubes in the measurement of plasma sodium by ion selective electrode: a note of caution. Ann. Clin. Biochem. 23 (1986) 355-356
    • (1986) Ann. Clin. Biochem. , vol.23 , pp. 355-356
    • Mann, S.W.1    Green, A.2
  • 6
    • 0028351186 scopus 로고
    • Bias of ionized calcium results from blood gas syringes
    • Swanson J.R., Heeter C., Limbocker M., and Sullivan M. Bias of ionized calcium results from blood gas syringes. Clin. Chem. 40 (1994) 669-670
    • (1994) Clin. Chem. , vol.40 , pp. 669-670
    • Swanson, J.R.1    Heeter, C.2    Limbocker, M.3    Sullivan, M.4
  • 7
    • 0025998082 scopus 로고
    • Dry electrolyte-balanced heparinized syringes evaluated for determining ionized calcium and other electrolytes in whole blood
    • Toffaletti J., Ernst P., Hunt P., and Abrams B. Dry electrolyte-balanced heparinized syringes evaluated for determining ionized calcium and other electrolytes in whole blood. Clin. Chem. 37 (1991) 1730-1733
    • (1991) Clin. Chem. , vol.37 , pp. 1730-1733
    • Toffaletti, J.1    Ernst, P.2    Hunt, P.3    Abrams, B.4
  • 8
    • 0020131456 scopus 로고
    • Sodium results for urine with the Beckman electrolyte 2 ion-selective electrolyte analyzer are dependent on potassium concentration
    • Harff G.A. Sodium results for urine with the Beckman electrolyte 2 ion-selective electrolyte analyzer are dependent on potassium concentration. Clin. Chem. 28 (1982) 1232-1233
    • (1982) Clin. Chem. , vol.28 , pp. 1232-1233
    • Harff, G.A.1
  • 9
    • 0027259030 scopus 로고
    • Incomplete recovery of sodium determined in direct potentiometry in blood samples added with heparin salts
    • Zoppi F., Guagnellini E., and Manzoni A. Incomplete recovery of sodium determined in direct potentiometry in blood samples added with heparin salts. Scand. J. Clin. Lab. Invest. 53 (1993) 529-537
    • (1993) Scand. J. Clin. Lab. Invest. , vol.53 , pp. 529-537
    • Zoppi, F.1    Guagnellini, E.2    Manzoni, A.3
  • 10
    • 0027320688 scopus 로고
    • Ion effects in measurement of sodium and ionized calcium in direct potentiometry
    • Zoppi F., Guagnellini E., and Manzoni A. Ion effects in measurement of sodium and ionized calcium in direct potentiometry. Scand. J. Clin. Lab. Invest. 53 (1993) 521-527
    • (1993) Scand. J. Clin. Lab. Invest. , vol.53 , pp. 521-527
    • Zoppi, F.1    Guagnellini, E.2    Manzoni, A.3
  • 12
    • 0032832856 scopus 로고    scopus 로고
    • High concentrations of lithium heparin decrease measured serum sodium in some analyzers
    • Vuillaume I., Penet S., Rakza T., Storme L., Kacet N., Lequien P., and Rousseaux J. High concentrations of lithium heparin decrease measured serum sodium in some analyzers. Clin. Chem. 45 (1999) 1880-1881
    • (1999) Clin. Chem. , vol.45 , pp. 1880-1881
    • Vuillaume, I.1    Penet, S.2    Rakza, T.3    Storme, L.4    Kacet, N.5    Lequien, P.6    Rousseaux, J.7
  • 14
    • 0028280984 scopus 로고
    • Interference of zinc heparin anticoagulant in determination of plasma magnesium
    • Wilhite T.R., Smith C.H., and Landt M. Interference of zinc heparin anticoagulant in determination of plasma magnesium. Clin. Chem. 40 (1994) 848-849
    • (1994) Clin. Chem. , vol.40 , pp. 848-849
    • Wilhite, T.R.1    Smith, C.H.2    Landt, M.3
  • 15
    • 0028931539 scopus 로고
    • Specific heparin preparations interfere with the simultaneous measurement of ionized magnesium and ionized calcium
    • Lyon M.E., Bremner D., Laha T., Malik S., Henderson P.J., and Kenny M.A. Specific heparin preparations interfere with the simultaneous measurement of ionized magnesium and ionized calcium. Clin. Biochem. 28 (1995) 79-84
    • (1995) Clin. Biochem. , vol.28 , pp. 79-84
    • Lyon, M.E.1    Bremner, D.2    Laha, T.3    Malik, S.4    Henderson, P.J.5    Kenny, M.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.